32 resultados para Performance levels
Resumo:
The performance of an air-cycle refrigeration unit for road transport, which had been previously reported, was analysed in detail and compared with the original design model and an equivalent Thermo King SL200 vapour-cycle refrigeration unit. Poor heat exchanger performance was found to be the major contributor to low coefficient of performance values. Using state-of-the-art, but achievable performance levels for turbomachinery and heat exchangers, the performance of an optimised air-cycle refrigeration unit for the same application was predicted. The power requirement of the optimised air-cycle unit was 7% greater than the equivalent vapour-cycle unit at full-load operation. However, at part-load operation the air-cycle unit was estimated to absorb 35% less power than the vapour-cycle unit. The analysis demonstrated that the air-cycle system could potentially match the overall fuel consumption of the vapour-cycle transport refrigeration unit, while delivering the benefit of a completely refrigerant free system.
Resumo:
While on site measurement of air permeability provides a useful approach for assessing the likely long term durability of concrete structures, no existing test method is capable of effectively determining the relative permeability of high performance concrete (HPC). Lack of instrument sensitivity and the influence of concrete moisture are proposed as two key reasons for this phenomenon. With limited systematic research carried out in this area to date, the aim if this study was to investigate the influence of instrument sensitivity and moisture condition on air permeability measurements for both normal concrete and HPC. To achieve a range of moisture conditions, samples were dried initially for between one and 5 weeks and then sealed in polythene sheeting and stored in an oven at 50 C to internally distribute moisture evenly. Moisture distribution was determined throughout using relative humidity probe and electrical resistance measurements. Concrete air permeability was subsequently measured using standardised air permeability (Autoclam) and water penetration (BS EN: 12390-8) tests to assess differences between the HPCs tested in this study. It was found that for both normal and high performance concrete, the influence of moisture on Autoclam air permeability results could be eliminated by pre-drying (50 ± 1 C, RH 35%) specimens for 3 weeks. While drying for 5 weeks alone was found not to result in uniform internal moisture distributions, this state was achieved by exposing specimens to a further 3 weeks of sealed pre-conditioning at 50 ± 1 C. While the Autoclam test was not able to accurately identify relative HPC quality due to low sensitivity at associated performance levels, an effective preconditioning procedure to obtain reliable air permeability of HPC concretes was identified. © 2013 The Authors
Resumo:
Background & Aims: Wide between-center variation in adenoma detection rates (ADRs) was observed in the U.K. Flexible Sigmoidoscopy Screening Trial (overall, 12.1%; range, 8.6%-15.9%; P <0.0001). The aim of this study was to determine whether the observed differences could be attributed to varying performance by endoscopists, to examine the effect of experience on performance, and to identify an attainable, standard ADR to which endoscopists could aspire.
Methods: Thirteen medical endoscopists, one per trial center, each performed about 3000 examinations (200 per month) using the same equipment and protocol. Overall and monthly ADRs were compared using multivariable logistic regression.
Results: Differences in ADRs were not explained by patient characteristics, incidence of colorectal cancer in the local population, or the endoscopists' medical specialty or previous experience. Average ADRs increased significantly with screening experience (up to 400 examinations). Endoscopists were classified as higher, intermediate, or lower adenoma detectors, and performance levels were maintained over time. Higher detectors had ADRs of 15% overall (men, 20%; women, 10%) and also detected more adenomas per case (higher/lower detectors, 21.7/10.4 adenomas per :100 examinations).
Conclusions: The differences in ADRs were due to variation in performance of the endoscopists. Long-term follow-up will determine whether this variation is clinically important. We suggest that the standards in higher detecting centers should be achievable by all endoscopists screening unscreened populations aged older than 55 years. Endoscopists should aim to stay above the lower 95% confidence interval band for 200 examinations (10% overall; 5% in women, 15% in men).
Resumo:
One can partially eliminate motor skills acquired through practice in the hours immediately following practice by applying repetitive transcranial stimulation (rTMS) over the primary motor cortex. The disruption of acquired levels of performance has been demonstrated on tasks that are ballistic in nature. The authors investigated whether motor recall on a discrete aiming task is degraded following a disruption of the primary motor cortex induced via rTMS. Participants (N = 16) maintained acquired performance levels and patterns of muscle activity following the application of rTMS. despite a reduction in corticospinal excitability. Disruption of the primary motor cortex during a consolidation period did not influence the retention of acquired skill in this type of discrete visuomotor task.
