168 resultados para GAMMA-RAYS

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Context. The detection and measurement of gamma-ray lines from the decaychain of 56Ni provides unique information about the explosionin supernovae. SN2014J at 3.3 Mpc is a sufficiently-nearby supernova oftype Ia so that such measurements have been feasible with the gamma-rayspectrometer SPI on ESA's INTEGRAL gamma-ray observatory.

Aims:The 56Ni freshly produced in the supernova is understood topower the optical light curve, because it emits gamma rays upon itsradioactive decay first to 56Co and then to 56Fe.Gamma-ray lines from 56Co decay are expected to becomedirectly visible through the white dwarf material several weeks afterthe explosion, as they progressively penetrate the overlying material ofthe supernova envelope, which is diluted as it expands. The lines areexpected to be Doppler-shifted or broadened from the kinematics of the56Ni ejecta. We aim to exploit high-resolution gamma-rayspectroscopy with the SPI spectrometer on INTEGRAL toward constrainingthe 56Ni distribution and kinematics in this supernova.

Methods: We use the observations with the SPI spectrometer onINTEGRAL, together with an improved instrumental background method.

Results: We detect the two main lines from 56Co decay at847 and 1238 keV, which are significantly Doppler-broadened, and atintensities (3.65 ± 1.21) × 10-4 and (2.27± 0.69) × 10-4 ph cm-2s-1, respectively, at their brightness maximum. We measuretheir rise toward a maximum after about 60-100 days and a declinethereafter. The intensity ratio of the two lines is found to beconsistent with expectations from 56Co decay (0.62 ±0.28 at brightness maximum, the expected ratio is 0.68). We find thatthe broad lines seen in the late, gamma-ray transparent phase are notrepresentative of the early gamma-ray emission, and notice instead thatthe emission spectrum is complex and irregular until the supernova isfully transparent to gamma rays, with progressive uncovering of the bulkof 56Ni. We infer that the explosion morphology is notspherically symmetric, both in the distribution of 56Ni andin the unburnt material which occults the 56Co emission.After we compare light curves from different plausible models, theresulting 56Ni mass is determined to be 0.49 ± 0.09M⊙.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

γ-Ray sources are among the most fundamental experimental tools currently available to modern physics. As well as the obvious benefits to fundamental research, an ultra-bright source of γ-rays could form the foundation of scanning of shipping containers for special nuclear materials and provide the bases for new types of cancer therapy.

However, for these applications to prove viable, γ-ray sources must become compact and relatively cheap to manufacture. In recent years, advances in laser technology have formed the cornerstone of optical sources of high energy electrons which already have been used to generate synchrotron radiation on a compact scale. Exploiting the scattering induced by a second laser, one can further enhance the energy and number of photons produced provided the problems of synchronisation and compact γ-ray detection are solved.

