41 resultados para liquid propertiesi measurement cell

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new approach to the search for residues of unknown growth promoting agents such as anabolic steroids and -agonists in feed is presented. Following primary extraction and clean-up, samples are separated using gradient liquid chromatography (LC). The effluent is split towards two identical 96-well fraction collectors and an optional electrospray quadrupole time-of-flight mass spectrometry (QTOFMS) system for accurate mass measurement. One 96-well plate is used for a bioassay (enzyme-immuno assay, receptor assay) and will detect the bioactivity and position of the relevant peak in the chromatogram. The positive well in the second 96-well plate is used for identification by LC/QTOFMS/MS. The value of this LC/bioassay/QTOFMS/MS methodology is highlighted by the finding and structure elucidation of a new -agonist in a feed extract.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Numerical simulations are used to study the electromagnetic scattering from phase agile microstrip reflectarray cells which exploit the voltage controlled dielectric anisotropy property of nematic state liquid crystals (LC). In the computer model two arrays of equal size elements constructed on a 15?m thick tuneable LC layer were designed to operate at centre frequencies of 102 GHz and 130 GHz. Micromachining processes based on the metallization of quartz/silicon wafers and an industry compatible LCD packaging technique were employed to fabricate the grounded periodic structures. The loss and phase of the reflected signals were measured using a quasi-optical test bench with the reflectarray cells inserted at the beam waist of the imaged Gaussian beam, thus eliminating some of the major problems associated with traditional free-space characterisation at these frequencies. By applying a low frequency AC bias voltage of 10 V, a 165o phase shift with a loss 4.5 dB-6.4 dB at 102 GHz and 130o phase shift with a loss variation between 4.3 dB – 7 dB at 130 GHz was obtained. The experimental results are shown to be in close agreement with the computer model.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The mouse spleen cell assay (MSCA) has been compared with a radioimmunoassay for the measurement of serum erythropoietin (Ep). In 20 normal subjects the serum values ranged from 15 to 73 mU/ml for the MSCA compared with 5-30 mU/ml for the RIA. For normal sera there was no correlation between the results of the two assays. In 37 patients with anaemias of differing aetiologies and at various stages of treatment values ranged from 10 to 3645 mU/ml for the MSCA and 13-10,000 mU/ml for the RIA. Although patient values from the two assays were highly correlated (r = 0.98, P less than 0.001), the MSCA results were generally lower. These discrepancies can be largely accounted for by two factors. Firstly the MSCA is sensitive to non-specific matrix effects. Secondly, heat inactivation of serum, a prerequisite for the MSCA, but not for the RIA, destroys a variable and unpredictable proportion of the Ep in the test sera leading to an underestimation of Ep in the MSCA. We conclude that the RIA is more reliable than the MSCA which, in its present form, cannot be recommended for the accurate measurement of serum erythropoietin.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Most liquid electrolytes used in commercial lithium-ion batteries are composed by alkylcarbonate mixture containing lithium salt. The decomposition of these solvents by oxidation or reduction during cycling of the cell, induce generation of gases (CO2, CH4, C2H4, CO …) increasing of pressure in the sealed cell, which causes a safety problem [1]. The prior understanding of parameters, such as structure and nature of salt, temperature pressure, concentration, salting effects and solvation parameters, which influence gas solubility and vapor pressure of electrolytes is required to formulate safer and suitable electrolytes especially at high temperature.

We present in this work the CO2, CH4, C2H4, CO solubility in different pure alkyl-carbonate solvents (PC, DMC, EMC, DEC) and their binary or ternary mixtures as well as the effect of temperature and lithium salt LiX (X = LiPF6, LiTFSI or LiFAP) structure and concentration on these properties. Furthermore, in order to understand parameters that influence the choice of the structure of the solvents and their ability to dissolve gas through the addition of a salt, we firstly analyzed experimentally the transport properties (Self diffusion coefficient (D), fluidity (h-1), and conductivity (s) and lithium transport number (tLi) using the Stock-Einstein, and extended Jones-Dole equations [2]. Furthermore, measured data for the of CO2, C2H4, CH4 and CO solubility in pure alkylcarbonates and their mixtures containing LiPF6; LiFAP; LiTFSI salt, are reported as a function of temperature and concentration in salt. Based on experimental solubility data, the Henry’s law constant of gases in these solvents and electrolytes was then deduced and compared with values predicted by using COSMO-RS methodology within COSMOthermX software. From these results, the molar thermodynamic functions of dissolution such as the standard Gibbs energy, the enthalpy, and the entropy, as well as the mixing enthalpy of the solvents and electrolytes with the gases in its hypothetical liquid state were calculated and discussed [3]. Finally, the analysis of the CO2 solubility variations with the salt addition was then evaluated by determining specific ion parameters Hi by using the Setchenov coefficients in solution. This study showed that the gas solubility is entropy driven and can been influenced by the shape, charge density, and size of the anions in lithium salt.

