Developing a desirable framework for handling inconsistencies in software requirements specifications is a challenging problem. It has been widely recognized that the relative priority of requirements can help developers to make some necessary trade-off decisions for resolving con- flicts. However, for most distributed development such as viewpoints-based approaches, different stakeholders may assign different levels of priority to the same shared requirements statement from their own perspectives. The disagreement in the local levels of priority assigned to the same shared requirements statement often puts developers into a dilemma during the inconsistency handling process. The main contribution of this paper is to present a prioritized merging-based framework for handling inconsistency in distributed software requirements specifications. Given a set of distributed inconsistent requirements collections with the local prioritization, we first construct a requirements specification with a prioritization from an overall perspective. We provide two approaches to constructing a requirements specification with the global prioritization, including a merging-based construction and a priority vector-based construction. Following this, we derive proposals for handling inconsistencies from the globally prioritized requirements specification in terms of prioritized merging. Moreover, from the overall perspective, these proposals may be viewed as the most appropriate to modifying the given inconsistent requirements specification in the sense of the ordering relation over all the consistent subsets of the requirements specification. Finally, we consider applying negotiation-based techniques to viewpoints so as to identify an acceptable common proposal from these proposals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract
BACKGROUND:
Glaucoma is a leading cause of blindness. Early detection is advocated but there is insufficient evidence from randomized controlled trials (RCTs) to inform health policy on population screening. Primarily, there is no agreed screening intervention. For a screening programme, agreement is required on the screening tests to be used, either individually or in combination, the person to deliver the test and the location where testing should take place. This study aimed to use ophthalmologists (who were experienced glaucoma subspecialists), optometrists, ophthalmic nurses and patients to develop a reduced set of potential screening tests and testing arrangements that could then be explored in depth in a further study of their feasibility for evaluation in a glaucoma screening RCT.
METHODS:
A two-round Delphi survey involving 38 participants was conducted. Materials were developed from a prior evidence synthesis. For round one, after some initial priming questions in four domains, specialists were asked to nominate three screening interventions, the intervention being a combination of the four domains; target population, (age and higher risk groups), site, screening test and test operator (provider). More than 250 screening interventions were identified. For round two, responses were condensed into 72 interventions and each was rated by participants on a 0-10 scale in terms of feasibility.
RESULTS:
Using a cut-off of a median rating of feasibility of =5.5 as evidence of agreement of intervention feasibility, six interventions were identified from round 2. These were initiating screening at age 50, with a combination of two or three screening tests (varying combinations of tonometry/measures of visual function/optic nerve damage) organized in a community setting with an ophthalmic trained technical assistant delivering the tests. An alternative intervention was a 'glaucoma risk score' ascertained by questionnaire. The advisory panel recommended that further exploration of the feasibility of screening higher risk populations and detailed specification of the screening tests was required.
CONCLUSIONS:
With systematic use of expert opinions, a shortlist of potential screening interventions was identified. Views of users, service providers and cost-effectiveness modeling are now required to identify a feasible intervention to evaluate in a future glaucoma screening trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Often the modification and enhancement of large scientific software systems are severely hampered because many components of the system are written in an implementation dependent fashion, they are inadequately documented, and their functionalities are not precisely known. In this paper we consider how mathematics may be employed to alleviate some of these problems. In particular, we illustrate how the formal specification notation VDM-SL is being used to specify precisely abstract data types for use in the development of scientific software.