32 resultados para Source to sinks

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The characteristics of an extreme-ultraviolet (XUV) continuum light source and its application to a dual-laser plasma (DLP) photoabsorption experiment are described. The continuum emitting plasma was formed by focusing a 7 ps, 248 nm, 15 mJ laser pulse onto a number of selected targets known to be good XUV continuum emitters (Sm, W, Au and Pb), while the second absorbing plasma was produced by a 15 ns, 1064 nm, 300 mi pulse. The duration of the continuum emission for these plasmas has a mean value of similar to 150 ps, but depends on both the target material and the picosecond laser pulse energy. Using this picosecond DLP set-up we have been able to measure the photoabsorption spectrum of an actinide ion (thorium) for the first time.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: Several surveillance definitions of influenza-like illness (ILI) have been proposed, based on the presence of symptoms. Symptom data can be obtained from patients, medical records, or both. Past research has found that agreements between health record data and self-report are variable depending on the specific symptom. Therefore, we aimed to explore the implications of using data on influenza symptoms extracted from medical records, similar data collected prospectively from outpatients, and the combined data from both sources as predictors of laboratory-confirmed influenza. Methods: Using data from the Hutterite Influenza Prevention Study, we calculated: 1) the sensitivity, specificity and predictive values of individual symptoms within surveillance definitions; 2) how frequently surveillance definitions correlated to laboratory-confirmed influenza; and 3) the predictive value of surveillance definitions. Results: Of the 176 participants with reports from participants and medical records, 142 (81%) were tested for influenza and 37 (26%) were PCR positive for influenza. Fever (alone) and fever combined with cough and/or sore throat were highly correlated with being PCR positive for influenza for all data sources. ILI surveillance definitions, based on symptom data from medical records only or from both medical records and self-report, were better predictors of laboratory-confirmed influenza with higher odds ratios and positive predictive values. Discussion: The choice of data source to determine ILI will depend on the patient population, outcome of interest, availability of data source, and use for clinical decision making, research, or surveillance. © Canadian Public Health Association, 2012.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The properties of blood and the relative ease of access to which it can be retrieved make it an ideal source to gauge different aspects of homeostasis within an individual, form an accurate diagnosis, and formulate an appropriate treatment regime. Tests used to determine blood parameters such as the erythrocyte sedimentation rate, hemoglobin concentration, hematocrit, bleeding and clotting times, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, mean cell volume, and determination of blood groups are routinely used clinically, and deviations outside the normal range can indicate a range of conditions such as anemia, pregnancy, dehydration, overhydration, infectious disease, cancer, thyroid disease, and autoimmune conditions, to mention a few. As these tests can be performed relatively inexpensively and do not require high levels of technical expertise, they are ideally suited for use in the teaching laboratory, enabling undergraduate students to link theory to practice. The practicals described here permit students to examine their own blood and that of their peers and compare these with clinically accepted normal ranges. At the end of the practicals, students are required to answer a number of questions about their findings and to link abnormal values to possible pathological conditions by answering a series of questions based on their findings.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Network security monitoring remains a challenge. As global networks scale up, in terms of traffic, volume and speed, effective attribution of cyber attacks is increasingly difficult. The problem is compounded by a combination of other factors, including the architecture of the Internet, multi-stage attacks and increasing volumes of nonproductive traffic. This paper proposes to shift the focus of security monitoring from the source to the target. Simply put, resources devoted to detection and attribution should be redeployed to efficiently monitor for targeting and prevention of attacks. The effort of detection should aim to determine whether a node is under attack, and if so, effectively prevent the attack. This paper contributes by systematically reviewing the structural, operational and legal reasons underlying this argument, and presents empirical evidence to support a shift away from attribution to favour of a target-centric monitoring approach. A carefully deployed set of experiments are presented and a detailed analysis of the results is achieved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: Positron emission tomography (PET)/CT scans can improve target definition in radiotherapy for non-small cell lung cancer (NSCLC). As staging PET/CT scans are increasingly available, we evaluated different methods for co-registration of staging PET/CT data to radiotherapy simulation (RTP) scans.

