25 resultados para Bubble
Resumo:
A hydrodynamic characterization of an industrially used gas-liquid contacting microchannel. device is discussed, viz. the micro bubble column of IMM. Furthermore, similar characterization of a gas-liquid flow microchip of TU/e, with two tailored mixer designs, is used to solve fundamental issues on hydrodynamics, and therefore, to achieve further design and operating optimization of that chip and the IMM device. Flow pattern maps are presented in a dimensionless fashion for further predictions on new fluidic systems for optimum single-channel multiphase operation. Bubble formation was investigated in the two types of mixers and pinch-off and hydrodynamic decay mechanisms are observed. The impact of these mechanisms on bubble size, bubble size distributions, and on the corresponding flow patterns, i.e., the type of mixer design, can be decisive for the flow pattern map and thus, may be used to alter flow pattern maps. The bubble sizes and their distribution were improved for the tailored designs, i.e., smaller and more regular bubbles were generated. Finally, the impact of multi-channel distribution for gas and liquid flow is demonstrated. Intermediate flow patterns such as slug-annular flow, also found for single-phase operation, and the simultaneous coexistence of flow regimes are presented, with the latter providing evidence of flow maldistribution.
Resumo:
We examine the role of the news media during the British Railway Mania, arguably one of the largest financial bubbles in history. Our analysis suggests that the press responded to changes in the stock market, and its reporting of recent events may have influenced asset prices. However, we find no evidence that the sentiment of the media, or the attention which it gave to particular stocks, had any influence on exacerbating or ending the Mania. The main contribution of the media was to provide factual information which investors could use to inform their decisions. © 2012 Elsevier Inc.
Resumo:
Sonoluminescence (SL) involves the conversion of mechanical [ultra]sound energy into light. Whilst the phenomenon is invariably inefficient, typically converting just 10-4 of the incident acoustic energy into photons, it is nonetheless extraordinary, as the resultant energy density of the emergent photons exceeds that of the ultrasonic driving field by a factor of some 10 12. Sonoluminescence has specific [as yet untapped] advantages in that it can be effected at remote locations in an essentially wireless format. The only [usual] requirement is energy transduction via the violent oscillation of microscopic bubbles within the propagating medium. The dependence of sonoluminescent output on the generating sound field's parameters, such as pulse duration, duty cycle, and position within the field, have been observed and measured previously, and several relevant aspects are discussed presently. We also extrapolate the logic from a recently published analysis relating to the ensuing dynamics of bubble 'clouds' that have been stimulated by ultrasound. Here, the intention was to develop a relevant [yet computationally simplistic] model that captured the essential physical qualities expected from real sonoluminescent microbubble clouds. We focused on the inferred temporal characteristics of SL light output from a population of such bubbles, subjected to intermediate [0.5-2MPa] ultrasonic pressures. Finally, whilst direct applications for sonoluminescent light output are thought unlikely in the main, we proceed to frame the state-of-the- art against several presently existing technologies that could form adjunct approaches with distinct potential for enhancing present sonoluminescent light output that may prove useful in real world [biomedical] applications.
Resumo:
Acute respiratory infections are the leading cause of global child mortality. In the developing world, nasal oxygen therapy is often the only treatment option for babies who are suffering from respiratory distress. Without the added pressure of bubble Continuous Positive Airway Pressure (bCPAP) which helps maintain alveoli open, babies struggle to breathe and can suffer serious complications, and frequently death. A stand-alone bCPAP device can cost $6,000, too expensive for most developing world hospitals. Here, we describe the design and technical evaluation of a new, rugged bCPAP system that can be made in small volume for a cost-of-goods of approximately $350. Moreover, because of its simple design--consumer-grade pumps, medical tubing, and regulators--it requires only the simple replacement of a <$1 diaphragm approximately every 2 years for maintenance. The low-cost bCPAP device delivers pressure and flow equivalent to those of a reference bCPAP system used in the developed world. We describe the initial clinical cases of a child with bronchiolitis and a neonate with respiratory distress who were treated successfully with the new bCPAP device.
Resumo:
A high-sample rate 3D median filtering processor architecture is proposed, based on a novel 3D median filtering algorithm, that can reduce the computing complexity in comparison with the traditional bubble sorting algorithm. A 3 x 3 x 3 filter processor is implemented in VHDL, and the simulation verifies that the processor can process a 128 x 128 x 96 MRI image in 0.03 seconds while running at 50 MHz.
Resumo:
This paper investigates if benchmark African equity indices exhibit the stylized facts reported for financial time-series returns. The returns distributions of the Africa All-Share, Large, Medium and Small Company Indices were found to be leptokurtotic, had fat-tails, over time experienced volatility clustering and exhibited long memory in volatility. Both the All-Share and Large Company Indices were found to exhibit leverage effects. In contrast, positive shocks had a greater impact on future volatility for the Small Company Index which implies a reverse leverage effect. This finding could reflect a bull/bubble market for small capitalisation stocks in Africa.
