3 resultados para Screening-program

em CaltechTHESIS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dissertation presents a political and economic history of the federal government's program to commercialize photovoltaic energy for terrestrial use. Chapter 1 is a detailed history of the program. Chapter 2 is a brief review of the Congressional roll call voting literature. Chapter 3 develops PV benefit measures at the state and Congressional district level necessary for an econometric analysis of PV roll call voting. Chapter 4 presents the econometric analysis.

Because PV power was considerably more expensive than conventional power, the program was designed to make PV a significant power source in the long term, emphasizing research and development, although sizeable amounts have been spent for procurement (direct government purchases and indirectly through tax credits). The decentralized R and D program pursued alternative approaches in parallel, with subsequent funding dependent on earlier progress. Funding rose rapidly in the 1970s before shrinking in the 1980s. Tax credits were introduced in 1978, with the last of the credits due to expire this year.

Major issues in the program have been the appropriate magnitude of demonstrations and government procurement, whether decentralized, residential use or centralized utility generation would first be economic, the role of storage in PV, and the role of PV in a utility's generation mix.

Roll call voting on solar energy (all votes analyzed occurred from 1975-1980) was influenced in a cross-sectional sense by all the influences predicted: party and ideology, local economic benefits of the technology, local PV federal spending and manufacturing, and appropriations committee membership. The cross-sectional results for ideology are consistent with the strongly ideological character of solar energy politics and the timing of funding increases and decreases discussed in Chapter 1. Local PV spending and manufacturing was less significant than ideology or the economic benefits of the technology. Because time series analysis of the votes was not possible, it is not possible to test the role of economic benefits to the nation as a whole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wide field-of-view (FOV) microscopy is of high importance to biological research and clinical diagnosis where a high-throughput screening of samples is needed. This thesis presents the development of several novel wide FOV imaging technologies and demonstrates their capabilities in longitudinal imaging of living organisms, on the scale of viral plaques to live cells and tissues.

The ePetri Dish is a wide FOV on-chip bright-field microscope. Here we applied an ePetri platform for plaque analysis of murine norovirus 1 (MNV-1). The ePetri offers the ability to dynamically track plaques at the individual cell death event level over a wide FOV of 6 mm × 4 mm at 30 min intervals. A density-based clustering algorithm is used to analyze the spatial-temporal distribution of cell death events to identify plaques at their earliest stages. We also demonstrate the capabilities of the ePetri in viral titer count and dynamically monitoring plaque formation, growth, and the influence of antiviral drugs.

We developed another wide FOV imaging technique, the Talbot microscope, for the fluorescence imaging of live cells. The Talbot microscope takes advantage of the Talbot effect and can generate a focal spot array to scan the fluorescence samples directly on-chip. It has a resolution of 1.2 μm and a FOV of ~13 mm2. We further upgraded the Talbot microscope for the long-term time-lapse fluorescence imaging of live cell cultures, and analyzed the cells’ dynamic response to an anticancer drug.

We present two wide FOV endoscopes for tissue imaging, named the AnCam and the PanCam. The AnCam is based on the contact image sensor (CIS) technology, and can scan the whole anal canal within 10 seconds with a resolution of 89 μm, a maximum FOV of 100 mm × 120 mm, and a depth-of-field (DOF) of 0.65 mm. We also demonstrate the performance of the AnCam in whole anal canal imaging in both animal models and real patients. In addition to this, the PanCam is based on a smartphone platform integrated with a panoramic annular lens (PAL), and can capture a FOV of 18 mm × 120 mm in a single shot with a resolution of 100─140 μm. In this work we demonstrate the PanCam’s performance in imaging a stained tissue sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Everett interpretation of quantum mechanics is an increasingly popular alternative to the traditional Copenhagen interpretation, but there are a few major issues that prevent the widespread adoption. One of these issues is the origin of probabilities in the Everett interpretation, which this thesis will attempt to survey. The most successful resolution of the probability problem thus far is the decision-theoretic program, which attempts to frame probabilities as outcomes of rational decision making. This marks a departure from orthodox interpretations of probabilities in the physical sciences, where probabilities are thought to be objective, stemming from symmetry considerations. This thesis will attempt to offer evaluations on the decision-theoretic program.