40 resultados para 604


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-cadence multiwavelength optical observations were taken with the Dunn Solar Telescope at the National Solar Observatory, Sacramento Peak, accompanied by Advanced Stokes Polarimeter vector magnetograms. A total of 11 network bright points (NBPs) have been studied at different atmospheric heights using images taken in wave bands centered on Mg I b(1) - 0.4 Angstrom, Halpha, and Ca II K-3. Wavelet analysis was used to study wave packets and identify traveling magnetohydrodynamic waves. Wave speeds were estimated through the temporal cross-correlation of signals, in selected frequency bands of wavelet power, in each wavelength. Four mode-coupling cases were identified, one in each of four of the NBPs, and the variation of the associated Fourier power with height was studied. Three of the detected mode-coupling, transverse-mode frequencies were observed in the 1.2-1.6 mHz range (mean NBP apparent flux density magnitudes over 99-111 Mx cm(-2)), with the final case showing 2.0-2.2 mHz (with 142 Mx cm(-2)). Following this, longitudinal-mode frequencies were detected in the range 2.6-3.2 mHz for three of our cases, with 3.9-4.1 mHz for the remaining case. After mode coupling, two cases displayed a decrease in longitudinal-mode Fourier power in the higher chromosphere.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An alternative method for monitoring protein-protein interactions in Saccharomyces cerevisiae has been developed. It relies on the ability of two fragments of enhanced green fluorescent protein (EGFP) to reassemble and fluoresce when fused to interacting proteins. Since this fluorescence can be detected in living cells, simultaneous detection and localisation of interacting pairs is possible. DNA sequences encoding N- and C-terminal EGFP fragments flanked by sequences from the genes of interest were transformed into S. cerevisicie JPY5 cells and homologous recombination into the genome verified by PCR. The system was evaluated by testing known interacting proteins: labelling of the phosphofructokinase subunits, Pfk1p and Pfk2p, with N- and C-terminal EGFP fragments, respectively, resulted in green fluorescence in the cytoplasm. The system works in other cellular compartments: labelling of Idh1p and Idh2p, (mitochondrial matrix), Sdh3p and Sdh4p (mitochondrial membrane) and Pap2p and Mtr4p (nucleus) all resulted in fluorescence in the appropriate cellular compartment. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[Ag(NH3)(2)](ClO4) is obtained from a solution of AgClO4 in cone. ammonia as colourless single crystals (orthorhombic, Pnmn, Z = 4, a = 795.2(1) pm, b 617.7(1) pm, c = 1298.2(2) pm, R-all = 0.0494). The structure consists of linearly coordinated cations, [Ag(NH3)(2)](+), stacked in a staggered conformation and of tetrahedral (ClO4)(-) anions. A first order phase transition was observed between 210 and 200 K and the crystal structure of the low-temperature modification (monoclinic. P2/m, Z = 4, a = 789.9(5) pm, b = 604.1(5) pm, c = 1290.4(5) pm, beta = 97.436(5)degrees, at 170 K, R-all = 0.0636) has also been solved. Spectroscopic investigations (IR/Raman) have been carried out and the assignment of the spectra is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method is discussed for measuring the acoustic impedance of tubular objects that gives accurate results for a wide range of frequencies. The apparatus that is employed is similar to that used in many previously developed methods; it consists of a cylindrical measurement duct fitted with several microphones, of which two are active in each measurement session, and a driver at one of its ends. The object under study is fitted at the other end. The impedance of the object is determined from the microphone signals obtained during excitation of the air inside the 1 duct by the driver, and from three coefficients that are pre-determined using four calibration measurements with closed cylindrical tubes. The calibration procedure is based on the simple mathematical relationships between the impedances of the calibration tubes, and does not require knowledge of the propagation constant. Measurements with a cylindrical tube yield an estimate of the attenuation constant for plane waves, which is found to differ from the theoretical prediction by less than 1.4% in the frequency range 1 kHz-20 kHz. Impedance measurements of objects with abrupt changes in diameter are found to be in good agreement with multimodal theory.

Relevância:

10.00% 10.00%

Publicador: