15 resultados para Pads
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
Resumo:
OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?
DESIGN: Animal study.
SETTING: University research laboratory.
SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.
INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).
MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).
CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.
Resumo:
An algorithm based only on the impedance cardiogram (ICG) recorded through two defibrillation pads, using the strongest frequency component and amplitude, incorporated into a defibrillator could determine circulatory arrest and reduce delays in starting cardiopulmonary resuscitation (CPR). Frequency analysis of the ICG signal is carried out by integer filters on a sample by sample basis. They are simpler, lighter and more versatile when compared to the FFT. This alternative approach, although less accurate, is preferred due to the limited processing capacity of devices that could compromise real time usability of the FFT. These two techniques were compared across a data set comprising 13 cases of cardiac arrest and 6 normal controls. The best filters were refined on this training set and an algorithm for the detection of cardiac arrest was trained on a wider data set. The algorithm was finally tested on a validation set. The ICG was recorded in 132 cardiac arrest patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with a sensitivity of 81.1% (77.6-84.3) and specificity of 97.1% (96.7-97.4) for the validation set (95% confidence intervals). Automated defibrillators with integrated ICG analysis have the potential to improve emergency care by lay persons enabling more rapid and appropriate initiation of CPR and when combined with ECG analysis they could improve on the detection of cardiac arrest.
Resumo:
Background: Hip protectors are protective pads designed to cover the greater trochanter and attenuate or disperse the force of a fall sufficiently to prevent a hip fracture. Promising results from randomised controlled trials in nursing homes have resulted in hip protectors being widely recommended in the health care literature and in national guidelines. Objectives: The objectives of the study were to identify characteristics of individual residents, and the organisational features of the homes in which they live, which may affect adherence to wearing hip protectors. Design: An observational, correlation study designed to identify factors related to adherence. Setting: Forty nursing and residential homes in the UK. Participants: 1346 residents of the homes who were not confined to bed and with no pressure sore on the hip. Methods: The introduction of an evidence-based policy to offer Safehips hip protectors to residents free of charge and with support from a nurse facilitator. Adherence to wearing the hip protectors was observed over 72 weeks. Results: Initial acceptance of the hip protectors was 37.2%. Continued adherence was 23.9% at 24 weeks; 23.2% at 48 weeks; and 19.9% at 72 weeks. Greater adherence was associated with the following individual resident characteristics: a greater degree of dependency (95% CI 1.39 - m3.78) and cognitive impairment (95% CI 1.01 - 2.98); being male rather than female (95% CI 1.06 - 2.48). Greater adherence was also associated with the following organisational characteristics of homes: fewer changes of senior manager during the study period (95% CI 1.01 - 8.51), and being resident in a home with a resident profile showing a greater proportion of residents with a higher degree of dependency (95% CI 1.04 - 1.27). There was wide a variation in the degree of success in implementation between homes (adherence of 0 - 100% at 24 weeks). Conclusions: Those implementing a policy of introducing hip protectors into nursing and residential homes should consider targeting residents with cognitive impairment. Such residents are at greater risk of hip fracture and appear to be more likely to continue wearing hip protectors. Those charged with implementing changes inpractice or policy should consider how the context for implementation can be optimised to increase the likelihood of success.
Resumo:
The gametogenic and spat settlement patterns of two Mytihis edulis beds were studied in Dundrum Inner Bay, Northern Ireland. There was evidence of gonad development throughout the year with the main development period between November and March. Spawning was protracted, lasting from May to November. Slight inter-annual and inter-population differences in the riming of the phases were observed but the cycles at both beds were broadly similar to each other and to those of other British and Irish sites. Settlement occurred throughout the year and there was evidence of both primary and secondary spat settlement at both sites. Although the reproductive cycles were similar, distinct seasonal and inter-site differences in spatfall were apparent. At the Downshire Bridge bed, settlement peaked during summer and was dominated by spat in the 0•;5-1•0 mm size range. At Ballykinler, settlement levels were highest in the winter months and larger (>1 mm) spat dominated the samples. The orientation of spat collection pads also significantly affected numbers of the larger (>1 mm) spat. Collectors facing the flood tide attracted significantly more secondary settlers than ebb-facing collectors. This effect varied seasonally and was greater at the Ballykinler bed. It is suggested that hydrodynamic regimes may be an important factor in the differences in settlement patterns of M. edulis.
Resumo:
A new, front-end image processing chip is presented for real-time small object detection. It has been implemented using a 0.6 µ, 3.3 V CMOS technology and operates on 10-bit input data at 54 megasamples per second. It occupies an area of 12.9 mm×13.6 mm (including pads), dissipates 1.5 W, has 92 I/O pins and is to be housed in a 160-pin ceramic quarter flat-pack. It performs both one- and two-dimensional FIR filtering and a multilayer perceptron (MLP) neural network function using a reconfigurable array of 21 multiplication-accumulation cells which corresponds to a window size of 7×3. The chip can cope with images of 2047 pixels per line and can be cascaded to cope with larger window sizes. The chip performs two billion fixed point multiplications and additions per second.