Here, we report on the work that has been done in developing an all-optical and hence, compact non-linear Thomson scattering source, including the new methods of synchronisation and compact γ-ray detection. We present evidence of the generation of multi-MeV (maximum 16–18 MeV) and ultra-high brilliance (exceeding 1020 photons s−1mm−2mrad−2 0.1% BW at 15 MeV) γ-ray beams. These characteristics are appealing for the paramount practical applications mentioned above.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The application of high intensity laser-produced gamma rays is discussed with regard to picosecond resolution deep-penetration radiography. The spectrum and angular distribution of these gamma rays is measured using an array of thermoluminescent detectors for both an underdense (gas) target and an overdense (solid) target. It is found that the use of an underdense target in a laser plasma accelerator configuration produces a much more intense and directional source. The peak dose is also increased significantly. Radiography is demonstrated in these experiments and the source size is also estimated. (C) 2002 American Institute of Physics.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A controlled study was undertaken to assess the effect of gamma irradiation on post-traumatic intraocular cellular proliferation. A standard perforating injury in the posterior segment of the rabbit eye was used to induce intraocular cellular proliferation and vitreo-retinal membrane formation. The site of injury was irradiated with an ophthalmic Cobalt60 applicator which provided a continuous source of gamma rays. Non-irradiated eyes developed traction retinal detachments associated with post-traumatic vitreo-retinal membranes. Irradiated eyes developed attenuated membranes or atrophic retinal scars, with the retina remaining attached. The membranes in non-irradiated eyes were highly cellular with abundant collagen, while irradiated membranes had fewer cells within a sparse collagen matrix. The episcleral fibroblasts, on autoradiographic studies appeared to be the main source of the cells that formed the proliferating tissue in both non-irradiated and irradiated eyes. In irradiated eyes both the inflammatory response and division of fibroblasts were delayed and reduced.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A novel design for a compact gamma-ray spectrometer is presented. The proposed system allows for spectroscopy of high-flux multi-MeV gamma-ray beams with MeV energy resolution in a compact design. In its basic configuration, the spectrometer exploits conversion of gamma-rays into electrons via Compton scattering in a low-Z material. The scattered electron population is then spectrally resolved using a magnetic spectrometer. The detector is shown to be effective for gamma-ray energies between 3 and 20 MeV. The main properties of the spectrometer are confirmed by Monte Carlo simulations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Context. Although the question of progenitor systems and detailed explosion mechanisms still remains a matter of discussion, it is commonly believed that Type Ia supernovae (SNe Ia) are production sites of large amounts of radioactive nuclei. Even though the gamma-ray emission due to radioactive decays is responsible for powering the light curves of SNe Ia, gamma rays themselves are of particular interest as a diagnostic tool because they directly lead to deeper insight into the nucleosynthesis and the kinematics of these explosion events. Aims: We study the evolution of gamma-ray line and continuum emission of SNe Ia with the objective of analyzing the relevance of observations in this energy range. We seek to investigate the chances for the success of future MeV missions regarding their capabilities for constraining the intrinsic properties and the physical processes of SNe Ia. Methods: Focusing on two of the most broadly discussed SN Ia progenitor scenarios - a delayed detonation in a Chandrasekhar-mass white dwarf (WD) and a violent merger of two WDs - we used three-dimensional explosion models and performed radiative transfer simulations to obtain synthetic gamma-ray spectra. Both chosen models produce the same mass of 56Ni and have similar optical properties that are in reasonable agreement with the recently observed supernova SN 2011fe. We examine the gamma-ray spectra with respect to their distinct features and draw connections to certain characteristics of the explosion models. Applying diagnostics, such as line and hardness ratios, the detection prospects for future gamma-ray missions with higher sensitivities in the MeV energy range are discussed. Results: In contrast to the optical regime, the gamma-ray emission of our two chosen models proves to be quite different. The almost direct connection of the emission of gamma rays to fundamental physical processes occurring in SNe Ia permits additional constraints concerning several explosion model properties that are not easily accessible within other wavelength ranges. Proposed future MeV missions such as GRIPS will resolve all spectral details only for nearby SNe Ia, but hardness ratio and light curve measurements still allow for a distinction of the two different models at 10 Mpc and 16 Mpc for an exposure time of 106 s. The possibility of detecting the strongest line features up to the Virgo distance will offer the opportunity to build up a first sample of SN Ia detections in the gamma-ray energy range and underlines the importance of future space observatories for MeV gamma rays.