33 resultados para integrity in closed-loop

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper is to increase the performance of hysteresis compensation for Shape Memory Alloy (SMA) actuators by using inverse Preisach model in closed — loop control system. This is used to reduce hysteresis effects and improve accuracy for the displacement of SMA actuators. Firstly, hysteresis is identified by numerical Preisach model implementation. The geometrical interpretation from first order transition curves is used for hysteresis modeling. Secondly, the inverse Preisach model is formulated and incorporated in closed-loop PID control system in order to obtain desired current-to-displacement relationship with hysteresis reducing. The experimental results for hysteresis compensation by using this method are also shown in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Researchers and managers broadly agree that original equipment manufacturers (OEMs), which have opportunities to produce both new and remanufactured products, are better off by centrally controlling their manufacturing and remanufacturing activities. Thus, OEMs should not remanufacture used products until the remanufacturing cost is sufficiently low to overcome the negative impact of new product cannibalisation. In this paper, we present a contrasting view of the manufacturing–remanufacturing conflict: OEMs sometimes benefit from the decentralised control mode under which they ignore the internal cannibalisation rather than the remanufacturing option. We consider a decentralised closed-loop supply chain in which one OEM can purchase new components from one supplier to produce new products and collect used products from consumers to produce remanufactured products. The key feature of our model is that the OEM can select a centralised or decentralised control mode to manage its manufacturing and remanufacturing activities before the supplier prices the new component. In a steady state period setting, we analyse the players’ optimal decisions and compare the OEM's profits under centralised and decentralised control modes. Our analytic results reveal that the decentralised control within the OEM can outperform the centralised control when the cost structure of producing new and remanufactured products satisfies certain conditions. Finally, the key findings are distilled in a conceptual framework and its managerial implications are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces a novel modelling framework for identifying dynamic models of systems that are under feedback control. These models are identified under closed-loop conditions and produce a joint representation that includes both the plant and controller models in state space form. The joint plant/controller model is identified using subspace model identification (SMI), which is followed by the separation of the plant model from the identified one. Compared to previous research, this work (i) proposes a new modelling framework for identifying closed-loop systems, (ii) introduces a generic structure to represent the controller and (iii) explains how that the new framework gives rise to a simplified determination of the plant models. In contrast, the use of the conventional modelling approach renders the separation of the plant model a difficult task. The benefits of using the new model method are demonstrated using a number of application studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Focusing on the uplink, where mobile users (each with a single transmit antenna) communicate with a base station with multiple antennas, we treat multiple users as antennas to enable spatial multiplexing across users. Introducing distributed closed-loop spatial multiplexing with threshold-based user selection, we propose two uplink channel-assigning strategies with limited feedback. We prove that the proposed system also outperforms the standard greedy scheme with respect to the degree of fairness, measured by the variance of the time averaged throughput. For uplink multi-antenna systems, we show that the proposed scheduling is a better choice than the greedy scheme in terms of the average BER, feedback complexity, and fairness. The numerical results corroborate our findings

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose a low-complexity closed-loop spatial multiplexing method with limited feedback over multi-input-multi-output (MIMO) fading channels. The transmit adaptation is simply performed by selecting transmit antennas (or substreams) by comparing their signal-to-noise ratios to a given threshold with a fixed nonadaptive constellation and fixed transmit power per substream. We analyze the performance of the proposed system by deriving closed-form expressions for spectral efficiency, average transmit power, and bit error rate (BER). Depending on practical system design constraints, the threshold is chosen to maximize the spectral efficiency (or minimize the average BER) subject to average transmit power and average BER (or spectral efficiency) constraints, respectively. We present numerical and Monte Carlo simulation results that validate our analysis. Compared to open-loop spatial multiplexing and other approaches that select the best antenna subset in spatial multiplexing, the numerical results illustrate that the proposed technique obtains significant power gains for the same BER and spectral efficiency. We also provide numerical results that show improvement over rate-adaptive orthogonal space-time block coding, which requires highly complex constellation adaptation. We analyze the impact of feedback delay using analytical and Monte Carlo approaches. The proposed approach is arguably the simplest possible adaptive spatial multiplexing system from an implementation point of view. However, our approach and analysis can be extended to other systems using multiple constellations and power levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple approach is proposed for disturbance attenuation in multivariable linear systems via dynamical output compensators based on complete parametric eigenstructure assignment. The basic idea is to minimise the H-2 norm of the disturbance-output transfer function using the design freedom provided by eigenstructure assignment. For robustness, the closed-loop system is restricted to be nondefective. Besides the design parameters, the closed-loop eigenvalues are also optimised within desired regions on the left-half complex plane to ensure both closed-loop stability and dynamical performance. With the proposed approach, additional closed-loop specifications can be easily achieved. As a demonstration, robust pole assignment, in the sense that the closed-loop eigenvalues are as insensitive as possible to open-loop system parameter perturbations, is treated. Application of the proposed approach to robust control of a magnetic bearing with a pair of opposing electromagnets and a rigid rotor is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over 60 years ago, Charles Kittel predicted that quadrant domains should spontaneously form in small ferromagnetic platelets. He expected that the direction of magnetization within each quadrant should lie parallel to the platelet surface, minimizing demagnetizing fields, and that magnetic moments should be configured into an overall closed loop, or flux-closure arrangement. Although now a ubiquitous observation in ferromagnets, obvious flux-closure patterns have been somewhat elusive in ferroelectric materials. This is despite the analogous behaviour between these two ferroic subgroups and the recent prediction of dipole closure states by atomistic simulations research. Here we show Piezoresponse Force Microscopy images of mesoscopic dipole closure patterns in free-standing, single-crystal lamellae of BaTiO3. Formation of these patterns is a dynamical process resulting from system relaxation after the BaTiO3 has been poled with a uniform electric field. The flux-closure states are composed of shape conserving 90° stripe domains which minimize disclination stresses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Domain states in PbZr(0.42)Ti(0.58)O3 single-crystal ferroelectric nanodots, formed on cooling through the Curie temperature, were imaged by transmission electron microscopy. In the majority of cases, 90o stripe domains were found to form into four distinct “bundles” or quadrants. Detailed analysis of the dipole orientations in the system was undertaken, using both dark-field imaging and an assumption that charged domain walls were energetically unfavorable in comparison to uncharged walls. On this basis, we conclude that the dipoles in these nanodots are arranged such that the resultant polarizations, associated with the four quadrant domain bundles, form into a closed loop. This “polarization closure” pattern is reminiscent of the flux-closure already commonly observed in soft ferromagnetic microdots but to date unseen in analogous ferroelectric dots.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, an automatic Smart Irrigation Decision Support System, SIDSS, is proposed to manage irrigation in agriculture. Our system estimates the weekly irrigations needs of a plantation, on the basis of both soil measurements and climatic variables gathered by several autonomous nodes deployed in field. This enables a closed loop control scheme to adapt the decision support system to local perturbations and estimation errors. Two machine learning techniques, PLSR and ANFIS, are proposed as reasoning engine of our SIDSS. Our approach is validated on three commercial plantations of citrus trees located in the South-East of Spain. Performance is tested against decisions taken by a human expert.