10 resultados para Intellectual evaluation - WISC III


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A generic architecture for implementing the advanced encryption standard (AES) encryption algorithm in silicon is proposed. This allows the instantiation of a wide range of chip specifications, with these taking the form of semiconductor intellectual property (IP) cores. Cores implemented from this architecture can perform both encryption and decryption and support four modes of operation: (i) electronic codebook mode; (ii) output feedback mode; (iii) cipher block chaining mode; and (iv) ciphertext feedback mode. Chip designs can also be generated to cover all three AES key lengths, namely 128 bits, 192 bits and 256 bits. On-the-fly generation of the round keys required during decryption is also possible. The general, flexible and multi-functional nature of the approach described contrasts with previous designs which, to date, have been focused on specific implementations. The presented ideas are demonstrated by implementation in FPGA technology. However, the architecture and IP cores derived from this are easily migratable to other silicon technologies including ASIC and PLD and are capable of covering a wide range of modem communication systems cryptographic requirements. Moreover, the designs produced have a gate count and throughput comparable with or better than the previous one-off solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synthesis and photophysical evaluation of a new supramolecular lanthanide complex is described which was developed as a luminescent contrast agent for bone structure analysis. We show that the Eu(III) emission of this complex is not pH dependent within the physiological pH range, and that its steady state emission is not significantly modulated by a series of group I and II as well as d-metal ions, and that this agent can be successfully employed to image mechanically formed cracks (scratches) in bone samples after 4 or 24 hours, using confocal laser-scanning microscopy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim This study aimed to develop and evaluate a multi-media educational resource in palliative and end-of-life care for specialist palliative care and intellectual disability services which promoted collaborative working. Methods: A mixed methods design involving three phases was used. Qualitative data were obtained from semi-structured interviews with a purposive sample of professionals (n=30) and family carers (n=5) and from two focus groups with people with intellectual disabilities (n=17). Data were content analysed as outlined y Newell and Burnard (2006). This identified training needs and issues, in end-of-life care for this population which were confirmed through quantitative data from services in a regional scoping study analysed using descriptive statistics. A DVD and manual were developed and evaluated with twelve professionals. Data were collected using a solicited diary, the Readiness for Inter-professional Learning Scale, Likert Scales and an evaluation questionnaire. Thematic analysis and descriptive statistics appropriate to data were used.Results: Findings suggest that this resource demonstrates the need for and benefits of partnership working and transferability of this learning to practice could address issues at end-of-life for people with intellectual disabilities. Conclusions: Findings of this study have importance for partnership working and service provision in end-of-life care for this population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tephras are important for the NZ-INTIMATE project because they link all three records comprising the composite inter-regional stratotype developed for the New Zealand climate event stratigraphy (NZ-CES). Here we firstly report new calendar ages for 24 widespread marker tephras erupted since 30,000 calendar (cal.) years ago in New Zealand to help facilitate their use as chronostratigraphic dating tools for the NZ-CES and for other palaeoenvironmental and geological applications. The selected tephras comprise 12 rhyolitic tephras from Taupo, nine rhyolitic tephras from Okataina, one peralkaline rhyolitic tephra from Tuhua, and one andesitic tephra each from Tongariro and Egmont/Taranaki volcanic centres. Age models for the tephras were obtained using three methods: (i) C-based wiggle-match dating of wood from trees killed by volcanic eruptions (these dates published previously); (ii) flexible depositional modelling of a high-resolution C-dated age-depth sequence at Kaipo bog using two Bayesian-based modelling programs, Bacon and OxCal's P_Sequence function, and the IntCal09 data set (with SH offset correction-44±17yr); and (iii) calibration of C ages using OxCal's Tau_Boundary function and the SHCal04 and IntCal09 data sets. Our preferred dates or calibrated ages for the 24 tephras are as follows (youngest to oldest, all mid-point or mean ages of 95% probability ranges): Kaharoa AD 1314±12; Taupo (Unit Y) AD 232±10; Mapara (Unit X) 2059±118cal.yrBP; Whakaipo (Unit V) 2800±60cal.yrBP; Waimihia (Unit S) 3401±108cal.yrBP; Stent (Unit Q) 4322±112cal.yrBP; Unit K 5111±210cal.yrBP; Whakatane 5526±145cal.yrBP; Tuhua 6577±547cal.yrBP; Mamaku 7940±257cal.yrBP; Rotoma 9423±120cal.yrBP; Opepe (Unit E) 9991±160cal.yrBP; Poronui (Unit C) 11,170±115cal.yrBP; Karapiti (Unit B) 11,460±172cal.yrBP; Okupata 11,767±192cal.yrBP; Konini (bed b) 11,880±183cal.yrBP; Waiohau 14,009±155cal.yrBP; Rotorua 15,635±412cal.yrBP; Rerewhakaaitu 17,496±462cal.yrBP; Okareka 21,858±290cal.yrBP; Te Rere 25,171±964cal.yrBP; Kawakawa/Oruanui 25,358±162cal.yrBP; Poihipi 28,446±670cal.yrBP; and Okaia 28,621±1428cal.yrBP.Secondly, we have re-dated the start and end of the Lateglacial cool episode (climate event NZce-3 in theNZ-CES), previously referred to as the Lateglacial climate reversal, as defined at Kaipo bog in eastern North Island, New Zealand, using both Bacon and OxCal P_Sequence modelling with the IntCal09 data set. The ca1200-yr-long cool episode, indicated by a lithostratigraphic change in the Kaipo peat sequence to grey mudwith lowered carbon content, and a high-resolution pollen-derived cooling signal, began 13,739±125cal.yrBP and ended 12,550±140cal.yrBP (mid-point ages of the 95% highest posterior density regions, Bacon modelling). The OxCal modelling, generating almost identical ages, confirmed these ages. The Lateglacial cool episode (ca 13.8-12.6cal.kaBP) thus overlaps a large part of the entire Antarctic Cold Reversal chronozone (ca 14.1-12.4cal.kaBP or ca 14.6-12.8cal.kaBP), and an early part of the Greenland Stadial-1 (Younger Dryas) chronozone (ca 12.9-11.7cal.kaBP). The timing of the Lateglacial cool episode at Kaipo is broadly consistent with the latitudinal patterns in the Antarctic Cold Reversal signal suggested for the New Zealand archipelago from marine and terrestrial records, and with records from southern South America. © 2012 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Following progress of the dapivirine (DPV)-releasing silicone elastomer (SE) vaginal ring (VR) into Phase III clinical studies, there is now interest in developing next-generation rings that additionally provide contraception. Levonorgestrel (LNG) is a safe and effective progestin that is being widely considered for use as a hormonal contraceptive agent in future multipurpose prevention technology (MPT) products. Although LNG has previously been incorporated into various controlled release SE devices, minimal attention has focused on its propensity to irreversibly react with addition cure SE systems. Here, for the first time, we investigate this LNG binding phenomenon and outline strategies for overcoming it.
Methods: VRs containing various loadings of DPV and LNG were manufactured and in vitro release assessed. Different LNG-only SE samples were also prepared to assess the following parameters: (i) addition cure vs. condensation cure SEs; (ii) different types of addition cure SEs; (iii) mixing time, (iv) cure temperature, (v) cure time; and (vi) LNG particle size. After manufacture, the LNG-only samples were assayed for total drug content using a solvent extraction method. The SE curing reaction and the LNG binding reaction was probed using nuclear magnetic resonance (NMR) spectroscopy. Results:
Under certain drug/formulation/processing conditions, LNG was not recoverable from VRs. Further studies using non-ring samples showed that: (a) the phenomenon was only observed with addition cure SEs (and not condensation cure SEs); (b) the extent of binding was dependent upon the type of addition cure SE; (c) micronised LNG showed significantly greater binding than non-micronised LNG; (d) the extent of binding correlated with increased mixing time, cure time and cure temperature.
Conclusions: Careful control of the API characteristics, the SE composition, and the manufacturing conditions will be necessary to establish a practical VR formulation for controlled release of LNG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Age-related macular degeneration is the most common cause of sight impairment in the UK. In neovascular age-related macular degeneration (nAMD), vision worsens rapidly (over weeks) due to abnormal blood vessels developing that leak fluid and blood at the macula.