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method of measuring the temperature of the fast electrons produced in ultraintense laser-plasma interactions is described by inducing photonuclear reactions, in particular (gamma,n) and (gamma,3n) reactions in tantalum. Analysis of the gamma rays emitted by the daughter nuclei of these reactions using a germanium counter enables a relatively straightforward near real-time temperature measurement to be made. This is especially important for high temperature plasmas where alternative diagnostic techniques are usually difficult and time consuming. This technique can be used while other experiments are being conducted. (C) 2002 American Institute of Physics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An important difference between chemical agents that induce oxidative damage in DNA and ionizing radiation is that radiation-induced damage is clustered locally on the DNA, Both modelling and experimental studies have predicted the importance of clustering of lesions induced by ionizing radiation and its dependence on radiation quality. With increasing linear energy transfer, it is predicted that complex lesions will be formed within 1-20 bp regions of the DNA, As well as strand breaks, these sites may contain multiple damaged bases, We have compared the yields of single strand breaks (ssb) and double strand breaks (dsb) along with those produced by treatment of irradiated DNA with the enzyme endonuclease III, which recognizes a number of oxidized pyrimidines in DNA and converts them to strand breaks. Plasmid DNA was irradiated under two different scavenging conditions to test the involvement of OH radicals with either Co-60 gamma-rays or alpha-particles from a Pu-238 source. Under low scavenging conditions (10 mM Tris) gamma-irradiation induced 7.1x10(-7) ssb Gy/bp, which increased 3.7-fold to 2.6 x 10(-6) ssb Gy/bp with endo III treatment. In contrast the yields of dsb increased by 4.2-fold from 1.5 x 10(-8) to 6.3 x 10(-8) dsb Gy/bp, This equates to an additional 2.5% of the endo III-sensitive sites being converted to dsb on enzyme treatment. For alpha-particles this increased to 9%. Given that endo III sensitive sites may only constitute similar to 40% of the base lesions induced in DNA, this suggests that up to 6% of the ssb measured in X- and 22% in alpha-particle-irradiated DNA could have damaged bases associated with them contributing to lesion complexity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Particle-in-cell simulations of relativistic, weakly magnetized collisionless shocks show that particles can gain energy by repeatedly crossing the shock front. This requires scattering off self-generated small length-scale magnetic fluctuations. The radiative signature of this first-order Fermi acceleration mechanism is important for models of both the prompt and afterglow emission in gamma-ray bursts and depends on the strength parameter a = lambda e/delta B/mc(2) of the fluctuations (lambda is the length scale and vertical bar delta B vertical bar is the magnitude of the fluctuations). For electrons (and positrons), acceleration saturates when the radiative losses produced by the scattering cannot be compensated by the energy gained on crossing the shock. We show that this sets an upper limit on both the electron Lorentz factor gamma <10(6) (n/1 cm(-3))(-1/6)(-1/6) and on the energy of the photons radiated during the scattering process h omega(max) <40Max(a, 1)(n/1 cm(-3))(1/6)(-1/6) eV, where n is the number density of the plasma and (gamma) over bar is the thermal Lorentz factor of the downstream plasma, provided a <a(crit) similar to 10(6). This rules out "jitter" radiation on self-excited fluctuations with a <I as a source of gamma rays, although high-energy photons might still be produced when the jitter photons are upscattered in an analog of the synchrotron self-Compton process. In fluctuations with a > 1, radiation is generated by the standard synchrotron mechanism, and the maximum photon energy rises linearly with a, until saturating at 70 MeV, when a = a(crit).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Plaques constructed with 125I were used to irradiate the sites of perforating ocular injuries in rabbits. An approximate dose of 16Gy given over a period of 6 days was shown to significantly reduce intraocular cellular proliferation when irradiation was commenced within 24 hours after injury. If irradiation was delayed until day 5, this reduction in cellular proliferation and intraocular membrane formation did not occur. Smaller radiation doses of approximately 6Gy given within 24 hours post-injury and administered over 6 days also reduced the extent of cellular proliferation but was not as effective as the 16Gy dose.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Context: Mg VIII emission lines are observed in a range of astronomical objects such as the Sun, other cool stars and in the coronal line region of Seyfert galaxies. Under coronal conditions Mg VIII emits strongly in the extreme ultraviolet (EUV) and soft X-ray spectral regions which makes it an ideal ion for plasma diagnostics.

