15 resultados para Mass Measurement
Resumo:
A new approach to the search for residues of unknown growth promoting agents such as anabolic steroids and -agonists in feed is presented. Following primary extraction and clean-up, samples are separated using gradient liquid chromatography (LC). The effluent is split towards two identical 96-well fraction collectors and an optional electrospray quadrupole time-of-flight mass spectrometry (QTOFMS) system for accurate mass measurement. One 96-well plate is used for a bioassay (enzyme-immuno assay, receptor assay) and will detect the bioactivity and position of the relevant peak in the chromatogram. The positive well in the second 96-well plate is used for identification by LC/QTOFMS/MS. The value of this LC/bioassay/QTOFMS/MS methodology is highlighted by the finding and structure elucidation of a new -agonist in a feed extract.
Resumo:
Background: Underweight and severe and morbid obesity are associated with highly elevated risks of adverse health outcomes. We estimated trends in mean body-mass index (BMI), which characterises its population distribution, and in the prevalences of a complete set of BMI categories for adults in all countries.
Methods: We analysed, with use of a consistent protocol, population-based studies that had measured height and weight in adults aged 18 years and older. We applied a Bayesian hierarchical model to these data to estimate trends from 1975 to 2014 in mean BMI and in the prevalences of BMI categories (<18·5 kg/m2 [underweight], 18·5 kg/m2 to <20 kg/m2, 20 kg/m2 to <25 kg/m2, 25 kg/m2 to <30 kg/m2, 30 kg/m2 to <35 kg/m2, 35 kg/m2 to <40 kg/m2, ≥40 kg/m2 [morbid obesity]), by sex in 200 countries and territories, organised in 21 regions. We calculated the posterior probability of meeting the target of halting by 2025 the rise in obesity at its 2010 levels, if post-2000 trends continue.
Findings: We used 1698 population-based data sources, with more than 19·2 million adult participants (9·9 million men and 9·3 million women) in 186 of 200 countries for which estimates were made. Global age-standardised mean BMI increased from 21·7 kg/m2 (95% credible interval 21·3–22·1) in 1975 to 24·2 kg/m2 (24·0–24·4) in 2014 in men, and from 22·1 kg/m2 (21·7–22·5) in 1975 to 24·4 kg/m2 (24·2–24·6) in 2014 in women. Regional mean BMIs in 2014 for men ranged from 21·4 kg/m2 in central Africa and south Asia to 29·2 kg/m2 (28·6–29·8) in Polynesia and Micronesia; for women the range was from 21·8 kg/m2 (21·4–22·3) in south Asia to 32·2 kg/m2 (31·5–32·8) in Polynesia and Micronesia. Over these four decades, age-standardised global prevalence of underweight decreased from 13·8% (10·5–17·4) to 8·8% (7·4–10·3) in men and from 14·6% (11·6–17·9) to 9·7% (8·3–11·1) in women. South Asia had the highest prevalence of underweight in 2014, 23·4% (17·8–29·2) in men and 24·0% (18·9–29·3) in women. Age-standardised prevalence of obesity increased from 3·2% (2·4–4·1) in 1975 to 10·8% (9·7–12·0) in 2014 in men, and from 6·4% (5·1–7·8) to 14·9% (13·6–16·1) in women. 2·3% (2·0–2·7) of the world's men and 5·0% (4·4–5·6) of women were severely obese (ie, have BMI ≥35 kg/m2). Globally, prevalence of morbid obesity was 0·64% (0·46–0·86) in men and 1·6% (1·3–1·9) in women.
Interpretation: If post-2000 trends continue, the probability of meeting the global obesity target is virtually zero. Rather, if these trends continue, by 2025, global obesity prevalence will reach 18% in men and surpass 21% in women; severe obesity will surpass 6% in men and 9% in women. Nonetheless, underweight remains prevalent in the world's poorest regions, especially in south Asia.