OBJECTIVES: To determine the optimal role of optical coherence tomography (OCT) in diagnosing people newly presenting with suspected nAMD and monitoring those previously diagnosed with the disease.

DATA SOURCES: Databases searched: MEDLINE (1946 to March 2013), MEDLINE In-Process & Other Non-Indexed Citations (March 2013), EMBASE (1988 to March 2013), Biosciences Information Service (1995 to March 2013), Science Citation Index (1995 to March 2013), The Cochrane Library (Issue 2 2013), Database of Abstracts of Reviews of Effects (inception to March 2013), Medion (inception to March 2013), Health Technology Assessment database (inception to March 2013).

REVIEW METHODS: Types of studies: direct/indirect studies reporting diagnostic outcomes.

INDEX TEST: time domain optical coherence tomography (TD-OCT) or spectral domain optical coherence tomography (SD-OCT).

COMPARATORS: clinical evaluation, visual acuity, Amsler grid, colour fundus photographs, infrared reflectance, red-free images/blue reflectance, fundus autofluorescence imaging, indocyanine green angiography, preferential hyperacuity perimetry, microperimetry. Reference standard: fundus fluorescein angiography (FFA). Risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. A Markov model was developed (65-year-old cohort, nAMD prevalence 70%), with nine strategies for diagnosis and/or monitoring, and cost-utility analysis conducted. NHS and Personal Social Services perspective was adopted. Costs (2011/12 prices) and quality-adjusted life-years (QALYs) were discounted (3.5%). Deterministic and probabilistic sensitivity analyses were performed.