Methods: 10 patients underwent staging PET/CT followed by RTP PET/CT. On both scans, gross tumour volumes (GTVs) were delineated using CT (GTVCT) and PET display settings. Four PET-based contours (manual delineation, two threshold methods and a source-to-background ratio method) were delineated. The CT component of the staging scan was co-registered using both rigid and deformable techniques to the CT component of RTP PET/CT. Subsequently rigid registration and deformation warps were used to transfer PET and CT contours from the staging scan to the RTP scan. Dice’s similarity coefficient (DSC) was used to assess the registration accuracy of staging-based GTVs following both registration methods with the GTVs delineated on the RTP PET/CT scan.

Results: When the GTVCT delineated on the staging scan after both rigid registration and deformation was compared with the GTVCT on the RTP scan, a significant improvement in overlap (registration) using deformation was observed (mean DSC 0.66 for rigid registration and 0.82 for deformable registration, p50.008). A similar comparison for PET contours revealed no significant improvement in overlap with the use of deformable registration.

Conclusions: No consistent improvements in similarity measures were observed when deformable registration was used for transferring PET-based contours from a staging PET/CT. This suggests that currently the use of rigid registration remains the most appropriate method for RTP in NSCLC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Computational modelling is becoming ever more important for obtaining regulatory approval for new medical devices. An accepted approach is to infer performance in a population from an analysis conducted for an idealised or ‘average’ patient; we present here a method for predicting the performance of an orthopaedic implant when released into a population—effectively simulating a clinical trial. Specifically we hypothesise that an analysis based on a method for predicting the performance in a population will lead to different conclusions than an analysis based on an idealised or ‘average’ patient. To test this hypothesis we use a finite element model of an intramedullary implant in a bone whose size and remodelling activity is different for each individual in the population. We compare the performance of a low Young’s modulus implant (View the MathML source) to one with a higher Young’s modulus (200 GPa). Cyclic loading is applied and failure is assumed when the migration of the implant relative to the bone exceeds a threshold magnitude. The analysis for an idealised of ‘average’ patient predicts that the lower modulus device survives longer whereas the analysis simulating a clinical trial predicts no statistically-significant tendency (p=0.77) for the low modulus device to perform better. It is concluded that population-based simulations of implant performance–simulating a clinical trial–present a very valuable opportunity for more realistic computational pre-clinical testing of medical devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We compare the results of our JCMT spectral line survey of molecular gas towards ultracompact HII regions with the predictions of models of sulphur chemistry in hot cores. We investigate the range of evolutionary models that are consistent with the observed physical conditions and chemical abundances, and see to what extent it is possible to constrain core ages by comparing abundances with the predictions of chemical models. The observed abundance ratios vary little from source to source, suggesting that all the sources are at a similar evolutionary stage. The models are capable of predicting the observed abundances of H2S, SO, SO2, and CS. The models fail to predict the amount of OCS observed, suggesting that an alternative formation route is required. An initial H2S abundance from grain mantle evaporation of similar to 10(-7) is preferred.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The fate and cycling of two selected POPs is investigated for the North Sea system with an improved version of a fate and transport ocean model (FANTOM). The model uses atmospheric data from the EMEP MSC East POP model (Gusev et al., 2009), giving reasonable concentrations and seasonal distributions for the entire region, as opposed to the three observation stations that Ilyina et al. (2006) were limited to. Other model improvements include changes in the calculation of POP exchange between the water column and sediment.

We chose to simulate the fate of two POPs with very different properties, ?-HCH and PCB 153. Since the fate and cycling of POPs are strongly affected by hydrodynamic processes, a high resolution version of the Hamburg Shelf Ocean Model (HAMSOM) was developed and utilised. Simulations were made for the period 1996–2005. Both models were validated by comparing results with available data, which showed that the simulations were of very satisfactory quality.

Model results show that the North Sea is a net sink for ?-HCH and a net source to the atmosphere of PCB 153. Total masses of ?-HCH and PCB 153 in 2005 are reduced to 30% and 50%, respectively, of 1996 values.