Resumo:
5-HT-immunoreactivity in Entobdella soleae was found to be extensive throughout both the central and peripheral nervous systems, with the strongest staining occurring in the innervation of the forebody, most notably in the paired cerebral ganglia, pharynx and adhesive pads. In the reproductive system, staining was evident throughout the numerous cell bodies and fibres innervating the musculature of the egg-assembly apparatus. The haptor contained an extensive array of serotoninergic fibres derived from the main longitudinal cords; this array was associated with the haptoral muscles and sclerites, and possibly with the ventral sensory papillae.
Resumo:
The recent adiabatic saddle-point method of Shearer et al. [ Phys. Rev. A 84 033409 (2011)] is applied to study strong-field photodetachment of H- by few-cycle linearly polarized laser pulses of frequencies near the two-photon detachment threshold. The behavior of the saddle points in the complex-time plane for a range of laser parameters is explored. A detailed analysis of the influence of laser intensities [(2×1011)–(6.5 × 1011) W/cm2], midinfrared laser wavelengths (1800–2700 nm), and various values of the carrier envelope phase (CEP) on (i) three-dimensional probability detachment distributions, (ii) photoangular distributions (PADs), (iii) energy spectra, and (iv) momentum distributions are presented. Examination of the probability distributions and PADs reveal main lobes and jetlike structures. Bifurcation phenomena in the probability distributions and PADs are also observed as the wavelength and intensity increase. Our simulations show that the (i) probability distributions, (ii) PADs, and (iii) energy spectra are extremely sensitive to the CEP and thus measuring such distributions provides a useful tool for determining this phase. The symmetrical properties of the electron momentum distributions are also found to be strongly correlated with the CEP and this provides an additional robust method for measuring the CEP of a laser pulse. Our calculations further show that for a three-cycle pulse inclusion of all eight saddle points is required in the evaluation of the transition amplitude to yield an accurate description of the photodetachment process. This is in contrast to recent results for a five-cycle pulse.
Resumo:
OBJECTIVE: To assess the impedance cardiogram recorded by an automated external defibrillator during cardiac arrest to facilitate emergency care by lay persons. Lay persons are poor at emergency pulse checks (sensitivity 84%, specificity 36%); guidelines recommend they should not be performed. The impedance cardiogram (dZ/dt) is used to indicate stroke volume. Can an impedance cardiogram algorithm in a defibrillator determine rapidly circulatory arrest and facilitate prompt initiation of external cardiac massage?
DESIGN: Clinical study.
SETTING: University hospital.
PATIENTS: Phase 1 patients attended for myocardial perfusion imaging. Phase 2 patients were recruited during cardiac arrest. This group included nonarrest controls.
INTERVENTIONS: The impedance cardiogram was recorded through defibrillator/electrocardiographic pads oriented in the standard cardiac arrest position.
MEASUREMENTS AND MAIN RESULTS: Phase 1: Stroke volumes from gated myocardial perfusion imaging scans were correlated with parameters from the impedance cardiogram system (dZ/dt(max) and the peak amplitude of the Fast Fourier Transform of dZ/dt between 1.5 Hz and 4.5 Hz). Multivariate analysis was performed to fit stroke volumes from gated myocardial perfusion imaging scans with linear and quadratic terms for dZ/dt(max) and the Fast Fourier Transform to identify significant parameters for incorporation into a cardiac arrest diagnostic algorithm. The square of the peak amplitude of the Fast Fourier Transform of dZ/dt was the best predictor of reduction in stroke volumes from gated myocardial perfusion imaging scans (range = 33-85 mL; p = .016). Having established that the two pad impedance cardiogram system could detect differences in stroke volumes from gated myocardial perfusion imaging scans, we assessed its performance in diagnosing cardiac arrest. Phase 2: The impedance cardiogram was recorded in 132 "cardiac arrest" patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with sensitivities and specificities (+/- exact 95% confidence intervals) of 89.1% (85.4-92.1) and 99.6% (99.4-99.7; training) and 81.1% (77.6-84.3) and 97% (96.7-97.4; validation).
CONCLUSIONS: The impedance cardiogram algorithm is a significant marker of circulatory collapse. Automated defibrillators with an integrated impedance cardiogram could improve emergency care by lay persons, enabling rapid and appropriate initiation of external cardiac massage.
