28 resultados para computerized electrocardiogram

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two group practices based in a city health centre decided to prescribe non-steroidal anti-inflammatory drugs in generic form from an agreed date. The practices' computer was used to identify the number of repeat prescriptions being issued for this group of drugs and to monitor the effectiveness of the changeover. Although both practices showed a marked increase in the level of generic prescribing there was considerable interpractice variation. Generic prescribing for one practice increased from 4% to 64% and for the other from 1% to 38% of repeat prescriptions issued for non-steroidal anti-inflammatory drugs over the study period. The reasons for this variation, the advantages of computerized audit and the problems associated with this self-imposed audit are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?

DESIGN: Animal study.

SETTING: University research laboratory.

SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.

INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).

MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).

CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wearable devices performing advanced bio-signal analysis algorithms are aimed to foster a revolution in healthcare provision of chronic cardiac diseases. In this context, energy efficiency is of paramount importance, as long-term monitoring must be ensured while relying on a tiny power source. Operating at a scaled supply voltage, just above the threshold voltage, effectively helps in saving substantial energy, but it makes circuits, and especially memories, more prone to errors, threatening the correct execution of algorithms. The use of error detection and correction codes may help to protect the entire memory content, however it incurs in large area and energy overheads which may not be compatible with the tight energy budgets of wearable systems. To cope with this challenge, in this paper we propose to limit the overhead of traditional schemes by selectively detecting and correcting errors only in data highly impacting the end-to-end quality of service of ultra-low power wearable electrocardiogram (ECG) devices. This partition adopts the protection of either significant words or significant bits of each data element, according to the application characteristics (statistical properties of the data in the application buffers), and its impact in determining the output. The proposed heterogeneous error protection scheme in real ECG signals allows substantial energy savings (11% in wearable devices) compared to state-of-the-art approaches, like ECC, in which the whole memory is protected against errors. At the same time, it also results in negligible output quality degradation in the evaluated power spectrum analysis application of ECG signals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid tryptophan (Trp) depletion (RTD) has been reported to cause deterioration in the quality of decision making and impaired reversal learning, while leaving attentional set shifting relatively unimpaired. These findings have been attributed to a more powerful neuromodulatory effect of reduced 5-HT on ventral prefrontal cortex (PFC) than on dorsolateral PFC. In view of the limited number of reports, the aim of this study was to independently replicate these findings using the same test paradigms. Healthy human subjects without a personal or family history of affective disorder were assessed using a computerized decision making/gambling task and the CANTAB ID/ED attentional set-shifting task under Trp-depleted (n=17; nine males and eight females) or control (n=15; seven males and eight females) conditions, in a double-blind, randomized, parallel-group design. There was no significant effect of RTD on set shifting, reversal learning, risk taking, impulsivity, or subjective mood. However, RTD significantly altered decision making such that depleted subjects chose the more likely of two possible outcomes significantly more often than controls. This is in direct contrast to the previous report that subjects chose the more likely outcome significantly less often following RTD. In the terminology of that report, our result may be interpreted as improvement in the quality of decision making following RTD. This contrast between studies highlights the variability in the cognitive effects of RTD between apparently similar groups of healthy subjects, and suggests the need for future RTD studies to control for a range of personality, family history, and genetic factors that may be associated with 5-HT function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The histological grading of cervical intraepithelial neoplasia (CIN) remains subjective, resulting in inter- and intra-observer variation and poor reproducibility in the grading of cervical lesions. This study has attempted to develop an objective grading system using automated machine vision. The architectural features of cervical squamous epithelium are quantitatively analysed using a combination of computerized digital image processing and Delaunay triangulation analysis; 230 images digitally captured from cases