RESULTS: In pooled estimates of diagnostic studies (all TD-OCT), sensitivity and specificity [95% confidence interval (CI)] was 88% (46% to 98%) and 78% (64% to 88%) respectively. For monitoring, the pooled sensitivity and specificity (95% CI) was 85% (72% to 93%) and 48% (30% to 67%) respectively. The FFA for diagnosis and nurse-technician-led monitoring strategy had the lowest cost (£39,769; QALYs 10.473) and dominated all others except FFA for diagnosis and ophthalmologist-led monitoring (£44,649; QALYs 10.575; incremental cost-effectiveness ratio £47,768). The least costly strategy had a 46.4% probability of being cost-effective at £30,000 willingness-to-pay threshold.

LIMITATIONS: Very few studies provided sufficient information for inclusion in meta-analyses. Only a few studies reported other tests; for some tests no studies were identified. The modelling was hampered by a lack of data on the diagnostic accuracy of strategies involving several tests.

CONCLUSIONS: Based on a small body of evidence of variable quality, OCT had high sensitivity and moderate specificity for diagnosis, and relatively high sensitivity but low specificity for monitoring. Strategies involving OCT alone for diagnosis and/or monitoring were unlikely to be cost-effective. Further research is required on (i) the performance of SD-OCT compared with FFA, especially for monitoring but also for diagnosis; (ii) the performance of strategies involving combinations/sequences of tests, for diagnosis and monitoring; (iii) the likelihood of active and inactive nAMD becoming inactive or active respectively; and (iv) assessment of treatment-associated utility weights (e.g. decrements), through a preference-based study.

STUDY REGISTRATION: This study is registered as PROSPERO CRD42012001930.

FUNDING: The National Institute for Health Research Health Technology Assessment programme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: People with intellectual disabilities often present with unique challenges that make it more difficult to meet their
palliative care needs.
Aim: To define consensus norms for palliative care of people with intellectual disabilities in Europe.
Design: Delphi study in four rounds: (1) a taskforce of 12 experts from seven European countries drafted the norms, based on available empirical knowledge and regional/national guidelines; (2) using an online survey, 34 experts from 18 European countries evaluated the draft norms, provided feedback and distributed the survey within their professional networks. Criteria for consensus
were clearly defined; (3) modifications and recommendations were made by the taskforce; and (4) the European Association for
Palliative Care reviewed and approved the final version.
Setting and participants: Taskforce members: identified through international networking strategies. Expert panel: a purposive sample identified through taskforce members’ networks.
Results: A total of 80 experts from 15 European countries evaluated 52 items within the following 13 norms: equity of access, communication, recognising the need for palliative care, assessment of total needs, symptom management, end-of-life decision making, involving those who matter, collaboration, support for family/carers, preparing for death, bereavement support, education/training
and developing/managing services. None of the items scored less than 86% agreement, making a further round unnecessary. In light of respondents’ comments, several items were modified and one item was deleted.
Conclusion: This White Paper presents the first guidance for clinical practice, policy and research related to palliative care for people with intellectual disabilities based on evidence and European consensus, setting a benchmark for changes in policy and practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE:

To compare the outcomes of cataract surgery performed with 3 incision size-dependent phacoemulsification groups (1.8, 2.2, and 3.0 mm).

DESIGN:

Prospective randomized comparative study.

METHODS:

One hundred twenty eyes of 120 patients with age-related cataract (grades 2 to 4) were categorized according to the Lens Opacities Classification System III. Eligible subjects were randomly assigned to 3 surgical groups using coaxial phacoemulsification through 3 clear corneal incision sizes (1.8, 2.2, and 3.0 mm). Different intraoperative and postoperative outcome measures were obtained, with corneal incision size and surgically induced astigmatism as the main clinical outcomes.

RESULTS:

There were no statistically significant differences in most of the intraoperative and postoperative outcome measures among the 3 groups. However, the mean cord length of the clear corneal incision was increased in each group after surgery. The mean maximal clear corneal incision thickness in the 1.8-mm group was significantly greater than for the other groups at 1 month. The mean surgically induced astigmatism in the 1.8- and 2.2-mm groups was significantly less than that in the 3.0-mm group after 1 month, without significant difference between the 1.8- and 2.2-mm groups.

CONCLUSIONS:

With appropriate equipment, smaller incisions may result in less astigmatism, but the particular system used will influence incision stress and wound integrity, and may thus limit the reduction in incision size and astigmatism that is achievable.