Resumo:
The sonochemical oxidation efficiency (eta(ox)) of a commercial titanium alloy ultrasound horn has been measured using potassium iodide as a dosimeter at its main resonance frequency (20 kHz) and two higher resonance frequencies (41 and 62 kHz). Narrow power and frequency ranges have been chosen to minimise secondary effects such as changing bubble stability, and time available for radical diffusion from the bubble to the liquid. The oxidation efficiency, eta(ox), is proportional to the frequency and to the power transmitted to the liquid (275 mL) in the applied power range (1-6 W) under argon. Luminol radical visualisation measurements show that the radical generation rate increases and a redistribution of radical producing zones is achieved at increasing frequency. Argon, helium, air, nitrogen, oxygen, and carbon dioxide have been used as saturation gases in potassium iodide oxidation experiments. The highest eta(ox) has been observed at 5 W under air at 62 kHz. The presence of carbon dioxide in air gives enhanced nucleation at 41 and 62 kHz and has a strong influence on eta(ox). This is supported by the luminol images, the measured dependence of eta(ox). on input power, and bubble images recorded under carbon dioxide. The results give insight into the interplay between saturation gas and frequency, nucleation, and their effect on eta(ox). (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
In this paper, a model is presented that describes the pressure drop of gas-liquid Taylor flow in round capillaries with a channel diameter typically less than 1 mm. The analysis of Bretherton (J Fluid Mech 10:166-188, 1961) for the pressure drop over a single gas bubble for vanishing liquid film thickness is extended to include a non-negligible liquid film thickness using the analysis of Aussillous and Qu,r, (Phys Fluids 12(10):2367-2371, 2000). This result is combined with the Hagen-Poiseuille equation for liquid flow using a mass balance-based Taylor flow model previously developed by the authors (Warnier et al. in Chem Eng J 135S:S153-S158, 2007). The model presented in this paper includes the effect of the liquid slug length on the pressure drop similar to the model of Kreutzer et al. (AIChE J 51(9):2428-2440, 2005). Additionally, the gas bubble velocity is taken into account, thereby increasing the accuracy of the pressure drop predictions compared to those of the model of Kreutzer et al. Experimental data were obtained for nitrogen-water Taylor flow in a round glass channel with an inner diameter of 250 mu m. The capillary number Ca (gl) varied between 2.3 x 10(-3) and 8.8 x 10(-3) and the Reynolds number Re (gl) varied between 41 and 159. The presented model describes the experimental results with an accuracy of +/- 4% of the measured values.
Resumo:
UVES interstellar observations from the Paranal Observatory Project are presented for early-type stars located in the line of sight to the nearby open clusters IC 2391 (Omni Vel) and NGC 6475 (M7), with spectroscopic resolution R similar to 80 000 and signal-to-noise ratios in the Ti II (3383 angstrom), Ca II K, CH+ (4232 angstrom), Na I D and K I (7698 angstrom) lines of several hundred. The sightlines are a mixture of cluster and non-cluster objects. A total of 22 early-type stars (A and B type) are present in our sample towards IC 2391, with 21 towards NGC 6475/M7, and enable us to probe for differences in column density on scales from similar to 0.07 to 7.3 and similar to 0.05 to 4.9 pc in the respective clusters. Additionally, towards Praesepe the Na I D interstellar variation only is probed towards 13 sightlines and transverse scales of similar to 0.16-10.7 pc at R = 70 000. Towards IC 2391 variations are found in Ti II, Ca II K and Na I D column density in different sightlines of up to 0.7, 1.0 and 1.8 dex (excluding one star), respectively. This kind of variability correlates well with the Hipparcos parallax of the objects, and probes structure within the Local Bubble. For cluster-only objects the variations are 0.3, 0.3 and 0.5 dex, respectively. For the field of view towards NGC6475 the corresponding maximum variations are somewhat smaller, being 0.5, 0.3, 0.8 and 1.0 dex for Ti II, Ca II K, Na I and K I, respectively, for all objects and 0.4, 0.2, 0.6 and 0.7 dex for the cluster-only objects. These are uncorrelated with parallax, and again demonstrate that Ca II K tends to be more smoothly distributed than Na I D. A few likely cluster sightlines show evidence for CH+ and variations in this molecular species of a factor of 10 in equivalent width over sub-pc scales. Towards Praesepe variation in interstellar Na I D is small, being a maximum of only similar to 0.4 dex (including measurement errors), but with fewer sightlines studied. Overall, the scatter in the data is similar for the singly ionized species Ti II and Ca II, lending more support to the hypothesis that these two species sample similar parts of the interstellar medium (ISM). This also appears to be the case for the neutral species Na I D and K I in the one cluster studied. Finally, multiple-epoch observations from a variety of archive sources are used to search for astronomical unit (au) scale structure in the ISM towards 46 sightlines. There are tentative indications of structure on scales of tens to thousands of au for three sightlines. Future observations will confirm the veracity or otherwise of the time-variable components and others presented.