previously classified by a gynaecological pathologist included normal cervical squamous epithelium (n = 30), koilocytosis (n = 46), CIN 1 (n = 52), CIN 2 (n = 56), and CIN 3 (n=46). Intra- and inter-observer variation had kappa values of 0.502 and 0.415, respectively. A machine vision system was developed in KS400 macro programming language to segment and mark the centres of all nuclei within the epithelium. By object-oriented analysis of image components, the positional information of nuclei was used to construct a Delaunay triangulation mesh. Each mesh was analysed to compute triangle dimensions including the mean triangle area, the mean triangle edge length, and the number of triangles per unit area, giving an individual quantitative profile of measurements for each case. Discriminant analysis of the geometric data revealed the significant discriminatory variables from which a classification score was derived. The scoring system distinguished between normal and CIN 3 in 98.7% of cases and between koilocytosis and CIN 1 in 76.5% of cases, but only 62.3% of the CIN cases were classified into the correct group, with the CIN 2 group showing the highest rate of misclassification. Graphical plots of triangulation data demonstrated the continuum of morphological change from normal squamous epithelium to the highest grade of CIN, with overlapping of the groups originally defined by the pathologists. This study shows that automated location of nuclei in cervical biopsies using computerized image analysis is possible. Analysis of positional information enables quantitative evaluation of architectural features in CIN using Delaunay triangulation meshes, which is effective in the objective classification of CIN. This demonstrates the future potential of automated machine vision systems in diagnostic histopathology. Copyright (C) 2000 John Wiley and Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract BACKGROUND: Each year 40,000 men have a vasectomy in the UK whilst another 2400 request a reversal to begin a second family. Sperm can now be obtained by testicular biopsy and subsequently used in assisted conception with intracytoplasmic sperm injection (ICSI). The study aims were to compare sperm yields of men post-vasectomy or with obstructive azoospermia (OA) of unknown aetiology with fertile men and to assess any alteration in the clinical pregnancy rates after ICSI. METHODS: Testicular tissue was obtained by Trucut needle from men who had undergone a vasectomy >5yrs previously, had OA from other causes and from fertile men during vasectomy. Seminiferous tubules were milked to measure sperm yields. Numbers of Sertoli cells, spermatids and thickness of the seminiferous tubule walls were assessed using quantitative computerized analysis. RESULTS and CONCLUSIONS: Sperm yields/g testis were significantly decreased in men post-vasectomy and in men with OA, relative to fertile men. Significant reductions were also observed in early (40%) and mature (29%) spermatid numbers and an increase of 31% was seen in the seminiferous tubule wall (basal membrane and collagen thickness) of vasectomised men compared to fertile men. Clinical pregnancy rates in couples who had had a vasectomy were also significantly reduced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular disease (CVD) occurs more frequently in individuals with a family history of premature CVD. Within families the demographics of CVD are poorly described. DESIGN: We examined the risk estimation based on the Systematic Coronary Risk Evaluation (SCORE) system and the Joint British Guidelines (JBG) for older unaffected siblings of patients with premature CVD (onset ≤55 years for men and ≤60 years for women). METHODS: Between August 1999 and November 2003 laboratory and demographic details were collected on probands with early-onset CVD and their older unaffected siblings. Siblings were screened for clinically overt CVD by a standard questionnaire and 12-lead electrocardiogram (ECG). RESULTS: A total of 790 siblings was identified and full demographic details were available for 645. The following siblings were excluded: 41 with known diabetes mellitus; seven with random plasma glucose of 11.1 mmol/l or greater; and eight with ischaemic ECG. Data were analysed for 589 siblings from 405 families. The mean age was 55.0 years, 43.1% were men and 28.7% were smokers. The mean total serum cholesterol was 5.8 mmol/l and hypertension was present in 49.4%. Using the SCORE system, when projected to age 60 years, 181 men (71.3%) and 67 women (20.0%) would be eligible for risk factor modification. Using JBG with a 10-year risk of 20% or greater, 42 men (16.5%) and four women (1.2%) would be targeted. CONCLUSIONS: Large numbers of these asymptomatic individuals meet both European and British guidelines for the primary prevention of CVD and should be targeted for risk factor modification. The prevalence of individuals defined as eligible for treatment is much higher when using the SCORE system. © 2007 European Society of Cardiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cells subjected to various forms of stress have been shown to induce bystander responses in nontargeted cells, thus extending the stress