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design cycle for complex special-purpose computing systems is extremely costly and time-consuming. It involves a multiparametric design space exploration for optimization, followed by design verification. Designers of special purpose VLSI implementations often need to explore parameters, such as optimal bitwidth and data representation, through time-consuming Monte Carlo simulations. A prominent example of this simulation-based exploration process is the design of decoders for error correcting systems, such as the Low-Density Parity-Check (LDPC) codes adopted by modern communication standards, which involves thousands of Monte Carlo runs for each design point. Currently, high-performance computing offers a wide set of acceleration options that range from multicore CPUs to Graphics Processing Units (GPUs) and Field Programmable Gate Arrays (FPGAs). The exploitation of diverse target architectures is typically associated with developing multiple code versions, often using distinct programming paradigms. In this context, we evaluate the concept of retargeting a single OpenCL program to multiple platforms, thereby significantly reducing design time. A single OpenCL-based parallel kernel is used without modifications or code tuning on multicore CPUs, GPUs, and FPGAs. We use SOpenCL (Silicon to OpenCL), a tool that automatically converts OpenCL kernels to RTL in order to introduce FPGAs as a potential platform to efficiently execute simulations coded in OpenCL. We use LDPC decoding simulations as a case study. Experimental results were obtained by testing a variety of regular and irregular LDPC codes that range from short/medium (e.g., 8,000 bit) to long length (e.g., 64,800 bit) DVB-S2 codes. We observe that, depending on the design parameters to be simulated, on the dimension and phase of the design, the GPU or FPGA may suit different purposes more conveniently, thus providing different acceleration factors over conventional multicore CPUs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With interest in microneedles as a novel drug transdermal delivery system increasing rapidly since the late 1990s (Margetts and Sawyer Contin Educ Anaesthesia Crit Care Pain. 7(5):171-76, 2007), a diverse range of microneedle systems have been fabricated with varying designs and dimensions. However, there are still very few commercially available microneedle products. One major issue regarding microneedle manufacture on an industrial scale is the lack of specific quality standards for this novel dosage form in the context of Good Manufacturing Practice (GMP). A range of mechanical characterisation tests and microneedle insertion analysis techniques are used by researchers working on microneedle systems to assess the safety and performance profiles of their various designs. The lack of standardised tests and equipment used to demonstrate microneedle mechanical properties and insertion capability makes it difficult to directly compare the in use performance of candidate systems. This review highlights the mechanical tests and insertion analytical techniques used by various groups to characterise microneedles. This in turn exposes the urgent need for consistency across the range of microneedle systems in order to promote innovation and the successful commercialisation of microneedle products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of high-quality quarried crushed rock aggregates is generally required to comply with current specifications for unbound granular materials (UGMs) in pavements. The source of these high-quality materials can be a long distance from the site, resulting in high transportation costs. The use of more local sources of marginal materials or the use of secondary aggregates is not allowed if they do not fully comply with existing specifications. These materials can, however, be assessed for their suitability for use in a pavement by considering performance criteria such as resistance to permanent deformation and degradation instead of relying on compliance with inflexible specifications. The final thickness of the asphalt cover and the pavement depth are governed by conventional pavement design methods, which consider the number of vehicle passes, subgrade strength, and some material property, commonly the California bearing ratio or resilient modulus. A pavement design method that includes as a design criterion an assessment of the resistance to deformation of a UGM in a pavement structure at a particular stress state is proposed. The particular stress state at which the aggregate is to perform in an acceptable way is related to the in situ stress, that is, the stress that the aggregate is anticipated to experience at a particular depth in the pavement. Because the stresses are more severe closer to the pavement surface, the aggregates should be better able to resist these stresses the closer they are laid to the surface in the pavement. This method was applied to two Northern Ireland aggregates of different quality (NI Good and NI Poor). The results showed that the NI Poor aggregate performed at an acceptable level with respect to permanent deformation, provided that a minimum of 70 mm of asphalt cover was provided. It was predicted that the NI Good material would require 60 mm of asphalt cover.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Architectures and methods for the rapid design of silicon cores for implementing discrete wavelet transforms over a wide range of specifications are described. These architectures are efficient, modular, scalable, and cover orthonormal and biorthogonal wavelet transform families. They offer efficient hardware utilization by exploiting a number of core wavelet filter properties and allow the creation of silicon designs that are highly parameterized, including in terms of wavelet type and wordlengths. Control circuitry is embedded within these systems allowing them to be cascaded for any desired level of decomposition without any interface glue logic. The time to produce chip designs for a specific wavelet application is typically less than a day and these are comparable in area and performance to handcrafted designs. They are also portable across a wide range of silicon foundries and suitable for field programmable gate array and programmable logic data implementation. The approach described has also been extended to wavelet packet transforms.