16 resultados para CV
Resumo:
GD 552 is a cataclysmic binary which was previously believed to be composed of an M-star and a white dwarf, the latter having an extreme mass of 1.4 solar masses. In a recent paper we showed that this is not compatible with new observational evidence and presented an alternative model in which the white dwarf has a typical mass and the companion is a brown dwarf, making the system a likely member of the elusive group of CVs which have already evolved through minimum orbital period. Here we present additional spectroscopical evidence supporting this conclusion by means of skew mapping.
Resumo:
A chiral gas chromatographic assay has been developed for quantitative analysis of ethosuximide and its major metabolites in rat urine. The extraction procedure was found to be precise and reproducible. Recovery was in the range of 94-98%, intraday CV(%) was 0.92% for (S)-ethosuximide (50 mug/ml) and 0.51% for (R)-ethosuximide (50 mug/ml). Interday CV(%) was 1.12% for (S)-ethosuximide and 0.72% for (R)-ethosuximide. The limit of detection was determined to be around 0.01 mug/ml for each enantiomer. Following administration of rac-ethosuximide by i.v., i.p. and oral routes, unchanged ethosuximide was detected in urine up to 72h after drug administration. The appearance of all detected metabolites occurred Within 24h of drug administration. Significantly more (S)-ethosuximide was excreted unchanged than (R)-ethosuximide with all three routes studied. A substantial amount of the drug was eliminated as the 2-(1-hydroxyethyl)-2-methylsuccinimide (2 pairs of diastereoisomers). Much less drug was eliminated as the 2-ethyl-3-hydroxy-2-methylsuccinimide with only one diastereoisomer observed. Examination of the one pair of diastereoisomers of 2-(1-hydroxyethyl)-2-methylsuccinimide that was resolved showed preferential excretion of one isomer. Comparison of both pairs of diastereoisomers showed that one pair was formed in preference to the other with a ratio of approximately 0.8:1. It is concluded that stereoselective metabolism of ethosuximide occurs. Copyright (C) 2001 John Wiley & Sons, Ltd. Author Keywords: chiral pharmacokinetics; ethosuximide enantiomers; metabolism; rat; urinary excretion; gas chromatography
Resumo:
This article describes the development of the first ion pair solid phase extraction technique (IPSPE), which has been applied to the extraction of metformin from plasma samples. In addition an ion pair chromatographic method was developed for the specific HPLC determination of metformin. Several extraction and HPLC methods have been described previously for metformin, however, most of them did not solve the problems associated with the high polarity of this drug. Drug recovery in the developed method was found to be more than 98%. The limit of detection and limit of quantification was 3 and 5 ng/ml, respectively. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error, R.E.%) was always less than 6.9%. Stability analysis showed that metformin is stable for at least 3 months when stored at -70degreesC. The method has been applied to 150 patient samples as part of a medication adherence study. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The use of blood spot collection cards is a simple way to obtain specimens for analysis of drugs for the purpose of therapeutic drug monitoring, assessing adherence to medications and preventing toxicity in routine clinical setting. We describe the development and validation of a microanalytical technique for the determination of metformin from dried blood spots. The method is based on reversed phase high-performance liquid chromatography with ultraviolet detection. Drug recovery in the developed method was found to be more than 84%. The limits of detection and quantification were calculated to be to be 90 and 150 ng/ml, respectively. The intraday and interday precision (measured by CV%) was always less than 9%. The accuracy (measured by relative error, %) was always less than 12%. Stability analysis showed that metformin is stable for at least 2 months when stored at -70 degrees C. The small volume of blood required (10 mu L), combined with the simplicity of the analytical technique makes this a useful procedure for monitoring metformin concentrations in routine clinical settings. The method is currently being applied to the analysis of blood spots taken from diabetic patients to assess adherence to medications and relationship between metformin level and metabolic control of diabetes. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
This article describes the development of SPE and HPLC methods for the simultaneous determination of metformin and glipizide, gliclazide, glibenclamide or glimperide in plasma. Several extraction and HPLC methods have been described previously for the determination of each of these analytes in plasma separately. The simultaneous determination of these analytes is important for the routine monitoring of diabetic patients who take combination medications and for studying the pharmacokinetics of the combined dosage forms. In addition this developed method can serve as a standard method for the plasma determination of these analytes therefore saving time, effort and money. The recoveries of the developed methods were found to be between 76.3% and 101.9%. The limits of quantification were between 5 and 22.5 ng/ml. The intraday and interday precision (measured by coefficient of variation, CV%) was always less than 9%. The accuracy (measured by relative error %) was always less than 12%. Stability analysis showed that all analytes are stable for at least 3 months when stored at -70degreesC. (C) 2004 Elsevier B.V. All rights reserved.