References

[1] S.A. Freunberger, Y. Chen, Z. Peng, J.M. Griffin, L.J. Hardwick, F. Bardé, P. Novák, P.G. Bruce, Journal of the American Chemical Society 133 (2011) 8040-8047.

[2] P. Porion, Y.R. Dougassa, C. Tessier, L. El Ouatani, J. Jacquemin, M. Anouti, Electrochimica Acta 114 (2013) 95-104.

[3] Y.R. Dougassa, C. Tessier, L. El Ouatani, M. Anouti, J. Jacquemin, The Journal of Chemical Thermodynamics 61 (2013) 32-44.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electro-optic response of a cell consisting of a thin layer of liquid crystal deposited onto gold nanorods embedded in thin film alumina with a transparent top electrode has been investigated. For p-polarized light incident from the liquid crystal side, the extinction peak associated with the nanorod longitudinal plasmon resonance is completely suppressed. The peak could be recovered by applying an external electric field parallel to the long axis of the nanorods. No extinction peak suppression is observed when the light was incident from the nanorod side of the cell. The effect is explained by polarization properties of liquid crystal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental investigation of the argon plasma behavior near the E-H transition in an inductively coupled Gaseous Electronics Conference reference cell is reported. Electron density and temperature, ion density, argon metastable density, and optical emission measurements have been made as function of input power and gas pressure. When plotted versus plasma power, applied power corrected for coil and hardware losses, no hysteresis is observed in the measured plasma parameter dependence at the E-H mode transition. This suggests that hysteresis in the E-H mode transition is due to ignoring inherent power loss, primarily in the matching system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental results at X-band are used to compare the electromagnetic scattering from a printed reflectarray cell, which is constructed on 500 mu m thick layers of three different nematic state liquid crystals. It is shown that a small voltage can be used to vary the permittivity of the tunable substrate and thereby control the phase of the reflected signals. Numerical results using Ansoft HFSS are compared with the measured phase, resonant frequencies and signal attenuation for two orientations of the liquid crystal molecules. Data fitting is employed to quantify the loss tangent and the permittivity values of the three anisotropic specimens. The performance trade-offs that are imposed by the use of commercially available materials are discussed, and the computer model is used to specify the electrical properties of a liquid crystal mixture, which can provide a signal loss of <1 dB and a dynamic phase range of 300 degrees from the patch elements at 10 GHz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quartz crystal impedance analysis has been developed as a technique to assess whether room-temperature ionic liquids are Newtonian fluids and as a small-volume method for determining the values of their viscosity-density product, rho eta. Changes in the impedance spectrum of a 5-MHz fundamental frequency quartz crystal induced by a water-miscible room-temperature ionic liquid, 1-butyl-3-methylimidazolium. trifluoromethylsulfonate ([C(4)mim][OTf]), were measured. From coupled frequency shift and bandwidth changes as the concentration was varied from 0 to 100% ionic liquid, it was determined that this liquid provided a Newtonian response. A second water-immiscible ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [C(4)mim][NTf2], with concentration varied using methanol, was tested and also found to provide a Newtonian response. In both cases, the values of the square root of the viscosity-density product deduced from the small-volume quartz crystal technique were consistent with those measured using a viscometer and density meter. The third harmonic of the crystal was found to provide the closest agreement between the two measurement methods; the pure ionic liquids had the largest difference of similar to 10%. In addition, 18 pure ionic liquids were tested, and for 11 of these, good-quality frequency shift and bandwidth data were obtained; these 12 all had a Newtonian response. The frequency shift of the third harmonic was found to vary linearly with square root of viscosity-density product of the pure ionic liquids up to a value of root(rho eta) approximate to 18 kg m(-2) s(-1/2), but with a slope 10% smaller than that predicted by the Kanazawa and Gordon equation. It is envisaged that the quartz crystal technique could be used in a high-throughput microfluidic system for characterizing ionic liquids.