49 resultados para Desktop simulator

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the efficacy of a custom made wheelchair simulation in training children to use a powered wheelchair (PWC). Design: Randomised controlled trial employing the 4C/ID-model of learning. Twenty-eight typically developing children (13M, 15F; mean age 6 years, SD 6 months) were assessed on their operation of a PWC using a functional evaluation rating scale. Participants were randomly assigned to intervention (8x 30minute training sessions using a joystick operated wheelchair simulation) or control conditions (no task), and were re-assessed on their PWC use following the intervention phase. Additional data from the simulation on completion times, errors and total scores were recorded for the intervention group. Results: Analysis of variance showed a main effect of time, with planned comparisons revealing a statistically significant change in PWC use for the intervention (p = 0.022) but not the control condition. Whilst the intervention group showed greater improvement than the controls this did not reach statistical significance. Multiple regression analyses showed that gender was predictive of pre-test (p = 0.005) functional ability. Implications: A simulated wheelchair task appears to be effective in helping children learn to operate a PWC. Greater attention should be given to female learners who underperformed when compared to their male counterparts. This low cost intervention could be easily employed at home to reduce PWC training times in children with motor disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

<p>Research in the field of sports performance is constantly developing new technology to help extract meaningful data to aid in understanding in a multitude of areas such as improving technical or motor performance. Video playback has previously been extensively used for exploring anticipatory behaviour. However, when using such systems, perception is not active. This loses key information that only emerges from the dynamics of the action unfolding over time and the active perception of the observer. Virtual reality (VR) may be used to overcome such issues. This paper presents the architecture and initial implementation of a novel VR cricket simulator, utilising state of the art motion capture technology (21 Vicon cameras capturing kinematic profile of elite bowlers) and emerging VR technology (Intersense IS-900 tracking combined with Qualisys Motion capture cameras with visual display via Sony Head Mounted Display HMZ-T1), applied in a cricket scenario to examine varying components of decision and action for cricket batters. This provided an experience with a high level of presence allowing for a real-time egocentric view-point to be presented to participants. Cyclical user-testing was carried out, utilisng both qualitative and quantitative approaches, with users reporting a positive experience in use of the system.</p>

