9 resultados para Screening-program
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
Familial hypercholesterolemia (FH) is a common single gene disorder, which predisposes to coronary artery disease. In a previous study, we have shown that in patients with definite FH around 20% had no identifiable gene defect after screening the entire exon coding area of the low density lipoprotein receptor (LDLR) and testing for the common Apolipoprotein B (ApoB) R3500Q mutation. In this study, we have extended the screen to additional families and have included the non-coding intron splice regions of the gene. In families with definite FH (tendon xanthoma present, n = 68) the improved genetic screening protocol increased the detection rate of mutations to 87%. This high detection rate greatly enhances the potential value of this test as part of a clinical screening program for FH. In contrast, the use of a limited screen in patients with possible FH (n = 130) resulted in a detection rate of 26%, but this is still of significant benefit in diagnosis of this genetic condition. We have also shown that 14% of LDLR defects are due to splice site mutations and that the most frequent splice mutation in our series (c.1845 + 11 c > g) is expressed at the RNA level. In addition, DNA samples from the patients in whom no LDLR or ApoB gene mutations were found, were sequenced for the NARC-1 gene. No mutations were identified which suggests that the role of NARC-1 in causing FH is minor. In a small proportion of families (
Resumo:
The aim of this study was to develop a mutation screening protocol for familial hypercholesterolaemia (FH) patients and to assess genotype/phenotype effects in terms of pre-treatment lipid profiles and presentation of tendon xanthomata (TX). A total of 158 families with clinical definitions of possible (120) or definite (38) FH were studied using a tiered screening protocol. Mutations were identified in 52 families, 44 families showing 23 different LDLR gene defects and eight families showing the common Apo B100 gene defect R3500Q. LDLR defects were detected in various regions of the gene with 56% in the LDL binding domain (exons 2-6) and 37% in the EGF precursor homology domain (exons 7-14). The most common mutations were D461N(7), C210X(5), 932delA(5), and C163Y(4). Frameshift mutations accounted for 20% with nonsense 13%, mis-sense 35%, splice 3%, Apo B 13% and 2% large deletion, 13% of clinically definite FH remained undefined. In conclusion, DNA based diagnosis is possible in 79% (30/38) of clinically definite FH families and of the 120 possible FH families at the start of the screening program, 18% (22/120) now have defined mutations. Overall 60 families from the original 158 meet the clinical and/or genetic criteria for definite FH. Tendon xanthomata were present in only 58% (30/52) of genetically defined FH families, thus limiting its use as a strict diagnostic criteria. Families with low density lipoprotein receptor (LDLR) defects present with higher total and LDL cholesterol levels and a higher incidence of TX than do those with the common Apo B variant, and frameshift mutations appear to have the most severe presentation. Copyright (C) 1999 Elsevier Science Ireland Ltd.
Resumo:
IMPORTANCE: Prevention strategies for heart failure are needed.
OBJECTIVE: To determine the efficacy of a screening program using brain-type natriuretic peptide (BNP) and collaborative care in an at-risk population in reducing newly diagnosed heart failure and prevalence of significant left ventricular (LV) systolic and/or diastolic dysfunction.
DESIGN, SETTING, AND PARTICIPANTS: The St Vincent's Screening to Prevent Heart Failure Study, a parallel-group randomized trial involving 1374 participants with cardiovascular risk factors (mean age, 64.8 [SD, 10.2] years) recruited from 39 primary care practices in Ireland between January 2005 and December 2009 and followed up until December 2011 (mean follow-up, 4.2 [SD, 1.2] years).
INTERVENTION: Patients were randomly assigned to receive usual primary care (control condition; n=677) or screening with BNP testing (n=697). Intervention-group participants with BNP levels of 50 pg/mL or higher underwent echocardiography and collaborative care between their primary care physician and specialist cardiovascular service.
MAIN OUTCOMES AND MEASURES: The primary end point was prevalence of asymptomatic LV dysfunction with or without newly diagnosed heart failure. Secondary end points included emergency hospitalization for arrhythmia, transient ischemic attack, stroke, myocardial infarction, peripheral or pulmonary thrombosis/embolus, or heart failure.
