133 resultados para METABOLITES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A chiral gas chromatographic assay has been developed for quantitative analysis of ethosuximide and its major metabolites in rat urine. The extraction procedure was found to be precise and reproducible. Recovery was in the range of 94-98%, intraday CV(%) was 0.92% for (S)-ethosuximide (50 mug/ml) and 0.51% for (R)-ethosuximide (50 mug/ml). Interday CV(%) was 1.12% for (S)-ethosuximide and 0.72% for (R)-ethosuximide. The limit of detection was determined to be around 0.01 mug/ml for each enantiomer. Following administration of rac-ethosuximide by i.v., i.p. and oral routes, unchanged ethosuximide was detected in urine up to 72h after drug administration. The appearance of all detected metabolites occurred Within 24h of drug administration. Significantly more (S)-ethosuximide was excreted unchanged than (R)-ethosuximide with all three routes studied. A substantial amount of the drug was eliminated as the 2-(1-hydroxyethyl)-2-methylsuccinimide (2 pairs of diastereoisomers). Much less drug was eliminated as the 2-ethyl-3-hydroxy-2-methylsuccinimide with only one diastereoisomer observed. Examination of the one pair of diastereoisomers of 2-(1-hydroxyethyl)-2-methylsuccinimide that was resolved showed preferential excretion of one isomer. Comparison of both pairs of diastereoisomers showed that one pair was formed in preference to the other with a ratio of approximately 0.8:1. It is concluded that stereoselective metabolism of ethosuximide occurs. Copyright (C) 2001 John Wiley & Sons, Ltd. Author Keywords: chiral pharmacokinetics; ethosuximide enantiomers; metabolism; rat; urinary excretion; gas chromatography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract An HPLC method has been developed and validated for the determination of spironolactone, 7a-thiomethylspirolactone and canrenone in paediatric plasma samples. The method utilises 200 µl of plasma and sample preparation involves protein precipitation followed by Solid Phase Extraction (SPE). Determination of standard curves of peak height ratio (PHR) against concentration was performed by weighted least squares linear regression using a weighting factor of 1/concentration2. The developed method was found to be linear over concentration ranges of 30–1000 ng/ml for spironolactone and 25–1000 ng/ml for 7a-thiomethylspirolactone and canrenone. The lower limit of quantification for spironolactone, 7a-thiomethylspirolactone and canrenone were calculated as 28, 20 and 25 ng/ml, respectively. The method was shown to be applicable to the determination of spironolactone, 7a-thiomethylspirolactone and canrenone in paediatric plasma samples and also plasma from healthy human volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NMR studies were conducted with the aim of determining the diastereoisomeric ratio of a commercially supplied sample of mesoridazine (MES) and to compare the results with a freshly synthesised sample of MES. The results indicated that the commercially supplied MES consisted almost entirely of one diastereoisomeric pair, which was in agreement with previous findings reported by Eap et al. (J Chromatogr 669:271-279, 1995). The synthesised sample of MES was analysed by NMR in two stages: 1) as the initial product isolated as the free base from the direct synthesis, and 2) as the free base isolated from the crystallised besylate salt of the synthetic product. The NMR results show that the initial synthetic product consisted of two equal pairs of diastereoisomers. The diastereoisomeric pairs were further separated by the addition of the chiral shift reagent (R)-(-)-N-(3,5 dinitrobenzoyl)-alpha-benzylamine to reveal equal quantities of all four enantiomers, clearly observed at the methyl sulfoxide proton peak of the NMR scan. The sample obtained from the crystallisation of MES besylate, however, indicated a significant difference, with a diastereoisomeric ratio of 75:25. The results suggest that MES besylate undergoes preferential crystallisation of one pair of diastereoisomers, with the other pair remaining in solution. (C) 2004 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose-dependent insulinotrophic polypepticle (GIP) and glucagon-like peptide-1 (GLP-1) are important enteroendocrine hormones that are rapidly degraded by an ubiquitous enzyme dipeptidyl peptidase IV to yield truncated metabolites GIP(3-42) and GLP-1 (9-36)amide. In this study, we investigated the effects of sub-chronic exposure to these major circulating forms of GIP and GLP-1 on blood glucose control and endocrine pancreatic function in obese diabetic (ob/ob) mice. A once daily injection of either peptide for 14 days had no effect on body