Storms resuspending bottom sediments into the water column mobilise POPs into the atmosphere and have the potential to deliver substantial loads of these POPs into Europe.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the introduction of budget airlines and greater competitiveness amongst all airlines, air travel has now become an extremely popular form of travel, presenting its own unique set of risks from food poisoning. Foodborne illness associated with air travel is quite uncommon in the modern era. However, when it occurs, it may have serious implications for passengers and when crew are affected, has the potential to threaten safety. Quality, safe, in-flight catering relies on high standards of food preparation and storage; this applies at the airport kitchens (or at subcontractors' facilities), on the aircraft and in the transportation vehicles which carry the food from the ground source to the aircraft. This is especially challenging in certain countries. Several foodborne outbreaks have been recorded by the airline industry as a result of a number of different failures of these systems. These have provided an opportunity to learn from past mistakes and current practice has, therefore, reached such a standard so as to minimise risk of failures of this kind. This review examines: (i) the origin of food safety in modern commercial aviation; (ii) outbreaks which have occurred previously relating to aviation travel; (iii) the microbiological quality of food and water on board commercial aircraft; and (iv) how Hazard Analysis Critical Control Points may be employed to maintain food safety in aviation travel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hydrogen is expected to play an important role in future transportation as a promising alternative clean energy source to carbon-based fuels. One of the key challenges to commercialize hydrogen energy is to develop appropriate onboard hydrogen storage systems, capable of charging and discharging large quantities of hydrogen with fast enough kinetics to meet commercial requirements. Metal organic framework (MOF) is a new type of inorganic and organic hybrid nanoporous particulate materials. Its diverse networks can enhance hydrogen storage through tuning the structure and property of MOFs. The MOF materials so far developed adsorb hydrogen through weak dispersion interactions, which allow significant quantity of hydrogen to be stored at cryogenic temperatures with fast kinetics. Novel MOFs are being developed to strengthen the interactions between hydrogen and MOFs in order to store hydrogen under ambient conditions. This review surveys the development of such candidate materials, their performance and future research needs. (C) 2009 Chinese Society of Particuology and Institute of Process Engineering, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We consider the distribution of entanglement from a multimode optical driving source to a network of remote and independent optomechanical systems. By focusing on the tripartite case, we analyse the effects that the features of the optical input states have on the degree and sharing structure of the distributed, fully mechanical, entanglement. This study, which is conducted looking at the mechanical steady state, highlights the structure of the entanglement distributed among the nodes and determines the relative efficiency between bipartite and tripartite entanglement transfer. We discuss a few open points, some of which are directed towards the bypassing of such limitations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Do clinicians manage pregnancies conceived by assisted reproductive technologies (ART) differently from spontaneous pregnancies?

Clinicians decisions about prenatal testing during pregnancy depend, at least partially, on the method of conception.

Research thus far has shown that patients decisions regarding prenatal screening are different in ART pregnancies compared with spontaneous ones, such that ART pregnancies may be considered more valuable or precious than pregnancies conceived without treatment.

In this cross-sectional study, preformed during the year 2011, 163 obstetricians and gynecologists in Israel completed an anonymous online questionnaire.

Clinicians were randomly assigned to read one of two versions of a vignette describing the case of a pregnant woman. The two versions differed only with regard to the method of conception (ART; n 78 versus spontaneous; n 85). Clinicians were asked to provide their recommendations regarding amniocentesis.

The response rate among all clinicians invited to complete the questionnaire was 16.7. Of the 85 clinicians presented with the spontaneous pregnancy scenario, 37 (43.5) recommended amniocentesis. In contrast, of the 78 clinicians presented with the ART pregnancy scenario, only 15 (19.2) recommended the test. Clinicians were 3.2 (95 confidence interval [CI]: 1.66.6) times more likely to recommend amniocentesis for a spontaneous pregnancy than for an ART pregnancy.

The study is limited by a low response rate, the relatively small sample and the hypothetical nature of the decision, as clinician recommendations may have differed in an actual clinical setting.

Our findings show that fertility history and use of ART may affect clinicians recommendations regarding amniocentesis following receipt of screening test results. This raises the question of how subjective factors influence clinicians decisions regarding other aspects of pregnancy management.