response to a larger population. However, the mechanism(s) of bystander responses remains to be clearly identified, particularly for photodynamic stress. Oxidative stress and cell viability were studied on the spatial and temporal levels after photodynamic targeting of a subpopulation of EMT6 murine mammary cancer cells in a multiwell plate by computerized time-lapse fluorescence microscopy. In the targeted population a dose-dependent loss of cell viability was observed in accordance with increased oxidative stress. This was accompanied by increased oxidative stress in bystander populations but on different time scales, reaching a maximum more rapidly in targeted cells. Treatment with extracellular catalase, or the NADPH oxidase inhibitor diphenyleneiodinium, decreased production of reactive oxygen species (ROS) in both populations. These effects are ascribed to photodynamic activation of NADPH-oxidase in the targeted cells, resulting in a rapid burst of ROS formation with hydrogen peroxide acting as the signaling molecule responsible for initiation of these photodynamic bystander responses. The consequences of increased oxidative stress in bystander cells should be considered in the overall framework of photodynamic stress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The apolipoprotein (APOE) epsilon4 allele is a genetic risk factor for the development of Alzheimer's disease (AD). It has also been associated with vascular dementia (VaD) in some but not all studies. Previous studies have examined the role of APOE in predicting performance on cognitive tests in both demented and non-demented populations. In cognitively intact individuals, statistically significant group differences between APOE epsilon4 carriers and non-carriers have been demonstrated for several cognitive domains. In AD studies of the impact of APOE epsilon4 on cognition have been conflicting while no previous study has assessed cognition and impact of APOE epsilon4 in VaD. In this study we investigated the impact of APOE epsilon4 on performance in neuropsychological tests including information processing speed in patients with mild-moderate AD and VaD. We incorporated both computerized and pen and paper tests to ensure a sensitive method of assessing cognition. 109 patients participated in the study (VaD=41, AD=68). Neurocognitive performance of 44 epsilon4 present AD patients was compared to 24 epsilon4absent patients and performance of 23 epsilon4 present VaD patients was compared to 18 epsilon4 absent patients. There was evidence that APOE epsilon4 conferred a risk of poorer cognitive functioning in both patient groups. In the AD group presence of epsilon4 conferred a negative impact on some measures of speed of information processing and immediate recall while in the VaD group epsilon4 present patients had evidence of poorer accuracy on tasks such as choice reaction time and spatial working memory. In AD and VaD groups epsilon4 present patients showed impairment in selective attention. These findings provide further support of the negative impact of the epsilon4 allele in cognition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To evaluate the role of novel biomarkers in early detection of acute myocardial infarction (MI) in patients admitted with acute chest pain.
Methods and results: A prospective study of 664 patients presenting to two coronary care units with chest pain was conducted over 3 years from 2003. Patients were assessed on admission: clinical characteristics, ECG (electrocardiogram), renal function, cardiac troponin T (cTnT), heart fatty acid binding protein (H-FABP), glycogen phosphorylase-BB, NT-pro-brain natriuretic peptide, D-dimer, hsCRP (high sensitivity C-reactive protein), myeloperoxidase, matrix metalloproteinase-9, pregnancy associated plasma protein-A, soluble CD40 ligand. A =12 h cTnT sample was also obtained. MI was defined as cTnT = 0.03 µg/L. In patients presenting <4 h of symptom onset, sensitivity of H-FABP for MI was significantly higher than admission cTnT (73 vs. 55%; P = 0.043). Specificity of H-FABP was 71%. None of the other biomarkers challenged cTnT. Combined use of H-FABP and cTnT (either one elevated initially) significantly improved the sensitivities of H-FABP or cTnT (85%; P = 0.004). This combined approach also improved the negative predictive value, negative likelihood ratio, and the risk ratio.
Conclusion: Assessment of H-FABP within the first 4 h of symptoms is superior to cTnT for detection of MI, and is a useful additional biomarker for patients with acute chest pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the relationship between a chronometric estimate of automaticity for the spelling of French words (Automaticity) and performance on four tests of French language attainment among a sample of Year 11 students of French as a foreign language. Fifty participants each completed a computerized test of French spelling and attainment tests in four aspects of French language learning: reading comprehension, writing fluency, oral fluency, and aural comprehension. Correlations were significant between Automaticity and performance on all four tests of French language attainment as well as on overall attainment.