Objectives: The purpose of this investigation was to determine for dispensed multiples (1 through 4) of powder (P) and liquid (L) in hand-mixed dental cement whether: (1) the mean (P/L) ratio (m/m) and (2) the maximum difference in (P/L) ratio is dependent on the number of multiples dispensed. The Null hypotheses were: (a) mean (P/L) ratio is independent of the number of multiples dispensed and (b) maximum difference in (P/L) ratio is independent of the number of multiples dispensed.
Methods: The materials investigated are listed in the Table. The masses of dispensed aliquots of powder and liquid were measured by a single operator (n=10, for multiples 1 through 4) on a 4-place analytical balance. All measurements were made independently and all possible (P/L) ratios calculated for each sample. The effect of multiple dispensations on (P/L) ratios and maximum (P/L) differences was by one-way ANOVA and linear regression, respectively, with the Tukey post-hoc correction for multiple comparisons.MULTIPLE DISPENSEDDISPENSED MU(x1)(x2)(x3)(x4)Zinc phosphateHeraeus12.271(0.691)a13.051(1.269)b13.215(0.824)b13.118(1.149)bFuji IXGC4.209(0.373)a4.085(0.275)b4.095(0.226)b4.095(0.217)bIRMDentsply7.933(0.767)a7.430(0.451)b7.977(0.729)a8.186(0.929)aKetac-Cem3M Espe9.6206(0.613)a9.714(0.523)a9.298(0.314)b9.321(0.292)bMean (SD) powder/liquid ratio (m/m). Superscript letters represent significances (α = 0.05) within each material
Results: Mean (SD) (P/L) ratios are presented in the Table. Null hypothesis (a) is rejected: either (x1) or (x2) dispensation yields a different (P/L) ratio to (x3) or (x4) (p < 0.05). Null hypothesis (b) is rejected: a negative correlation is observed in max (P/L) ratio difference with dispensed multiple for Ketac Cem (p = 0.029).
Conclusion: For hand-mixed dental cements: (1) more consistent (P/L) ratios may be observed with multiple dispensations of powder & liquid; (2) maximum differences in (P/L) ratio may be negatively correlated with dispensation multiple in some materials.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A small minority of systemic lupus erythematosus (SLE) patients may develop a deforming arthritis, typically with a non-erosive (Jaccoud's) pattern, although erosive features indistinguishable from rheumatoid arthritis may also occur. High-resolution ultrasonography (HRUS) allows detailed 'real time' imaging of joint and tendon morphostructural changes involving the hand in patients with several rheumatic diseases. The main aim of this pictorial essay is to provide the first descriptive HRUS and power Doppler (PD) findings of joint and tendon involvement of the hand and wrist in patients with SLE arthritis. Seventeen patients with SLE and hand involvement were examined. HRUS of the wrist, 2nd and 3rd MCP joints, 3rd PIP joint and 2nd, 3rd and 4th finger flexor tendons were studied in the dominant hand for each patient. Sixteen (94%) patients had joint effusion or synovial hypertrophy in the wrist. Twelve (71%) patients had joint effusion or synovial hypertrophy in 2nd or 3rd MCPJs. Eight (47%) patients had erosion at 2nd or 3rd MCPJs. In three cases erosions were not present radiologically. Eleven (65%) patients had evidence of tenosynovitis. In SLE, HRUS with PD detects a high prevalence of inflammatory pathology in the tendons and synovium of the hand and wrist, and a high prevalence of MCP joint erosions. HRUS offers a sensitive, real-time and readily repeatable assessment of soft-tissue, inflammatory and bony changes in SLE hands.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. This paper is a report of a study to describe how treatment fidelity is being enhanced and monitored, using a model from the National Institutes of Health Behavior Change Consortium. Background. The objective of treatment fidelity is to minimize errors in interpreting research trial outcomes, and to ascribe those outcomes directly to the intervention at hand. Treatment fidelity procedures are included in trials of complex interventions to account for inferences made from study outcomes. Monitoring treatment fidelity can help improve study design, maximize reliability of results, increase statistical power, determine whether theory-based interventions are responsible for observed changes, and inform the research dissemination process. Methods. Treatment fidelity recommendations from the Behavior Change Consortium were applied to the SPHERE study (Secondary Prevention of Heart DiseasE in GeneRal PracticE), a randomized controlled trial of a complex intervention. Procedures to enhance and monitor intervention implementation included standardizing training sessions, observing intervention consultations, structuring patient recall systems, and using written practice and patient care plans. The research nurse plays an important role in monitoring intervention implementation. Findings. Several methods of applying treatment fidelity procedures to monitoring interventions are possible. The procedure used may be determined by availability of appropriate personnel, fiscal constraints, or time limits. Complex interventions are not straightforward and necessitate a monitoring process at trial stage. Conclusion. The Behavior Change Consortium’s model of treatment fidelity is useful for structuring a system to monitor the implementation of a complex intervention, and helps to increase the reliability and validity of evaluation findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose
– Information science has been conceptualized as a partly unreflexive response to developments in information and computer technology, and, most powerfully, as part of the gestalt of the computer. The computer was viewed as an historical accident in the original formulation of the gestalt. An alternative, and timely, approach to understanding, and then dissolving, the gestalt would be to address the motivating technology directly, fully recognizing it as a radical human construction. This paper aims to address the issues.

Design/methodology/approach
– The paper adopts a social epistemological perspective and is concerned with collective, rather than primarily individual, ways of knowing.

Findings
– Information technology tends to be received as objectively given, autonomously developing, and causing but not itself caused, by the language of discussions in information science. It has also been characterized as artificial, in the sense of unnatural, and sometimes as threatening. Attitudes to technology are implied, rather than explicit, and can appear weak when articulated, corresponding to collective repression.

Research limitations/implications
– Receiving technology as objectively given has an analogy with the Platonist view of mathematical propositions as discovered, in its exclusion of human activity, opening up the possibility of a comparable critique which insists on human agency.

Originality/value
– Apprehensions of information technology have been raised to consciousness, exposing their limitations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical windows of acetonitrile solutions doped with 0.1 m concentrations of several ionic liquids were examined by cyclic voltammetry at gold and platinum microelectrodes. These results were compared with those observed in the commonly used 0.1 m tetrabutylammonium perchlorate/acetonitrile system as well as with neat ionic liquids. The use of a trifluorotris(pentofluoroethyl)phosphate-based ionic liquid, specifically, as supporting electrolyte in acetonitrile solutions affords a wider anodic window, which is attributed to the high stability of the anionic component of these intrinsically conductive and thermally robust compounds.