There was no funding source to this study. The authors declare no conflicts of interest.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aims: High local control rates are achieved in stage I lung cancer using stereotactic ablative radiotherapy. Target delineation is commonly based on four-dimensional computed tomography (CT) scans. Target volumes defined by positron emission tomography/computed tomography (PET/CT) are compared with those defined by four-dimensional CT and conventional ('three-dimensional') F-fluorodeoxyglucose (F-FDG) PET/CT. Materials and methods: For 16 stage I non-small cell lung cancer tumours, six approaches for deriving PET target volumes were evaluated: manual contouring, standardised uptake value (SUV) absolute threshold of 2.5, 35% of maximum SUV (35%SUV), 41% of SUV (41%SUV) and two different source to background ratio techniques (SBR-1 and SBR-2). PET-derived target volumes were compared with the internal target volume (ITV) from the modified maximum intensity projection (MIP ITV). Volumetric and positional correlation was assessed using the Dice similarity coefficient (DSC). Results: PET-based target volumes did not correspond to four-dimensional CT-based target volumes. The mean DSC relative to MIP ITV were: PET manual = 0.64, SUV2.5 = 0.64, 35%SUV = 0.63, 41%SUV = 0.57. SBR-1 = 0.52, SBR-2 = 0.49. PET-based target volumes were smaller than corresponding MIP ITVs. Conclusions: Conventional three-dimensional F-FDG PET-derived target volumes for lung stereotactic ablative radiotherapy did not correspond well with those derived from four-dimensional CT, including those in routine clinical use (MIP ITV). Caution is required in using three-dimensional PET for motion encompassing target volume delineation. © 2012 The Royal College of Radiologists.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIMS: High local control rates are achieved in stage I lung cancer using
stereotactic ablative radiotherapy. Target delineation is commonly based on
four-dimensional computed tomography (CT) scans. Target volumes defined by
positron emission tomography/computed tomography (PET/CT) are compared with those defined by four-dimensional CT and conventional ('three-dimensional')
(18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT.

MATERIALS AND METHODS: For 16 stage I non-small cell lung cancer tumours, six
approaches for deriving PET target volumes were evaluated: manual contouring,
standardised uptake value (SUV) absolute threshold of 2.5, 35% of maximum SUV
(35%SUV(MAX)), 41% of SUV(MAX) (41%SUV(MAX)) and two different source to
background ratio techniques (SBR-1 and SBR-2). PET-derived target volumes were compared with the internal target volume (ITV) from the modified maximum
intensity projection (MIP(MOD) ITV). Volumetric and positional correlation was
assessed using the Dice similarity coefficient (DSC).

RESULTS: PET-based target volumes did not correspond to four-dimensional CT-based target volumes. The mean DSC relative to MIP(MOD) ITV were: PET manual = 0.64, SUV2.5 = 0.64, 35%SUV(MAX) = 0.63, 41%SUV(MAX) = 0.57. SBR-1 = 0.52, SBR-2 =0.49. PET-based target volumes were smaller than corresponding MIP ITVs.

CONCLUSIONS: Conventional three-dimensional (18)F-FDG PET-derived target volumes for lung stereotactic ablative radiotherapy did not correspond well with those derived from four-dimensional CT, including those in routine clinical use
(MIP(MOD) ITV). Caution is required in using three-dimensional PET for motion
encompassing target volume delineation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The proliferation of mobile devices in society accessing data via the ‘cloud’ is imposing a dramatic increase in the amount of information to be stored on hard disk drives (HDD) used in servers. Forecasts are that areal densities will need to increase by as much as 35% compound per annum and by 2020 cloud storage capacity will be around 7 zettabytes corresponding to areal densities of 2 Tb/in2. This requires increased performance from the magnetic pole of the electromagnetic writer in the read/write head in the HDD. Current state-of-art writing is undertaken by morphologically complex magnetic pole of sub 100 nm dimensions, in an environment of engineered magnetic shields and it needs to deliver strong directional magnetic field to areas on the recording media around 50 nm x 13 nm. This points to the need for a method to perform direct quantitative measurements of the magnetic field generated by the write pole at the nanometer scale. Here we report on the complete in situ quantitative mapping of the magnetic field generated by a functioning write pole in operation using electron holography. Opportunistically, it points the way towards a new nanoscale magnetic field source to further develop in situ Transmission Electron Microscopy.