21 resultados para CHEMICAL SENSORS
Resumo:
This paper could be consider seminal in the Civil Engineering field as it describes the first application of these sensors to a complex durability and management issue. For this reason it is potentially controversial as it requires Civil Engineers to re-evaluate the nature and scale of durability testing.
Resumo:
The road to molecular logic and computation in Belfast, Northern Ireland started with chemical sensors in Colombo, Sri Lanka. This journey is mapped out with reference to design principles, such as those for luminescent PET (photoinduced electron transfer) sensing. Applications such as those for blood electrolyte diagnostics, "lab-on-a-molecule" systems, and molecular computational identification (MCID) are also met along the way.
Resumo:
In this paper, new solutions to the problem of making measurements, of carbonation and chloride ingress, in particular, in concrete structures are considered. The approach has focused on the design, development, and use of fiber-optic sensors (FOSs), recognizing the need in that conventional devices are often either inaccurate, expensive, or unsuitable for encapsulation in the material. The sensors have been designed to monitor, in situ and nondestructively, relevant physical, and chemical changes in cementitious materials. Three different types of FOS were constructed, tested, and evaluated specifically for this application, these being a temperature sensor (based on the fluorescence decay) and pH and chloride sensors, based on sol-gel (solidified gel) technology with appropriate impregnated indicators. The sensors were all designed to be inserted into the structures and evaluated under the harshest conditions, i.e., being mounted when the mortar is poured and thus tested in situ, with the temperature and pH sensors successfully embedded in mortar. The outcomes of these tests have shown that both the temperature sensor and the pH sensor were able to function correctly for the duration of the work - for over 18 months after placement. The laboratory tests on the chloride sensor showed it was able to make measurements but was not reversible, limiting its potential utility for in situ environments. Research is ongoing to refine the sensor performance and extend the testing.
Resumo:
Plasticized and unplasticized polymer colorimetric film sensors for gaseous CO2, containing the dye m-cresol purple, are tested as sensors for dissolved CO2. The plasticized polymer m-cresol purple film sensor develops a measurable degree of opacity when exposed to aqueous solution, especially in neutral, compared with alkaline, solution. However, it is shown that a presoaked, fogged plasticized polymer m-cresol purple film does function as a quantitative sensor for dissolved CO2 over the range 0-4% CO2. An unplasticized polymer m-cresol purple film remains largely dear upon exposure to aqueous solution and also functions as a quantitative sensor for dissolved CO2 over the range 0-4% CO2. However, in both types of films the dye interacts with electrolytes present in solution; invariably the dye appears to be converted from its initial deprotonated form (blue) to its protonated form (yellow) and the rate of this process appears to increase with increasing ionic strength, anionic charge and decreasing pH. The 90% response and recovery times for an unplasticized film are determined as 19 s(CO2:0-->5%) and 21 s (CO2:5-->3.6%), respectively.
Resumo:
Weathering of stone is one of the major reasons for the damage of stone masonry structures and it takes place due to interlinked chemical, physical and biological processes in stones. The key parameters involved in the deterioration processes are temperature, moisture and salt. It is now known that the sudden variations in temperature and moisture greatly accelerate the weathering process of the building stone fabric. Therefore, in order to monitor these sudden variations an effective and continuous monitoring system is needed. Furthermore, it must consist of robust sensors which are accurate and can survive in the harsh environments experienced in and around masonry structures. Although salt penetration is important for the rate of deterioration of stone masonry structures, the processes involved are much slower than the damage associated with temperature and moisture variations. Therefore, in this paper a novel fibre optic temperature cum relative humidity sensor is described and its applicability in monitoring building stones demonstrated. The performance of the sensor is assessed in an experiment comprising wetting and drying of limestone blocks. The results indicate that the novel fibre optic relative humidity sensor which is tailor made for applications in masonry structures performed well in wetting and drying tests, whilst commercial capacitance based sensors failed to recover during the drying regime for a long period after a wetting regime. That is, the fibre optic sensor has the capability to measure both sorption and de-sorption characteristics of stone blocks. This sensor is used in a test wall in Oxford and the data thus obtained strengthened the laboratory observations.
Resumo:
Diblock copolymer vesicles are tagged with pH-responsive Nile Blue-based labels and used as a new type of pH-responsive colorimetric/fluorescent biosensor for far-red and near-infrared imaging of live cells. The diblock copolymer vesicles described herein are based on poly(2-(methacryloyloxy)ethyl phosphorylcholine-block-2-(diisopropylamino)ethyl methacrylate) [PMPC-PDPA]: the biomimetic PMPC block is known to facilitate rapid cell uptake for a wide range of cell lines, while the PDPA block constitutes the pH-responsive component that enables facile vesicle self-assembly in aqueous solution. These biocompatible vesicles can be utilized to detect interstitial hypoxic/acidic regions in a tumor model via a pH-dependent colorimetric shift. In addition, they are also useful for selective intracellular staining of lysosomes and early endosomes via subtle changes in fluorescence emission. Such nanoparticles combine efficient cellular uptake with a pH-responsive Nile Blue dye label to produce a highly versatile dual capability probe. This is in marked contrast to small molecule dyes, which are usually poorly uptaken by cells, frequently exhibit cytotoxicity, and are characterized by intracellular distributions invariably dictated by their hydrophilic/hydrophobic balance.
Resumo:
Following a brief introduction to the principle of fluorescent PET (photoinduced electron transfer) sensors and switches, the outputs of laboratories in various countries from the past year or two are categorized and critically discussed. Emphasis is placed on the molecular design and the experimental outcomes in terms of target-induced fluorescence enhancements and input/output wavelengths. The handling of single targets takes up a major fraction of the review, but the extension to multiple targets is also illustrated. Conceptually new channels of investigation are opened up by the latter approach, e.g. ‘lab-on-a-molecule’ systems and molecular keypad locks. The growing trends of theoretically-fortified design and intracellular application are pointed out.