Resumo:
The initial part of this paper reviews the early challenges (c 1980) in achieving real-time silicon implementations of DSP computations. In particular, it discusses research on application specific architectures, including bit level systolic circuits that led to important advances in achieving the DSP performance levels then required. These were many orders of magnitude greater than those achievable using programmable (including early DSP) processors, and were demonstrated through the design of commercial digital correlator and digital filter chips. As is discussed, an important challenge was the application of these concepts to recursive computations as occur, for example, in Infinite Impulse Response (IIR) filters. An important breakthrough was to show how fine grained pipelining can be used if arithmetic is performed most significant bit (msb) first. This can be achieved using redundant number systems, including carry-save arithmetic. This research and its practical benefits were again demonstrated through a number of novel IIR filter chip designs which at the time, exhibited performance much greater than previous solutions. The architectural insights gained coupled with the regular nature of many DSP and video processing computations also provided the foundation for new methods for the rapid design and synthesis of complex DSP System-on-Chip (SoC), Intellectual Property (IP) cores. This included the creation of a wide portfolio of commercial SoC video compression cores (MPEG2, MPEG4, H.264) for very high performance applications ranging from cell phones to High Definition TV (HDTV). The work provided the foundation for systematic methodologies, tools and design flows including high-level design optimizations based on "algorithmic engineering" and also led to the creation of the Abhainn tool environment for the design of complex heterogeneous DSP platforms comprising processors and multiple FPGAs. The paper concludes with a discussion of the problems faced by designers in developing complex DSP systems using current SoC technology. © 2007 Springer Science+Business Media, LLC.
Resumo:
Introduction
Evaluating quality of palliative day services is essential for assessing care across diverse settings, and for monitoring quality improvement approaches.
Aim
To develop a set of quality indicators for assessment of all aspects (structure, process and outcome) of care in palliative day services.
Methods
Using a modified version of the RAND/UCLA appropriateness method (Fitch et al., 2001), a multidisciplinary panel of 16 experts independently completed a survey rating the appropriateness of 182 potential quality indicators previously identified during a systematic evidence review. Panel members then attended a one day, face-to-face meeting where indicators were discussed and subsequently re-rated. Panel members were also asked to rate the feasibility and necessity of measuring each indicator.
Results
71 indicators classified as inappropriate during the survey were removed based on median appropriateness ratings and level of agreement. Following the panel discussions, a further 60 were removed based on appropriateness and feasibility ratings, level of agreement and assessment of necessity. Themes identified during the panel discussion and findings of the evidence review were used to translate the remaining 51 indicators into a final set of 27.
Conclusion
The final indicator set included information on rationale and supporting evidence, methods of assessment, risk adjustment, and recommended performance levels. Further implementation work will test the suitability of this ‘toolkit’ for measurement and benchmarking. The final indicator set provides the basis for standardised assessment of quality across services, including care delivered in community and primary care settings.
Reference
• Fitch K, Bernstein SJ, Aguilar MD, et al. The RAND/UCLA Appropriateness Method User’s Manual. Santa Monica, CA: RAND Corporation; 2001. http://www.rand.org/pubs/monograph_reports/MR1269
Resumo:
Purpose The aim of this paper is to explore the issues involved in developing and applying performance management approaches within a large UK public sector department using a multiple stakeholder perspective and an accompanying theoretical framework. Design/methodology/approach An initial short questionnaire was used to determine perceptions about the implementation and effectiveness of the new performance management system across the organisation. In total, 700 questionnaires were distributed. Running concurrently with an ethnographic approach, and informed by the questionnaire responses, was a series of semi-structured interviews and focus groups. Findings Staff at all levels had an understanding of the new system and perceived it as being beneficial. However, there were concerns that the approach was not continuously managed throughout the year and was in danger of becoming an annual event, rather than an ongoing process. Furthermore, the change process seemed to have advanced without corresponding changes to appraisal and reward and recognition systems. Thus, the business objectives were not aligned with motivating factors within the organisation. Research limitations/implications Additional research to test the validity and usefulness of the theoretical model, as discussed in this paper, would be beneficial. Practical implications The strategic integration of the stakeholder performance measures and scorecards was found to be essential to producing an overall stakeholder-driven strategy within the case study organisation. Originality/value This paper discusses in detail the approach adopted and the progress made by one large UK public sector organisation, as it attempts to develop better relationships with all of its stakeholders and hence improve its performance. This paper provides a concerted attempt to link theory with practice.
Resumo:
This paper examines the relative efficiency of UK credit unions. Radial and non-radial measures of input cost efficiency plus associated scale efficiency measures are computed for a selection of input output specifications. Both measures highlighted that UK credit unions have considerable scope for efficiency gains. It was mooted that the documented high levels of inefficiency may be indicative of the fact that credit unions, based on clearly defined and non-overlapping common bonds, are not in competition with each other for market share. Credit unions were also highlighted as suffering from a considerable degree of scale inefficiency with the majority of scale inefficient credit unions subject to decreasing returns to scale. The latter aspect highlights that the UK Government's goal of larger credit unions must be accompanied by greater regulatory freedom if inefficiency is to be avoided. One of the advantages of computing non-radial measures is that an insight into potential over- or under-expenditure on specific inputs can be obtained through a comparison of the non-radial measure of efficiency with the associated radial measure. Two interesting findings emerged, the first that UK credit unions over-spend on dividend payments and the second that they under-spend on labour costs.