Aims. Two theoretical atomic models, consisting of 125 fine structure levels, are developed for the Mg VIII ion. The 125 levels arise from the 2s(2)2p, 2s(2)p2, 2p(3), 2s(2)3s, 2s(2)3p, 2s(2)3d, 2s2p3s, 2s2p3p, 2s2p3d, 2p(2)3s, 2p(2)3p and 2p(2)3d configurations. Electron impact excitation collision strengths and radiative transition probabilities are calculated for both Mg VIII models, compared with existing data, and the best model selected to generate a set of theoretical emission line intensities. The EUV lines, covering 312-790 angstrom, are compared with existing solar spectra (SERTS-89 and SUMER), while the soft X-ray transitions (69-97 angstrom) are examined for potential density diagnostic line ratios and also compared with the limited available solar and stellar observational data.

Methods. The R-matrix codes Breit-Pauli RMATRXI and RMATRXII are utilised, along with the PSTGF code, to calculate the collision strengths for two Mg VIII models. Collision strengths are averaged over a Maxwellian distribution to produce the corresponding effective collision strengths for use in astrophysical applications. Transition probabilities are also calculated using the CIV3 atomic structure code. The best data are then incorporated into the modelling code CLOUDY and line intensities generated for a range of electron temperatures and densities appropriate to solar and stellar coronal plasmas.

Results. The present effective collision strengths are compared with two previous calculations. Good levels of agreement are found with the most recent, but there are large differences with the other for forbidden transitions. The resulting line intensities compare favourably with the observed values from the SERTS-89 and SUMER spectra. Theoretical soft X-ray emission lines are presented and several density diagnostic line ratios examined, which are in reasonable agreement with the limited observational data available.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims. We investigated the response of the solar atmosphere to non-thermal electron beam heating using the radiative transfer and hydrodynamics modelling code RADYN. The temporal evolution of the parameters that describe the non-thermal electron energy distribution were derived from hard X-ray observations of a particular flare, and we compared the modelled and observed parameters.

Methods. The evolution of the non-thermal electron beam parameters during the X1.5 solar flare on 2011 March 9 were obtained from analysis of RHESSI X-ray spectra. The RADYN flare model was allowed to evolve for 110 s, after which the electron beam heating was ended, and was then allowed to continue evolving for a further 300 s. The modelled flare parameters were compared to the observed parameters determined from extreme-ultraviolet spectroscopy.

Results. The model produced a hotter and denser flare loop than that observed and also cooled more rapidly, suggesting that additional energy input in the decay phase of the flare is required. In the explosive evaporation phase a region of high-density cool material propagated upward through the corona. This material underwent a rapid increase in temperature as it was unable to radiate away all of the energy deposited across it by the non-thermal electron beam and via thermal conduction. A narrow and high-density (ne ≤ 1015 cm-3) region at the base of the flare transition region was the source of optical line emission in the model atmosphere. The collision-stopping depth of electrons was calculated throughout the evolution of the flare, and it was found that the compression of the lower atmosphere may permit electrons to penetrate farther into a flaring atmosphere compared to a quiet Sun atmosphere.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Superluminous supernovae (SLSNe) of Type Ic have a tendency to occur in faint host galaxies which are likely to have low mass and low metallicity. PTF12dam is one of the closest and best-studied superluminous explosions that has a broad and slowly fading light curve similar to SN 2007bi. Here we present new photometry and spectroscopy for PTF12dam from 200-500 d (rest frame) after peak and a detailed analysis of the host galaxy (SDSS J142446.21+461348.6 at z = 0.107). Using deep templates and image subtraction we show that the light curve can be fit with a magnetar model if escape of high-energy gamma rays is taken into account. The full bolometric light curve from -53 to +399 d (with respect to peak) cannot be fit satisfactorily with the pair-instability models. An alternative model of interaction with a dense circumstellar material (CSM) produces a good fit to the data although this requires a very large mass (˜13 M⊙) of hydrogen-free CSM. The host galaxy is a compact dwarf (physical size ˜1.9 kpc) and with Mg = -19.33 ± 0.10, it is the brightest nearby SLSN Ic host discovered so far. The host is a low-mass system (2.8 × 108 M⊙) with a star formation rate (5.0 M⊙ yr-1), which implies a very high specific star formation rate (17.9 Gyr-1). The remarkably strong nebular emission provide detections of the [O III] λ4363 and [O II] λλ7320, 7330auroral lines and an accurate oxygen abundance of 12 + log (O/H) = 8.05 ± 0.09. We show here that they are at the extreme end of the metallicity distribution of dwarf galaxies and propose that low metallicity is a requirement to produce these rare and peculiar SNe.