12 resultados para Downconversion mixer
em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast
The Fatigue Life of Bone Cement: how it is affected by mixer design, vacuum level and user technique
Resumo:
A hydrodynamic characterization of an industrially used gas-liquid contacting microchannel. device is discussed, viz. the micro bubble column of IMM. Furthermore, similar characterization of a gas-liquid flow microchip of TU/e, with two tailored mixer designs, is used to solve fundamental issues on hydrodynamics, and therefore, to achieve further design and operating optimization of that chip and the IMM device. Flow pattern maps are presented in a dimensionless fashion for further predictions on new fluidic systems for optimum single-channel multiphase operation. Bubble formation was investigated in the two types of mixers and pinch-off and hydrodynamic decay mechanisms are observed. The impact of these mechanisms on bubble size, bubble size distributions, and on the corresponding flow patterns, i.e., the type of mixer design, can be decisive for the flow pattern map and thus, may be used to alter flow pattern maps. The bubble sizes and their distribution were improved for the tailored designs, i.e., smaller and more regular bubbles were generated. Finally, the impact of multi-channel distribution for gas and liquid flow is demonstrated. Intermediate flow patterns such as slug-annular flow, also found for single-phase operation, and the simultaneous coexistence of flow regimes are presented, with the latter providing evidence of flow maldistribution.
Resumo:
It is known that the method used to mix the liquid monomer and powder of PMMA bone cement influences the quality of the cement that is used in total joint replacements. Mixing theory indicates that the interaction between the liquid monomer and the powder is affected by a number of parameters, such as cement viscosity and degree of agitation, with this knowledge utilized in the design of cement mixing devices. Therefore, the objectives of this study were to: (i) obtain information on the interaction of the liquid monomer and the powder in the case of an PMMA bone cement, (ii) show how this knowledge can be applied to the design of an automated cement mixing device, and (iii) compare the porosity, bending modulus, and bending strength of one commercially-available cement prepared using the automated mixer and prepared using a conventional mixer that is in current clinical use. Experimental data indicated that increasing the velocity and decreasing the viscosity of the systems produced cement that improved mechanical properties, which may contribute to better mechanical integrity and, hence, reduced tendency for aseptic loosening, of cemented hip implants.
Resumo:
A microfluidic device designed for electrochemical studies on a microliter scale has been utilized for the examination of impurity levels in ionic liquids (ILs). Halide impurities are common following IL synthesis, and this study demonstrates the ability to quantify low concentrations of halide in a range of ILs to levels of similar to 5 ppm, even in ILs not currently measurable using other methods such as ion chromatography. To validate the mixer device, the electrochemistry of ferrocene was also examined and compared with spectroscopic and bulk electrochemistry measurements. An automated
Resumo:
In this paper, we verify a new phase conjugating architecture suitable for deployment as (lie core building block in retrodirective antenna arrays, which can be scaled to any number of elements in a modular way without impacting on complexity. Our solution is based on a modified in-phase and quadrature modulator architecture, which completely resolves four major shortcomings of the conventional mixer-based approach currently used for the synthesis of phase conjugated energy derived from a sampled incoming wavefront. 1) The architecture presented removes the need for a local oscillator running at twice the RF signal frequency to be conjugated. 2) It maintains a constant transmit power even if receive power goes as low as -120 dBm. 3) All unwanted re-transmit signal products are suppressed by at least 40 dB. 4) The issue of poor RF-IF leakage prevalent in mixer-based phase-conjugation solutions is completely mitigated. The circuit has also been shown to have high conjugation accuracy (better than +/-1 degrees at -60-dBm input). Near theoretically perfect experimental monostatic and bistatic results are presented for a ten-element retrodirective array constructed using the new phase conjugation architecture.
Resumo:
A wide tuning range voltage controlled oscillator (VCO) with novel architecture is proposed in this work. The entire circuit consists of a VCO core, a summing circuit, a single-ended to differential (STD) converter and a buffer amplifier. The VCO core oscillates at half the desired frequency and the second harmonic of the VCO core is extracted by the summing circuit, which is then converted to a differential pair by the STD. The entire VCO circuit operates from 58.85 to 70.85 GHz with 20% frequency tuning range. The measured VCO gain is less than 1.6 GHz/V. The measured phase noise at 3 MHz offset is less than -78 dBc/Hz across the entire tuning range. The differential phase error of the output signals is measured by down converting the VCO output signals to low gigahertz frequency using an on-chip mixer. The measured differential phase error is less than 8°. The VCO circuit, which is constructed using 0.35 µm SiGe technology, occupies 770 × 550 µm2 die area and consumes 62 mA under 3.5 V supply.