RESULTS: A total of 263 patients (41.6%) in the intervention group had at least 1 BNP reading of 50 pg/mL or higher. The intervention group underwent more cardiovascular investigations (control, 496 per 1000 patient-years vs intervention, 850 per 1000 patient-years; incidence rate ratio, 1.71; 95% CI, 1.61-1.83; P<.001) and received more renin-angiotensin-aldosterone system-based therapy at follow-up (control, 49.6%; intervention, 56.5%; P=.01). The primary end point of LV dysfunction with or without heart failure was met in 59 (8.7%) of 677 in the control group and 37 (5.3%) of 697 in the intervention group (odds ratio [OR], 0.55; 95% CI, 0.37-0.82; P = .003). Asymptomatic LV dysfunction was found in 45 (6.6%) of 677 control-group patients and 30 (4.3%) of 697 intervention-group patients (OR, 0.57; 95% CI, 0.37-0.88; P = .01). Heart failure occurred in 14 (2.1%) of 677 control-group patients and 7 (1.0%) of 697 intervention-group patients (OR, 0.48; 95% CI, 0.20-1.20; P = .12). The incidence rates of emergency hospitalization for major cardiovascular events were 40.4 per 1000 patient-years in the control group vs 22.3 per 1000 patient-years in the intervention group (incidence rate ratio, 0.60; 95% CI, 0.45-0.81; P = .002).
CONCLUSION AND RELEVANCE: Among patients at risk of heart failure, BNP-based screening and collaborative care reduced the combined rates of LV systolic dysfunction, diastolic dysfunction, and heart failure.
TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00921960.
Resumo:
Introduction : Insulation defects with externalized conductors have been reported in the St. Jude Riata(®) family of defibrillation leads (St. Jude Medical, Sylmar, CA, USA). The objective of the Northern Ireland Riata(®) lead screening program was to identify insulation defects and externalized conductors by systematic fluoroscopic and electrical assessment in a prospectively defined cohort of patients. We sought to estimate the prevalence, identify risk factors, and determine the natural history of this abnormality. Methods : All patients with a Riata(®) lead under follow-up at the Royal Victoria Hospital were invited for fluoroscopic imaging and implantable cardioverter-defibrillator lead parameter checks. Fluoroscopic images were read independently by two cardiologists and the presence of externalized conductors was classified as positive, negative, or borderline. Results: One hundred and sixty-five of 212 patients with a Riata lead were evaluated by fluoroscopy and lead parameter measurements. The mean duration after implantation was 3.98+/-1.43 years. After screening 25 (15%) patients were classified as positive, 137 (83%) negative, and three (1.8%) borderline. Time since implantation (P = 0.001), presence of a single coil lead (P = 0.042), and patient age (P = 0.034) were significantly associated with externalized conductors. The observed rate of externalized conductors was 26.9% for 8-French and 4.7% for 7-French leads. No leads that were identified prospectively with externalized conductors had electrical abnormalities. Seven of 25 (28%) patients had a defective lead extracted by the end of this screening period. Conclusion: A significant proportion (15%) of patients with a Riata lead had an insulation breach 4 years after implantation. High-resolution fluoroscopic imaging in at least two orthogonal views is required to identify this abnormality. (PACE 2012;35:1498-1504).
Resumo:
OBJECTIVE: To assess and improve the accuracy of lay screeners compared with vision professionals in detecting visual impairment in secondary schoolchildren in rural China. METHODS: After brief training, 32 teachers and a team of vision professionals independently measured vision in 1892 children in Xichang. The children also underwent vision measurement by health technicians in a concurrent government screening program. RESULTS: Of 32 teachers, 28 (87.5%) believed that teacher screening was worthwhile. Sensitivity (93.5%) and specificity (91.2%) of teachers detecting uncorrected presenting visual acuity of 20/40 or less were better than for presenting visual acuity (sensitivity, 85.2%; specificity, 84.8%). Failure of teachers to identify children owning but not wearing glasses and teacher bias toward better vision in children wearing glasses explain the worse results for initial vision. Wearing glasses was the student factor most strongly predictive of inaccurate teacher screening (P < .001). The sensitivity and specificity of the government screening program detecting low presenting visual acuity were 86.7% and 28.7%, respectively. CONCLUSIONS: Teacher vision screening after brief training can achieve accurate results in this setting, and there is support among teachers for screening. Screening of uncorrected rather than presenting visual acuity is recommended in settings with a high prevalence of corrected and uncorrected refractive error. Low specificity in the government program renders it ineffective.