Resumo:
Context: The masses previously obtained for the X-ray binary 2S 0921-630 inferred a compact object that was either a high-mass neutron star or low-mass black-hole, but used a previously published value for the rotational broadening (v sin i) with large uncertainties. Aims: We aim to determine an accurate mass for the compact object through an improved measurement of the secondary star's projected equatorial rotational velocity. Methods: We have used UVES echelle spectroscopy to determine the v sin i of the secondary star (V395 Car) in the low-mass X-ray binary 2S 0921-630 by comparison to an artificially broadened spectral-type template star. In addition, we have also measured v sin i from a single high signal-to-noise ratio absorption line profile calculated using the method of Least-Squares Deconvolution (LSD). Results: We determine v sin i to lie between 31.3±0.5 km s-1 to 34.7±0.5 km s-1 (assuming zero and continuum limb darkening, respectively) in disagreement with previous results based on intermediate resolution spectroscopy obtained with the 3.6 m NTT. Using our revised v sin i value in combination with the secondary star's radial velocity gives a binary mass ratio of 0.281±0.034. Furthermore, assuming a binary inclination angle of 75° gives a compact object mass of 1.37±0.13 M_?. Conclusions: We find that using relatively low-resolution spectroscopy can result in systemic uncertainties in the measured v sin i values obtained using standard methods. We suggest the use of LSD as a secondary, reliable check of the results as LSD allows one to directly discern the shape of the absorption line profile. In the light of the new v sin i measurement, we have revised down the compact object's mass, such that it is now compatible with a canonical neutron star mass.
Resumo:
To increase eco-efficiency environmental information needs to be integrated into corporate decision making. For decision makers the interpretation of eco-efficiency as a ratio can however be quite difficult in practice. One of the reasons for this is, that eco-efficiency as a ratio is measured in a unit, that is difficult to interpret. This article therefore suggests an alternative measure for eco-efficiency. The Environmental Value Added, the measure proposed in this paper, reflects the excess economic benefit, resulting from the difference between the eco-efficiency under consideration and a benchmark eco-efficiency. It is measured in a purely monetary unit and is thus easier to interpret and integrate than eco-efficiency as a ratio.
Resumo:
The radiation efficiency and resonance frequency of five compact antennas worn by nine individual test subjects was measured at 2.45 GHz in a reverberation chamber. The results show that, despite significant differences in body mass, wearable antenna radiation efficiency had a standard deviation less than 0.6 dB and the resonance frequency shift was less than 1% between test subjects. Variability in the radiation efficiency and resonance frequency shift between antennas was largely dependant on body tissue coupling which is related to both antenna geometry and radiation characteristics. The reverberation chamber measurements were validated using a synthetic tissue phantom and compared with results obtained in a spherical near field chamber and finite-difference time-domain (FDTD) simulation.
Resumo:
Measurement of steroid esters in bovine hair samples, using sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS), provides a powerful tool for identifying animals treated illicitly with growth promoters. The successful application of such testing requires appropriate sampling of hair from treated animals. This paper describes the results of hair analysis by LC-MS/MS for two animal studies in which animals were treated with estradiol-3-benzoate and nortestosterone decanoate. The results from the first animal study indicate that animals treated with these anabolic steroids may not always be identified from analysis of hair samples; positive test results occur sporadically and only for some of the treated animals. The results from the second animal study identify conditions attaching to positive hair samples, such as, that concentrations of steroid esters in hair are related to distance of sampling from point of injection and to time post-treatment, that concentrations of steroid esters in hair are related to dose given to the animal but that this relationship may vary over time post-treatment, and that steroid esters may be measured in regrowth hair taken some weeks after treatment. Steroid esters are determined along the length of the hair, confirming that accumulation of steroid esters into hair occurs from various sources, including blood, sweat and sebum. The reported research provides some useful insights into the mechanisms governing the persistence of steroid esters in bovine hair following illicit treatment with growth promoters. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Many different immunochemical platforms exist for the screening of naturally occurring contaminants in food from the low cost enzyme linked immunosorbent assays (ELISA) to the expensive instruments such as optical biosensors based on the phenomenon of surface plasmon resonance (SPR). The primary aim of this study was to evaluate and compare a number of these platforms to assess their accuracy and precision when applied to naturally contaminated samples containing HT-2/T-2 mycotoxins. Other important factors considered were the speed of analysis, ease of use (sample preparation techniques and use of the equipment) and ultimately the cost implications. The three screening procedures compared included an SPR biosensor assay, a commercially available ELISA and an enzyme-linked immunomagnetic electrochemical array (ELIME array). The qualitative data for all methods demonstrated very good overall agreements with each other, however on comparison with mass spectrometry confirmatory results, the ELISA and SPR assay performed slightly better than the ELIME array, exhibiting an overall agreement of 95.8% compared to 91.7%. Currently, SPR is more costly than the other two platforms and can only be used in the laboratory whereas in theory both the ELISA and ELIME array are portable and can be used in the field, but ultimately this is dependent on the sample preparation techniques employed. Sample preparative techniques varied for all methods evaluated, the ELISA was the most simple to perform followed by that of the SPR method. The ELIME array involved an additional clean-up step thereby increasing both the time and cost of analysis. Therefore in the current format, field use would not be an option for the ELIME array. In relation to speed of analysis, the ELISA outperformed the other methods.