Resumo:
Capillary hydrodynamics has three considerable distinctions from macrosystems: first, there is an increase in the ratio of the surface area of the phases to the volume that they occupy; second, a flow is characterized by small Reynolds numbers at which viscous forces predominate over inertial forces; and third, the microroughness and wettability of the wall of the channel exert a considerable influence on the flow pattern. In view of these differences, the correlations used for tubes with a larger diameter cannot be used to calculate the boundaries of the transitions between different flow regimes in microchannels. In the present review, an analysis of published data on a gas-liquid two-phase flow in capillaries of various shapes is given, which makes it possible to systematize the collected body of information. The specific features of the geometry of a mixer and an inlet section, the hydraulic diameter of a capillary, and the surface tension of a liquid exert the strongest influence on the position of the boundaries of two-phase flow regimes. Under conditions of the constant geometry of the mixer, the best agreement in the position of the boundaries of the transitions between different hydrodynamic regimes in capillaries is observed during the construction of maps of the regimes with the use of the Weber numbers for a gas and a liquid as coordinate axes.
Resumo:
An interdigital mixer - redispersion capillary assembly was applied to prevent the liquid-liquid bubbly flow coalescence in microreactors. The redispersion capillary consisted of 1 mm long and 0.25 mm inner-diameter constrictions placed every 0.50 m along the channel length. The system was tested on the phase transfer catalyzed esterification to produce benzyl benzoate. The application of constrictions to prevent coalescence resulted in a better reproducibility compared to a capillary without the constrictions. By controlling the total flow rate and the aqueous-to-organic ratio the bubbly flow surface-volume ratio could be increased up to 230 700 m(2)m(-3). Compared to the conventional phase transfer catalyzed esterification, the continuous operation in the interdigital-redispersion capillary assembly eliminated the use of solvents and bases, removing an energy intensive step of distillation, while increasing process safety.
Resumo:
Two equal batches of pig feed were prepared sequentially in a half-ton mixer. The first was prepared to contain 100-mu-g/g sulphadimidine and the second had not added sulphadimidine. The medicated batch was shown to have 97.2-mu-g/g and the flush 2-mu-g/g. From the conditions of the experiment it was suggested that sulphadimidine was preferentially retained in the mixer.
Resumo:
Design of small mixer impellers is not tailored for granulation as they are designed for a wide range of processes. The Kenwood KM070 was employed as a standard apparatus to undertake this investigation. Five different impeller designs were used, possessing different shapes and surface areas. The aim of this research was to evaluate the performances of these impellers to provide
guidance on the selection and design for the purposes of granulation. Lactose granules were produced using wet granulation with water as the binder.
The efficacy of respective granulates was measured by adding an optically
sensitive tracer.This was used to determine powder concentrations
within various regions of the granulator. It was found that impeller design influenced the homogeneity of the granules; and therefore can affect final product performance.
Resumo:
This paper shows a simple, yet highly effective, tracking phase locked loop circuit which has applications for self steered antenna arrays. The tracking PLL has been demonstrated to accurately phase track signal levels as low as -120 dBm, making it suitable for applications such as SATCOM ground terminals. The implementation is simple requiring a low Q voltage controlled oscillator, a downconverting mixer and a PLL circuit.
Resumo:
Small mixer impeller design is not tailored for granulation because impellers are intended for a wide range of processes. The aim of this research was to evaluate the performances of several impellers to provide guidance on the selection and design for the purposes of granulation. Lactose granules were produced using wet granulation with water as a binder. A Kenwood KM070 mixer was used as a standard apparatus and five impeller designs with different shapes and surface areas were used. The efficacy of granulate formation was measured by adding an optically sensitive tracer to determine variations in active ingredient content across random samples of granules from the same size classes. It was found that impeller design influenced the homogeneity of the granules and therefore can affect final product performance. The variation in active ingredient content across granules of differing size was also investigated. The results show that small granules were more potent than larger granules.