87 resultados para body-on-a chip
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
A microfluidic glass chip system incorporating a quartz crystal microbalance (QCM) to measure the square root of the viscosity-density product of room temperature ionic liquids (RTILs) is presented. The QCM covers a central recess on a glass chip, with a seal formed by tightly clamping from above outside the sensing region. The change in resonant frequency of the QCM allows for the determination of the square root viscosity-density product of RTILs to a limit of similar to 10 kg m(-2) s(-0.5). This method has reduced the sample size needed for characterization from 1.5 ml to only 30 mu l and allows the measurement to be made in an enclosed system.
Resumo:
A new domain-specific, reconfigurable system-on-a-chip (SoC) architecture is proposed for video motion estimation. This has been designed to cover most of the common block-based video coding standards, including MPEG-2, MPEG-4, H.264, WMV-9 and AVS. The architecture exhibits simple control, high throughput and relatively low hardware cost when compared with existing circuits. It can also easily handle flexible search ranges without any increase in silicon area and can be configured prior to the start of the motion estimation process for a specific standard. The computational rates achieved make the circuit suitable for high-end video processing applications, such as HDTV. Silicon design studies indicate that circuits based on this approach incur only a relatively small penalty in terms of power dissipation and silicon area when compared with implementations for specific standards. Indeed, the cost/performance achieved exceeds that of existing but specific solutions and greatly exceeds that of general purpose field programmable gate array (FPGA) designs.
Resumo:
The design of a System-on-a-Chip (SoC) demonstrator for a baseline JPEG encoder core is presented. This combines a highly optimized Discrete Cosine Transform (DCT) and quantization unit with an entropy coder which has been realized using off-the-shelf synthesizable IP cores (Run-length coder, Huffman coder and data packer). When synthesized in a 0.35 µm CMOS process, the core can operate at speeds up to 100 MHz and contains 50 k gates plus 11.5 kbits of RAM. This is approximately 20% less than similar JPEG encoder designs reported in literature. When targeted at FPGA the core can operate up to 30 MHz and is capable of compressing 9-bit full-frame color input data at NTSC or PAL rates.
Resumo:
In this study, we describe a simple and efficient method for on-chip storage of reagents for point-of-care (POC) diagnostics. The method is based on gelification of all reagents required for on-chip PCR-based diagnostics as a ready-to-use product. The result reported here is a key step towards the development of a ready and easy to use fully integrated Lab-on-a-chip (LOC) system for fast, cost-effective and efficient POC diagnostics analysis.
Resumo:
This paper describes the creation of a germanium on sapphire platform, via wafer bonding technology, for system-on-a-chip applications. Similar thermal coefficients of expansion between germanium (5.8 x 10-6 K-1) and sapphire (5 x 10-6 K-1) make the bonding of germanium to sapphire a reality. Germanium directly bonded to sapphire results in microvoid generation during post bond annealing. Inclusion of an interface layer such as silicon dioxide layer by plasma enhanced chemical vapour deposition, prior to bonding, results in a microvoid free bond interface after annealing. Grinding and polishing of the subsequent germanium layer has been achieved leaving a thick germanium on sapphire (GeOS) substrate. Submicron GeOS layers have also been achieved with hydrogen/helium co-implantation and layer transfer. Circular geometry transistors exhibiting a field effect mobility of 890 cm2/V s have been fabricated onto the thick germanium on sapphire layer.
Resumo:
This paper explores the potential of germanium on sapphire (GeOS) wafers as a universal substrate for System on a Chip (SOC), mm wave integrated circuits (MMICs) and optical imagers. Ge has a lattice constant close to that of GaAs enabling epitaxial growth. Ge, GaAs and sapphire have relatively close temperature coefficients of expansion (TCE), enabling them to be combined without stress problems. Sapphire is transparent over the range 0.17 to 5.5 µm and has a very low loss tangent (a) for frequencies up to 72 GHz. Ge bonding to sapphire substrates has been investigated with regard to micro-voids and electrical quality of the Ge back interface. The advantages of a sapphire substrate for integrated inductors, coplanar waveguides and crosstalk suppression are also highlighted. MOS transistors have been fabricated on GeOS substrates, produced by the Smart-cut process, to illustrate the compatibility of the substrate with device processing. © 2008 World Scientific Publishing Company.
Resumo:
Surface plasmon resonance (SPR) based biosensor technology has been widely used in life science research for many applications. While the advantages of speed, ruggedness, versatility, sensitivity and reproducibility are often quoted, many researchers have experienced severe problem of non-specific binding (NSB) to chip surfaces when performing analysis of biological samples Such as bovine serum. Using the direct measurement of the bovine protein leptin, present in bovine serum samples as a model, a unique buffering system has been developed and optimised which was able to significantly reduce the non-specific interactions of bovine serum components with the carboxymethyl dextran chip (CM5) surface on a Biacore SPR The developed NSB buffering system comprised of HBS-EP buffer, containing 0.5 M NaCl, 0.005% CM-dextran pH 9.0. An average NSB reduction (n = 20) of 85.9% and 87.3% was found on an unmodified CM5 surface and a CM5 with bovine leptin immobilised on the chip surface, respectively. A reduction in NSB of up to 94% was observed on both surfaces. The concentration of the constitutive components and pH of the buffer were crucial in achieving this outcome. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The emergence of programmable logic devices as processing platforms for digital signal processing applications poses challenges concerning rapid implementation and high level optimization of algorithms on these platforms. This paper describes Abhainn, a rapid implementation methodology and toolsuite for translating an algorithmic expression of the system to a working implementation on a heterogeneous multiprocessor/field programmable gate array platform, or a standalone system on programmable chip solution. Two particular focuses for Abhainn are the automated but configurable realisation of inter-processor communuication fabrics, and the establishment of novel dedicated hardware component design methodologies allowing algorithm level transformation for system optimization. This paper outlines the approaches employed in both these particular instances.