Resumo:
A simple, new method permitting the simultaneous determination and confirmation of trace residues of 24 different growth promoters and metabolites using liquid chromatography-mass spectrometry was developed and validated. The compounds were extracted from bovine tissue using acetonitrile; sodium sulphate was also added at this stage to aid with purification. The resulting mixture was then evaporated to approximately 1 ml and subsequently centrifuged at high speed and an aliquot injected onto the LC-MS/MS system. The calculated CC values ranged between 0.11 and 0.46 mu g kg-1; calculated CC were in the range 0.19-0.79 mu g kg-1. Accuracy, measurement of uncertainty, repeatability and linearity were also determined for each analyte. The analytical method was applied to a number of bovine tissue samples imported into Ireland from third countries. Levels of progesterone were found in a number of samples at concentrations ranging between 0.28 and 30.30 mu g kg-1. Levels of alpha- and beta-testosterone were also found in a number of samples at concentrations ranging between 0.22 and 8.63 mu g kg-1 and between 0.16 and 2.08 mu g kg-1 respectively.
Resumo:
A confirmatory method has been developed and validated that allows for the simultaneous detection of medroxyprogesterone acetate (MPA), megestrol acetate (MGA), melengestrol acetate (MLA), chlormadinone acetate (CMA) and delmadinone acetate (DMA) in animal kidney fat using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The compounds were extracted from kidney fat using acetonitrile, defatted using a hexane wash and subsequent saponification. Extracts were then purified on Isolute CN solid-phase extraction cartridges and analysed by LC-MS/MS. The method was validated in animal kidney fat in accordance with the criteria defined in Commission Decision 2002/657/EC. The decision limit (CC) was calculated to be 0.12, 0.48, 0.40, 0.63 and 0.54 g kg-1, respectively, for MPA, MGA, MLA, DMA and CMA, with respective detection capability (CC) values of 0.20, 0.81, 0.68, 1.07 and 0.92 g kg-1. The measurement uncertainty of the method was estimated at 16, 16, 19, 27 and 26% for MPA, MGA, MLA, DMA and CMA, respectively. Fortifying kidney fat samples (n = 18) in three separate assays showed the accuracy of the method to be between 98 and 100%. The precision of the method, expressed as % RSD, for within-laboratory reproducibility at three levels of fortification (1, 1.5 and 2 g kg-1 for MPA, 5, 7.5 and 10 g kg-1 for MGA, MLA, DMA and CMA) was less than 5% for all analytes.
Resumo:
Dielectronic recombination was investigated for He+, the simplest ion for which this process is possible. This work was done using the light-ion storage ring and electron cooler at the Indiana University Cyclotron Facility. Resonant recombination yields resulting from 1s +e- --> nln'l' transitions were observed with sufficient resolution (about 1 eV in the center of mass) to isolate and obtain cross sections for the 2s 2p 3P0 and 2p2 1D terms. The measured cross sections, integrated over the DELTAn = 1 2ln'l' states, agree in magnitude with theoretical calculations. Additionally, DELTAn = 2 dielectronic recombination events associated with 3ln'l' intermediate states were observed.
Resumo:
The weakest step in the analytical procedure for speciation analysis is extraction from a biological material into an aqueous solution which undergoes HPLC separation and then simultaneous online detection by elemental and molecular mass spectrometry (ICP-MS/ES-MS). This paper describes a study to determine the speciation of arsenic and, in particular, the arsenite phytochelatin complexes in the root from an ornamental garden plant Thunbergia alata exposed to 1 mg As L(-1) as arsenate. The approach of formic acid extraction followed by HPLC-ES-MS/ICP-MS identified different As(III)-PC complexes in the extract of this plant and made their quantification via sulfur (m/z 32) and arsenic (m/z 75) possible. Although sulfur sensitivity could be significantly increased when xenon was used as collision gas in ICP-qMS, or when HR-ICP-MS was used in medium resolution, the As:S ratio gave misleading results in the identification of As(III)-PC complexes due to the relatively low resolution of the chromatography system in relation to the variety of As-peptides in plants. Hence only the parallel use of ES-MS/ICP-MS was able to prove the occurrence of such arsenite phytochelatin complexes. Between 55 and 64% of the arsenic was bound to the sulfur of peptides mainly as As(III)(PC(2))(2), As(III)(PC(3)) and As(III)(PC(4)). XANES (X-ray absorption near-edge spectroscopy) measurement, using the freshly exposed plant root directly, confirmed that most of the arsenic is trivalent and binds to S of peptides (53% As-S) while 38% occurred as arsenite and only 9% unchanged as arsenate. EXAFS data confirmed that As-S and As-O bonds occur in the plants. This study confirms, for the first time, that As-peptides can be extracted by formic acid and chromatographically separated on a reversed-phase column without significant decomposition or de-novo synthesis during the extraction step.