Resumo:
An intelligent ink, previously shown to be capable of rapidly assessing photocatalytic activity, was simply applied via a felt-pen onto a commercially available piece of Activ (TM) self-cleaning glass. The ink, comprising of redox dye resazurin and the sacrificial electron donor glycerol within an aqueous hydroxy ethyl cellulose (HEC) polymer media, was photocatalytically degraded in a two-step process. The key initial stage was the photo-reductive conversion of resazurin to resorufin, whereby a colour change from blue to pink occurred. The latter stage was the subsequent photo-reduction of the resorufin, where a slower change from pink to colourless was seen. Red and green components of red-green-blue colour extracted from flat-bed scanner digital images of resazurin ink coated photocatalytic films at intervals during the photocatalysis reaction were inversely proportional to the changes seen via UV-visible absorption spectroscopy and indicative of reaction kinetics. A 3 x 3 grid of intelligent ink was drawn onto a piece of Activ (TM) and a glass blank. The photocatalysis reaction was monitored solely by flat-bed digital scanning. Red-green-blue values of respective positions on the grid were extracted using a custom-built program entitled RGB Extractor (c). The program was capable of extracting a number of 5 x 5 pixel averages of red-green-blue components simultaneously. Allocation of merely three coordinates allowed for the automatic generation of a grid, with scroll-bars controlling the number of positions to be extracted on the grid formed. No significant change in red and green components for any position on the glass blank was observed; however, the Activ (TM) film displayed a homogenous photo-reduction of the dye, reaching maxima in red and minima in green components in 23 +/- 3 and 14 +/- 2 min, respectively. A compositionally graded N-doped titania film synthesised in house via a combinatorial APCVD reaction was also photocatalytically tested by this method where 247 positions on a 13 x 19 grid were simultaneously analysed. The dramatic variation in photocatalysis observed was rapidly quantified for all positions (2-3 hours) allowing for correlations to be made between thicknesses and N : Ti% compositions attained from Swanepoel and WDX analysis, respectively. N incorporation within this system was found to be detrimental to film activity for the photocatalysis reaction of intelligent ink under 365 nm light.
Resumo:
Despite the significant burden of cervical cancer, Malaysia like many middle-income countries relies on opportunistic cervical screening as opposed to a more organized population-based program. The aim of this study was to ascertain the effectiveness of a worksite screening initiative upon Papanicolaou smear test (Pap test) uptake among educated working women in Malaysia.
Resumo:
Rheumatic heart disease (RHD) is the largest cardiac cause of morbidity and mortality in the world's youth. Early detection of RHD through echocardiographic screening in asymptomatic children may identify an early stage of disease, when secondary prophylaxis has the greatest chance of stopping disease progression. Latent RHD signifies echocardiographic evidence of RHD with no known history of acute rheumatic fever and no clinical symptoms.
OBJECTIVE: Determine the prevalence of latent RHD among children ages 5-16 in Lilongwe, Malawi.
DESIGN: This is a cross-sectional study in which children ages 5 through 16 were screened for RHD using echocardiography.
SETTING: Screening was conducted in 3 schools and surrounding communities in the Lilongwe district of Malawi between February and April 2014.
OUTCOME MEASURES: Children were diagnosed as having no, borderline, or definite RHD as defined by World Heart Federation criteria. The primary reader completed offline reads of all studies. A second reader reviewed all of the studies diagnosed as RHD, plus a selection of normal studies. A third reader served as tiebreaker for discordant diagnoses. The distribution of results was compared between gender, location, and age categories using Fisher's exact test.
RESULTS: The prevalence of latent RHD was 3.4% (95% CI = 2.45, 4.31), with 0.7% definite RHD and 2.7% borderline RHD. There was no significant differences in prevalence between gender (P = .44), site (P = .6), urban vs. peri-urban (P = .75), or age (P = .79). Of those with definite RHD, all were diagnosed because of pathologic mitral regurgitation (MR) and 2 morphologic features of the mitral valve. Of those with borderline RHD, most met the criteria by having pathological MR (92.3%).
CONCLUSION: Malawi has a high rate of latent RHD, which is consistent with other results from sub-Saharan Africa. This study strongly supports the need for a RHD prevention and control program in Malawi.
Resumo:
BACKGROUND: Although most gastrointestinal stromal tumours (GIST) carry oncogenic mutations in KIT exons 9, 11, 13 and 17, or in platelet-derived growth factor receptor alpha (PDGFRA) exons 12, 14 and 18, around 10% of GIST are free of these mutations. Genotyping and accurate detection of KIT/PDGFRA mutations in GIST are becoming increasingly useful for clinicians in the management of the disease. METHOD: To evaluate and improve laboratory practice in GIST mutation detection, we developed a mutational screening quality control program. Eleven laboratories were enrolled in this program and 50 DNA samples were analysed, each of them by four different laboratories, giving 200 mutational reports. RESULTS: In total, eight mutations were not detected by at least one laboratory. One false positive result was reported in one sample. Thus, the mean global rate of error with clinical implication based on 200 reports was 4.5%. Concerning specific polymorphisms detection, the rate varied from 0 to 100%, depending on the laboratory. The way mutations were reported was very heterogeneous, and some errors were detected. CONCLUSION: This study demonstrated that such a program was necessary for laboratories to improve the quality of the analysis, because an error rate of 4.5% may have clinical consequences for the patient.