Resumo:
Sexual selection theory suggests that females might prefer males on the basis of testosterone (T)-dependent secondary sexual traits such as song. Correlational studies have linked high plasma T-levels to high diurnal song output. This has been confirmed in experiments where T-levels were kept high at times when natural T-levels have decreased. However, surprisingly little is known about the relation between T-levels during the early breeding season and song. In many passerine birds males sing at a high rate at dawn early in the breeding season, referred to as the dawn chorus. In blue tits (Parus caeruleus), the dawn chorus coincides with the fertile period of the female, whereas diurnal song occurs throughout the breeding season. Previous studies on blue tits showed that characteristics of the dawn chorus correlate with male reproductive success. We experimentally elevated plasma T-levels in male blue tits during the pre-fertile and fertile period. Our aim was to test whether increased plasma T-levels affect dawn song characteristics and increase the amount of diurnal song. Although T-implants successfully raised circulating T-levels, we did not find any difference between T- and control males in temporal performance measures of dawn song or in diurnal song output. Our results suggest that either there is no direct causal link between song output or quality and individual T-levels, or experimental manipulations of T-levels using implants do not permit detection of such effects during the early breeding season. Although we cannot exclude that individual T-levels are causally linked to other (e.g. structural) song parameters, our results cast doubt on T-dependence as the mechanisms that enforces honesty on song as a sexually selected trait.
Resumo:
Objective: To compare baseline cardiovascular risk management between people recruited from two different healthcare systems, to a research trial of an intervention to optimize secondary prevention. Design: Cross-sectional study. Setting: General practices, randomly selected: 16 in Northern Ireland (NI) (UK NHS, ‘strong’ infrastructure); 32 in Republic of Ireland (RoI) (mixed healthcare economy, less infrastructure). Patients: 903 (mean age 67.5 years; 69.9% male); randomly selected, known coronary heart disease. Main outcome measures: Blood pressure, cholesterol, medications; validated questionnaires for diet (DINE), exercise (Godin), quality of life (SF12); healthcare usage. Results: More RoI than NI participants had systolic BP>140 mmHg (37% v 28%, p=0.01) and cholesterol >5mmol/l (24% v 17%, p=0.02): RoI mean systolic BP was higher (139 v 132 mm Hg). More RoI participants reported a high fibre intake (35% v 23%), higher levels of physical activity (62% v 44%), and better physical and mental health (SF12); they had more GP (5.6 v 4.4) and fewer nurse visits (1.6 v 2.1) in the previous year. Fewer in RoI (55% v 70%) were prescribed B blockers. Both groups’ ACE inhibitor (41%; 48%) prescribing was similar; high proportions were prescribed statins (84%; 85%) and aspirin (83%; 77%). Conclusions Blood pressure and cholesterol are better controlled among patients in a primary healthcare system with a ‘strong’ infrastructure supporting computerization and rewarding measured performance but this is not associated with healthier lifestyle or better quality of life. Further exploration of differences in professionals’ and patients’ engagement in secondary prevention in different healthcare systems is needed.
Resumo:
This paper proposes a decoupled fault ride-through strategy for a doubly fed induction generator (DFIG) to enhance network stability during grid disturbances. The decoupled operation proposes that a DFIG operates as an induction generator (IG) with the converter unit acting as a reactive power source during a fault condition. The transition power characteristics of the DFIG have been analyzed to derive the capability of the proposed strategy under various system conditions. The optimal crowbar resistance is obtained to exploit the maximum power capability from the DFIG during decoupled operation. The methods have been established to ensure proper coordination between the IG mode and reactive power compensation from the grid-side converter during decoupled operation. The viability and benefits of the proposed strategy are demonstrated using different test network structures and different wind penetration levels. Control performance has been benchmarked against existing grid code standards and commercial wind generator systems, based on the optimal network support required (i.e., voltage or frequency) by the system operator from a wind farm installed at a particular location.
Resumo:
Variation of the bypass nozzle exit area enables optimization of the turbofan engine operating cycle over a wider range of operational conditions resulting in improved thrust and/or fuel consumption. Two mechanisms for varying the nozzle area have been investigated. The first uses an array of chevrons which when closed, form a full body of revolution and when warped/curved, increase the exit area while forming a serrated trailing edge. The second technique incorporates an axially translating section of the nacelle shroud and uses the change in the nozzle boat-tail radial location with the axial location as a means to vary the nozzle exit area. To analyse the effects on a typical rotor/stator stage, computational fluid dynamics simulations of the NASA Rotor 67, Stator 67A stage integrated into a custom-built nacelle were performed. Nozzles with 8, 12, and 16 chevrons were simulated to evaluate the impact of the variation in geometry upon the nacelle wake and local forces. Gross thrust of the nacelle and the turbulent kinetic energy (TKE) variation through the wake is compared. The chevron nozzle attains a nearly 2 per cent maximum thrust improvement over the translating nozzle technique. The chevron nozzle also has significantly lower (nearly 8 per cent) peak TKE levels in the jet plume.