Resumo:
Obesity has been linked with elevated levels of C-reactive protein (CRP), and both have been associated with increased risk of mortality and cardiovascular disease (CVD). Previous studies have used a single ‘baseline’ measurement and such analyses cannot account for possible changes in these which may lead to a biased estimation of risk. Using four cohorts from CHANCES which had repeated measures in participants 50 years and older, multivariate time-dependent Cox proportional hazards was used to estimate hazard ratios (HR) and 95 % confidence intervals (CI) to examine the relationship between body mass index (BMI) and CRP with all-cause mortality and CVD. Being overweight (≥25–<30 kg/m2) or moderately obese (≥30–<35) tended to be associated with a lower risk of mortality compared to normal (≥18.5–<25): ESTHER, HR (95 % CI) 0.69 (0.58–0.82) and 0.78 (0.63–0.97); Rotterdam, 0.86 (0.79–0.94) and 0.80 (0.72–0.89). A similar relationship was found, but only for overweight in Glostrup, HR (95 % CI) 0.88 (0.76–1.02); and moderately obese in Tromsø, HR (95 % CI) 0.79 (0.62–1.01). Associations were not evident between repeated measures of BMI and CVD. Conversely, increasing CRP concentrations, measured on more than one occasion, were associated with an increasing risk of mortality and CVD. Being overweight or moderately obese is associated with a lower risk of mortality, while CRP, independent of BMI, is positively associated with mortality and CVD risk. If inflammation links CRP and BMI, they may participate in distinct/independent pathways. Accounting for independent changes in risk factors over time may be crucial for unveiling their effects on mortality and disease morbidity.
Resumo:
The ejected mass distribution of Type Ia supernovae (SNe Ia) directly probes progenitor evolutionary history and explosion mechanisms, with implications for their use as cosmological probes. Although the Chandrasekhar mass is a natural mass scale for the explosion of white dwarfs as SNe Ia, models allowing SNe Ia to explode at other masses have attracted much recent attention. Using an empirical relation between the ejected mass and the light-curve width, we derive ejected masses Mej and 56Ni masses MNi for a sample of 337 SNe Ia with redshifts z <0.7 used in recent cosmological analyses. We use hierarchical Bayesian inference to reconstruct the joint Mej-MNi distribution, accounting for measurement errors. The inferred marginal distribution of Mej has a long tail towards sub-Chandrasekhar masses, but cuts off sharply above 1.4 M⊙. Our results imply that 25-50 per cent of normal SNe Ia are inconsistent with Chandrasekhar-mass explosions, with almost all of these being sub-Chandrasekhar mass; super-Chandrasekhar-mass explosions make up no more than 1 per cent of all spectroscopically normal SNe Ia. We interpret the SN Ia width-luminosity relation as an underlying relation between Mej and MNi, and show that the inferred relation is not naturally explained by the predictions of any single known explosion mechanism.
Resumo:
With the main focus on safety, design of structures for vibration serviceability is often overlooked or mismanaged, resulting in some high profile structures failing publicly to perform adequately under human dynamic loading due to walking, running or jumping. A standard tool to inform better design, prove fitness for purpose before entering service and design retrofits is modal testing, a procedure that typically involves acceleration measurements using an array of wired sensors and force generation using a mechanical shaker. A critical but often overlooked aspect is using input (force) to output (response) relationships to enable estimation of modal mass, which is a key parameter directly controlling vibration levels in service.
This paper describes the use of wireless inertial measurement units (IMUs), designed for biomechanics motion capture applications, for the modal testing of a 109 m footbridge. IMUs were first used for an output-only vibration survey to identify mode frequencies, shapes and damping ratios, then for simultaneous measurement of body accelerations of a human subject jumping to excite specific vibrations modes and build up bridge deck accelerations at the jumping location. Using the mode shapes and the vertical acceleration data from a suitable body landmark scaled by body mass, thus providing jumping force data, it was possible to create frequency response functions and estimate modal masses.
The modal mass estimates for this bridge were checked against estimates obtained using an instrumented hammer and known mass distributions, showing consistency among the experimental estimates. Finally, the method was used in an applied research application on a short span footbridge where the benefits of logistical and operational simplicity afforded by the highly portable and easy to use IMUs proved extremely useful for an efficient evaluation of vibration serviceability, including estimation of modal masses.