Resumo:
An algorithm has been developed for a Public Access Defibrillator which utilizes distinctive features from the impedance cardiogram (ICG) recorded via defibrillator pads to advise both lay users and minimally trained bystanders to ensure CPR effectiveness. Following ethical approval, data were collected and marked. CPR was administered by trained personnel. 211 cases were gathered and the training set included 106 cases. A retrospective analysis was carried out of simultaneously recorded ECG and ICG. The speed of compressions was calculated by counting the outstanding waves in the ICG during CPR. Also if the base-to-peak amplitude of the ICG is greater than a minimum threshold, the corresponding compressions were classified as being applied with adequate force. For the validation set, adequate speed was detected with 91.45% sensitivity and 96.27% specificity (79826s) and adequate force with 99.94% sensitivity and 97.91% specificity (91973s). © 2011 CCAL.
Resumo:
Frustration – the inability to simultaneously satisfy all interactions – occurs in a wide range of systems including neural networks, water ice and magnetic systems. An example of the latter is the so called spin-ice in pyrochlore materials [1] which have attracted a lot of interest not least due to the emergence of magnetic monopole defects when the ‘ice rules’ governing the local ordering breaks down [2]. However it is not possible to directly measure the frustrated property – the direction of the magnetic moments – in such spin ice systems with current experimental techniques. This problem can be solved by instead studying artificial spin-ice systems where the molecular magnetic moments are replaced by nanoscale ferromagnetic islands [3-8]. Two different arrangements of the ferromagnetic islands have been shown to exhibit spin ice behaviour: a square lattice maintaining four moments at each vertex [3,8] and the Kagome lattice which has only three moments per vertex but equivalent interactions between them [4-7]. Magnetic monopole defects have been observed in both types of lattices [7-8]. One of the challenges when studying these artificial spin-ice systems is that it is difficult to arrive at the fully demagnetised ground-state [6-8].
Here we present a study of the switching behaviour of building blocks of the Kagome lattice influenced by the termination of the lattice. Ferromagnetic islands of nominal size 1000 nm by 100 nm were fabricated in five island blocks using electron-beam lithography and lift-off techniques of evaporated 18 nm Permalloy (Ni80Fe20) films. Each block consists of a central island with four arms terminated by a different number and placement of ‘injection pads’, see Figure 1. The islands are single domain and magnetised along their long axis. The structures were grown on a 50 nm thick electron transparent silicon nitride membrane to allow TEM observation, which was back-coated with a 5 nm film of Au to prevent charge build-up during the TEM experiments.
To study the switching behaviour the sample was subjected to a magnetic field strong enough to magnetise all the blocks in one direction, see Figure 1. Each block obeys the Kagome lattice ‘ice-rules’ of “2-in, 1-out” or “1-in, 2-out” in this fully magnetised state. Fresnel mode Lorentz TEM images of the sample were then recorded as a magnetic field of increasing magnitude was applied in the opposite direction. While the Fresnel mode is normally used to image magnetic domain structures [9] for these types of samples it is possible to deduce the direction of the magnetisation from the Lorentz contrast [5]. All images were recorded at the same over-focus judged to give good Lorentz contrast.
The magnetisation was found to switch at different magnitudes of the applied field for nominally identical blocks. However, trends could still be identified: all the blocks with any injection pads, regardless of placement and number, switched the direction of the magnetisation of their central island at significantly smaller magnitudes of the applied magnetic field than the blocks without injection pads. It can therefore be concluded that the addition of an injection pad lowers the energy barrier to switching the connected island, acting as a nucleation site for monopole defects. In these five island blocks the defects immediately propagate through to the other side, but in a larger lattice the monopoles could potentially become trapped at a vertex and observed [10].
References
[1] M J Harris et al, Phys Rev Lett 79 (1997) p.2554.
[2] C Castelnovo, R Moessner and S L Sondhi, Nature 451 (2008) p. 42.
[3] R F Wang et al, Nature 439 (2006) 303.
[4] M Tanaka et al, Phys Rev B 73 (2006) 052411.
[5] Y Qi, T Brintlinger and J Cumings, Phys Rev B 77 (2008) 094418.
[6] E Mengotti et al, Phys Rev B 78 (2008) 144402.
[7] S Ladak et al, Nature Phys 6 (2010) 359.
[8] C Phatak et al, Phys Rev B 83 (2011) 174431.
[9] J N Chapman, J Phys D 17 (1984) 623.
[10] The authors gratefully acknowledge funding from the EPSRC under grant number EP/D063329/1.
Resumo:
Email
Print
Request Permissions
A compact V-band active power detector using Infineon 0.35 µm SiGe HBT process (fT/fmax =170/250 GHz) is described. The total chip area is only 0.35×0.8 mm2 including all pads. This design exhibits a dynamic range larger than 20 dB over the frequency range from 55 GHz to 67 GHz. It also offers a simple and low-power application potential as an envelop detector in multi-Gbps high data rate demodulators for OOK/ASK etc.