Resumo:
Decreasing the constriction size and residence time in hydrodynamic cavitation is predicted to give increased hot spot temperatures at bubble collapse and increased radical formation rate. Cavitation in a 100 x 100 mu m(2) rectangular micro channel and in a circular 750 mu m diameter milli channel has been investigated with computational fluid dynamics software and with imaging and radical production experiments. No radical production has been measured in the micro channel. This is probably because there is no spherically symmetrical collapse of the gas pockets in the channel which yield high hot spot temperatures. The potassium iodide oxidation yield in the presence of chlorohydrocarbons in the milli channel of up to 60 nM min(-1) is comparable to values reported on hydrodynamic cavitation in literature, but lower than values for ultrasonic cavitation. These small constrictions can create high apparent cavitation collapse frequencies.
Resumo:
Scission of a supramolecular polymer-metal complex can be carried out using collapsing cavitation bubbles created by ultrasound. Although the most plausible scission mechanism of the coordinative bonds is through mechanical force, the influence of radicals and high hot-spot temperatures on scission has to be considered. A silver(I)-N-heterocyclic carbene complex was exposed to 20 kHz ultrasound in argon, nitrogen, methane, and isobutane saturated toluene. Scission percentages were almost equal under argon, nitrogen, and methane. Radical production differs by a factor of 10 under these gases, indicating that radical production is not a significant contributor to the scission process. A model to describe the displacement of the bubble wall, strain rates, and temperature in the gas shows that critical strain rates for coil-to-stretch transition, needed for scission, are achieved at reactor temperatures of 298 K, an acoustic pressure of 1.2 x 10(5) Pa, and an acoustic frequency of 20 kHz. Lower scission percentages were measured under isobutane, which also shows lower strain rates in model simulations. The activation of the polymer-metal complexes in toluene under the influence of ultrasound occurs through mechanical force.
Resumo:
This article addresses the relative absence of class-based analysis in theatre and performance studies, and suggests the reconfiguration of class as performance rather than as it is traditionally conceived as an identity predicated solely on economic stratification. It engages with the occlusion of class by the ascendancy of identity politics based on race, gender and sexuality and its attendant theoretical counterparts in deconstruction and post-structuralism, which became axiomatic as they displaced earlier methodologies to become hegemonic in the arts and humanities. The article proceeds to an assessment of the development of sociological approaches to theatre, particularly the legacy of Raymond Williams and Pierre Bourdieu. The argument concludes with the application of an approach which reconfigures class as performance to the production of Declan Hughes's play Shiver of 2003, which dramatizes the consequences of the dot.com bubble of the late 1990s for ambitious members of the Irish middle class.
Resumo:
Gas-liquid processing in microreactors remains mostly restricted to the laboratory scale due to the complexity and expenditure needed for an adequate numbering-up with a uniform flow distribution. Here, the numbering-up is presented for multi-phase (gas-liquid) flow in microreactor suitable for a production capacity of kg/h. Based on the barrier channels concept, the barrier-based micro/milli reactor (BMMR) is designed and fabricated to deliver flow non-uniformity of less than 10%. The BMMR consists of eight parallel channels all operated in the Taylor flow regime and with a liquid flow rate up to 150. mL/min. The quality of the flow distribution is reported by studying two aspects. The first aspect is the influence of different viscosities, surface tensions and flow rates. The second aspect is the influence of modularity by testing three different reaction channels type: (1) square channels fabricated in a stainless steel plate, (2) square channels fabricated in a glass plate, and (3) circular channels (capillaries) made of stainless steel. Additionally, the BMMR is compared to that of a single channel regard the slug and bubble lengths and bubble generation frequency. The results pave the ground for bringing multi-phase flow in microreactor one step closer for large scale production via numbering-up. © 2012 Elsevier B.V.
Resumo:
PURPOSE: To report the use of perfluorohexyloctane, a liquid semifluorinated alkane that is heavier than water, as an internal tamponade agent in surgery for complicated retinal detachments. DESIGN: A consecutive interventional case series from three study centers. METHODS: In 23 consecutive eyes (23 patients, 19 men and four women, mean ± standard deviation (SD) age of 58.5 years ± 16.1) perfluorohexyloctane was used for long-term internal tamponade. Included were eyes with complicated retinal detachment involving the lower two quadrants of the fundus. Excluded were patients with diseases in the fellow eye or severe systemic disease. A pars plana vitrectomy was performed, including membrane peeling and retinotomy where necessary. RESULTS: The mean duration for perfluorohexyloctane being left in situ was 76 days (SD 37.64) (range, 35-202 days). Four weeks following the removal of perfluorohexyloctane 19 of the 23 patients had total reattachment of the retina; three eyes had a recurrence of retinal detachment. One patient was lost to follow-up. The mean follow-up after perfluorohexyloctane removal was 97 days (range, 48 to 169 days). Cataract formation or progression was noted in nine of the 10 eyes. There were two cases with high intraocular pressures. Dispersion into small droplets was observed as early as 3 days postoperatively in three of the 23 patients. At least 12 of the 23 patients had an obvious dispersion by the time of perfluorohexyloctane removal. There was no sign of optic atrophy, retinal necrosis, or retinal vascular occlusion. CONCLUSION: Perfluorohexyloctane was tolerated as a long-term internal tamponade agent without obvious signs of damage to the retina or optic disk. Of all the complications noted, the most common was that of dispersion of the perfluorohexyloctane bubble into droplets. © 2002 by Elsevier Science Inc. All rights reserved.