weight, food intake or pancreatic insulin content or islet morphology. GLP-1(9-36)amide also had no effect on plasma glucose homeostasis or insulin secretion. Mice receiving GIP(3-42) exhibited small but significant improvements in non-fasting plasma glucose, glucose tolerance and glycaemic response to feeding. Accordingly, plasma insulin responses were unchanged suggesting that the observed enhancement of insulin sensitivity was responsible for the improvement in glycaemic control. These data indicate that sub-chronic exposure to GIP and GLP-1 metabolites does not result in physiological impairment of insulin secretion or blood glucose control. GIP(3-42) might exert an overall beneficial effect by improving insulin sensitivity through extrapancreatic action.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Absolute configurations of a number of cis-dihydrodiols (cis-1,2-dihydroxy-3,5-cyclohexadienes), synthetically useful products of TDO-catalyzed dihydroxylations of 1,2- and 1,3-disubstituted benzene derivatives, have been determined by a comparison of calculated and experimental CD spectra and optical rotations and by methods involving X-ray crystallography, H-1 NMR spectra of diastereoisomeric derivatives, and by stereochemical correlations. The computations disclosed a significant effect of the substituents on conformational equilibria of cis-dihydrodiols and chiroptical properties of individual conformers. The assigned absolute configurations of cis-dihydrodiols have allowed the validity of a simple predictive model for TDO-catalyzed arene dihydroxylations to be extended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of ten cis-dihydro-diol metabolites has been obtained by bacterial biotransformation of the corresponding 1,4-disubstituted benzene substrates using Pseudomonas putida UV4, a source of toluene dioxygenase (TDO). Their enantiomeric excess (ee) values have been established using chiral stationary phase HPLC and H-1 NMR spectroscopy. Absolute configurations of the majority of cis-dihydrodiols have been established using stereochemical correlation and X-ray crystallography and the remainder have been tentatively assigned using NMR spectroscopic methods but finally confirmed by circular dichroism (CD) spectroscopy. These configurational assignments support and extend the validity of an empirical model, previously used to predict the preferred stereochemistry of TDO-catalysed cis-dihydroxylation of ten 1,4-disubstituted benzene substrates, to more than twenty-five examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have determined the absolute configurations of conformationally flexible cis-dihydrodiol metabolites (cis-1,2-dihydroxy-3,5-cyclohexadienes), bearing different substituents (e.g., Br, F, CF3, CN, Me) in 3- and 5-positions, by the method of confrontation of experimental and calculated electronic CD spectra and optical rotations. Convergent results were obtained by both methods in eight out of ten cases. For the difficult cases, where either conformer population and/or chiroptical properties (calculated rotational strengths of the long-wavelength Cotton effect or optical rotations) of contributing conformers remain inconclusive, the absolute configuration could still be correctly assigned based on one of the biased properties (either ECD or optical rotation). This approach appears well-suited for a broad spectrum of conformationally flexible chiral molecules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC method has been developed and validated for the rapid determination of mercaptopurine and four of its metabolites; thioguanine, thiouric acid, thioxanthine and methylmercaptopurine in plasma and red blood cells. The method involves a simple treatment procedure based on deproteinisation by perchloric acid followed by acid hydrolysis and heating for 45 min at 100 degrees C. The developed method was linear over the concentration range studied with a correlation coefficient >0.994 for all compounds in both plasma and erythrocytes. The lower limits of quantification were 13, 14, 3, 2, 95 pmol/8 x 101 RBCs and 2, 5, 2, 3, 20 ng/ml plasma for thioguanine, thiouric acid, mercaptopurine, thioxanthine and methylmercaptopurine, respectively. The method described is selective and sensitive enough to analyse the different metabolites in a single run under isocratic conditions. Furthermore, it has been shown to be applicable for monitoring these metabolites in paediatric patients due to the low volume requirement (200 mu l of plasma or erythrocytes) and has been successfully applied for investigating population pharmacokinetics, pharmacogenetics and non-adherence to therapy in these patients. (C) 2008 Elsevier B.V. All rights reserved.