Resumo:
Purpose: We reviewed the outcome of cuff downsizing with an artificial urinary sphincter for treating recurrent incontinence due to urethral atrophy.
Materials and Methods: We analyzed the records of 17 patients in a 7-year period in whom clinical, radiological and urodynamic evidence of urethral atrophy was treated with cuff downsizing. Cuff downsizing was accomplished by removing the existing cuff and replacing it with a 4 cm. cuff within the established false capsule. Incontinence and satisfaction parameters before and after the procedure were assessed by a validated questionnaire.
Results: Mean patient age was 70 years (range 62 to 79). Average time to urethral atrophy was 31 months (range 5 to 96) after primary sphincter implantation. Mean followup after downsizing was 22 months (range 1 to 64). Cuff downsizing caused a mean decrease of 3.9 to 0.5 pads daily. The number of severe leakage episodes decreased from a mean of 5.4 to 2.1 The mean SEAPI (stress leakage, emptying, anatomy, protection, inhibition) score decreased from 8.2 to 2.4. Patient satisfaction increased from 15% to 80% after cuff downsizing. In 1 patient an infected cuff required complete removal of the device.
Conclusions: Patient satisfaction and continence parameters improved after cuff downsizing. We believe that this technique is a simple and effective method of restoring continence after urethral atrophy.
Resumo:
To alleviate practical limitations in the design of mm-wave on-chip image-reject filters, systematic design methodologies are presented. Three low-order filters with high-selectivity and low-loss characteristics are designed and compared. Transmission zeroes are created by means of a quarter-wave transmission line (filter 1) and a series LC resonator (filters 2 and 3). Implemented on SiGe, the filters occupy 0.125, 0.064, and 0.079 mm2 chip area including pads. The measured transmission
losses across 81-86 GHz E-Band frequency range are 3.6-5.2 dB for filter 1, 3.1-4.7 dB for filter 2 and 3.6-5 dB for filter 3 where rejection levels at the image band are greater than 30 dB.
Resumo:
The implementation of a dipole antenna co-designed and monolithically integrated with a low noise amplifier (LNA) on low resistivity Si substrate (20 Omega . cm) manufactured in 0.35 mu m commercial SiGe HBT process with f(T)/f(max) of 170 GHz and 250 GHz is investigated theoretically and experimentally. An air gap is introduced between the chip and a reflective ground plane, leading to substantial improvements in efficiency and gain. Moreover, conjugate matching conditions between the antenna and the LNA are exploited, enhancing power transfer between without any additional matching circuit. A prototype is fabricated and tested to validate the performance. The measured 10-dB gain of the standalone LNA is centered at 58 GHz with a die size of 0.7 mm x 0.6 mm including all pads. The simulated results showed antenna directivity of 5.1 dBi with efficiency higher than 70%. After optimization, the co-designed LNA-Antenna chip with a die size of 3 mm x 2.8 mm was characterized in anechoic chamber environment. A maximum gain of higher than 12 dB was obtained.
Resumo:
Phalloidin fluorescence technique, enzyme cytochemistry and immunocytochemistry in conjunction with confocal scanning laser microscopy were used for the first time to describe the nervous and muscle systems of the viviparous monogenean parasite, Gyrodactylus rysavyi inhabiting the gills and skin of the Nile catfish Clarias gariepinus. The body wall muscles are composed of an outer layer of circular fibres, an intermediate layer of paired longitudinal fibres and an inner layer of well-spaced bands of diagonal fibres arranged in two crossed directions. The musculature of the pharynx, intestine, reproductive tract and the most prominent muscles of the haptor were also described. Two characteristic muscular pads were found lying in the anterior region of the haptor in close contact with the hamuli. To each one of these pads, a group of ventral extrinsic muscles was connected. The role of this ventral extrinsic muscle in the body movement was discussed. The mechanism operating the marginal hooklets was also discussed. The central nervous system (CNS) consists of paired cerebral ganglia from which three pairs of longitudinal ventral, lateral and dorsal nerve cords arise. The nerve cords are connected at intervals by many transverse connectives. The CNS is better developed ventrally than dorsally or laterally and it has the highest reactivity for all neuroactive substances examined. Both the central and the peripheral nervous system (PNS) are bilaterally symmetrical. Structural and functional correlates of the neuromusculature of the pharynx, haptor and reproductive tracts were explained. The results implicated acetylcholine, FMRFamide-related peptides (FaRPs) and serotonin in sensory and motor function. The results were compared with those of the monogeneans Macrogyrodactylus clarii and M. congolensis inhabiting the gills and skin respectively of the same host fish C. gariepinus.