Resumo:
Herein, we present the use of a single gold nanorod sensor for detection of diseases on an antibody-functionalized surface, based on antibody–antigen interaction and the localized surface plasmon resonance (LSPR) ?max shifts of the resonant Rayleigh light scattering spectra. By replacing the cetyltrimethylammonium bromide (CTAB), a tightly packed self-assembled monolayer of HS(CH2)11(OCH2CH2)6OCH2COOH(OEG6) has been successfully formed on the gold nanorod surface prior to the LSPR sensing, leading to the successful fabrication of individual gold nanorod immunosensors. Using prostate specific antigen (PSA) as a protein biomarker, the lowest concentration experimentally detected was as low as 111 aM, corresponding to a 2.79 nm LSPR ?max shift. These results indicate that the detection platform is very sensitive and outperforms detection limits of commercial tests for PSA so far. Correlatively, its detection limit can be equally compared to the assays based on DNA biobarcodes. This study shows that a gold nanorod has been used as a single nanobiosensor to detect antigens for the first time; and the detection method based on the resonant Rayleigh scattering spectrum of individual gold nanorods enables a simple, label-free detection with ultrahigh sensitivity.
Resumo:
Reagent pre-storage in a microfluidic chip can enhance operator convenience, simplify the system design, reduce the cost of storage and shipment, and avoid the risk of cross-contamination. Although dry reagents have long been used in lateral flow immunoassays, they have rarely been used for nucleic acid-based point-of-care (POC) assays due to the lack of reliable techniques to dehydrate and store fragile molecules involved in the reaction. In this study, we describe a simple and efficient method for prolonged on-chip storage of PCR reagents. The method is based on gelification of all reagents required for PCR as a ready-to-use product. The approach was successfully implemented in a lab-on-a-foil system, and the gelification process was automated for mass production. Integration of reagents on-chip by gelification greatly facilitated the development of easy-to-use lab-on-a-chip (LOC) devices for fast and cost-effective POC analysis.
Resumo:
More than 200 known diseases are transmitted via foods or food products. In the United States, food-borne diseases are responsible for 76 million cases of illness, 32,500 cases of hospitalisation and 5000 cases of death yearly. The ongoing increase in worldwide trade in livestock, food, and food products in combination with increase in human mobility (business- and leisure travel, emigration etc.) will increase the risk of emergence and spreading of such pathogens. There is therefore an urgent need for development of rapid, efficient and reliable methods for detection and identification of such pathogens.
Microchipfabrication has had a major impact on electronics and is expected to have an equally pronounced effect on life sciences. By combining micro-fluidics with micromechanics, micro-optics, and microelectronics, systems can be realized to perform complete chemical or biochemical analyses. These socalled ’Lab-on-a-Chip’ will completely change the face of laboratories in the future where smaller, fully automated devices will be able to perform assays faster, more accurately, and at a lower cost than equipment of today. A general introduction of food safety and applied micro-nanotechnology in life sciences will be given. In addition, examples of DNA micro arrays, micro fabricated integrated PCR chips and total integrated lab-on-achip systems from different National and EU research projects being carried out at the Laboratory of Applied Micro- Nanotechnology (LAMINATE) group at the National Veterinary Institute (DTU-Vet) Technical University of Denmark and the BioLabchip group at the Department of Micro and Nanotechnology (DTU-Nanotech), Technical University of Denmark (DTU), Ikerlan-IK4 (Spain) and other 16 partners from different European countries will be presented.
Resumo:
Features of chip formation can inform the mechanism of a machining process. In this paper, a series of orthogonal cutting experiments were carried out on unidirectional carbon fiber reinforced polymer (UD-CFRP) under cutting speed of 0.5 m/min. The specially designed orthogonal cutting tools and high-speed camera were used in this paper. Two main factors are found to influence the chip morphology, namely the depth of cut (DOC) and the fiber orientation (angle 휃), and the latter of which plays a more dominant role. Based on the investigation of chip formation, a new approach is proposed for predicting fracture toughness of the newly machined surface and the total energy consumption during CFRP orthogonal cutting is introduced as a function of the surface energy of machined surface, the energy consumed to overcome friction, and the energy for chip fracture. The results show that the proportion of energy spent on tool-chip friction is the greatest, and the proportions of energy spent on creating new surface decrease with the increasing of fiber angle.