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Presented is a study that expands the body of knowledge on the effect of in-cycle speed fluctuations on performance of small engines. It uses the methods developed previously by Callahan, et al. (1) to examine a variety of two-stroke engines and one four-stroke engine. The two-stroke engines were: a high performance single-cylinder, a low performance single-cylinder, a high performance multi-cylinder, and a medium performance multi-cylinder. The four-stroke engine was a high performance single-cylinder unit. Each engine was modeled in Virtual Engines, which is a fully detailed one-dimensional thermodynamic engine simulator. Measured or predicted in-cycle speed data were input into the engine models. Predicted performance changes due to drivetrain effects are shown in each case, and conclusions are drawn from those results. The simulations for the high performance single-cylinder two-stroke engine predicted significant in-cycle crankshaft speed fluctuation amplitudes and significant changes in performance when the fluctuations were input into the engine model. This was validated experimentally on a firing test engine based on a Yamaha YZ250. The four-stroke engine showed significant changes in predicted performance compared to the prediction with zero speed fluctuation assumed in the model. Measured speed fluctuations from a firing Yamaha YZ400F engine were applied to the simulation in addition to data from a simple free mass model. Both methods predicted similar fluctuation profiles and changes in performance. It is shown that the gear reduction between the crankshaft and clutch allowed for this similar behavior. The multi-cylinder, high performance two-stroke engine also showed significant changes in performance, in this case depending on the firing configuration. The low output two-stroke engine simulation showed only a negligible change in performance in spite of high amplitude speed fluctuations. This was due to its flat torque versus speed characteristic. The medium performance multi-cylinder two-stroke engine also showed only a negligible change in performance, in this case due to a relatively high inertia rotating assembly and multiple cylinder firing events within the revolution. These smoothed the net torque pulsations and reduced the amplitude of the speed fluctuation itself.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mixed-mode simulation, where device simulation is embedded directly within a circuit simulator, is used for the first time to provide scaling guidelines to achieve optimal digital circuit performance for double gate SOI MOSFETs. This significant advance overcomes the lack of availability of SPICE model parameters. The sensitivity of the gate delay and on-off current ratio to each of the key geometric and technological parameters of the transistor is quantified. The impact of the source-drain doping profile on circuit performance is comprehensively investigated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and purpose: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation.Methods: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage.Results: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5+/-5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4+/-3.5% and normal tissue over-coverage of 25.4+/-4.2%.Conclusions: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and purpose: Currently, optimal use of virtual simulation for all treatment sites is not entirely clear. This study presents data to identify specific patient groups for whom conventional simulation may be completely eliminated and replaced by virtual simulation. Sampling and method: Two hundred and sixty patients were recruited from four treatment sites (head and neck, breast, pelvis, and thorax). Patients were randomly assigned to be treated using the usual treatment process involving conventional simulation, or a treatment process differing only in the replacement of conventional plan verification with virtual verification. Data were collected on set-up accuracy at verification, and the number of unsatisfactory verifications requiring a return to the conventional simulator. A micro-economic costing analysis was also undertaken, whereby data for each treatment process episode were also collected: number and grade of staff present, and the time for each treatment episode. Results: The study shows no statistically significant difference in the number of returns to the conventional simulator for each site and study arm. Image registration data show similar quality of verification for each study arm. The micro-costing data show no statistical difference between the virtual and conventional simulation processes. Conclusions: At our institution, virtual simulation including virtual verification for the sites investigated presents no disadvantage compared to conventional simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrical characteristics of various elements that can be used as spatial phase shifters in circularly polarised (CP) reflectarrays are contrasted. The elements investigated are; a single rotating dipole at 10.3 GHz; a multiple dipole at 18.2 GHz; a rotating stub at 2.8 GHz; and a periphery point short-circuited circular patch at 3.0 GHz. For each element type, results are presented for the reflection phase, polarisation purity and reflection loss. Where appropriate, experiments are performed using the waveguide simulator technique to validate the numerical EM simulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A pin diode-loaded active doubly periodic flat strip FSS is shown to act as a dynamic screen. It is shown that by means of d.c. bias control, we can utilize the screen in, (1) transmission mode as a dual band electromagnetic shutter, or with the inclusion of a ground plane in reflection mode, (is (2) it dual band refection canceller. (3) an amplitude shift keying (ASK) spatial modulator. The properties of the FSS are characterized using a specially designed parallel plate waveguide simulator that permits normal incidence excitation of the FSS under test. (C) 2009 Wiley Periodicals. Inc. Microwave Opt Technol Lett 51: 2059-2061, 2009; Published online in Wiley Inter-Science (www. interscience.wiley.com). DOI 10.1002/mop.24547

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modeling of on-body propagation channels is of paramount importance to those wishing to evaluate radio channel performance for wearable devices in body area networks (BANs). Difficulties in modeling arise due to the highly variable channel conditions related to changes in the user's state and local environment. This study characterizes these influences by using time-series analysis to examine and model signal characteristics for on-body radio channels in user stationary and mobile scenarios in four different locations: anechoic chamber, open office area, hallway, and outdoor environment. Autocorrelation and cross-correlation functions are reported and shown to be dependent on body state and surroundings. Autoregressive (AR) transfer functions are used to perform time-series analysis and develop models for fading in various on-body links. Due to the non-Gaussian nature of the logarithmically transformed observed signal envelope in the majority of mobile user states, a simple method for reproducing the failing based on lognormal and Nakagami statistics is proposed. The validity of the AR models is evaluated using hypothesis testing, which is based on the Ljung-Box statistic, and the estimated distributional parameters of the simulator output compared with those from experimental results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stand-alone virtual environments (VEs) using haptic devices have proved useful for assembly/disassembly simulation of mechanical components. Nowadays, collaborative haptic virtual environments (CHVEs) are also emerging. A new peer-to-peer collaborative haptic assembly simulator (CHAS) has been developed whereby two users can simultaneously carry out assembly tasks using haptic devices. Two major challenges have been addressed: virtual scene synchronization (consistency) and the provision of a reliable and effective haptic feedback. A consistency-maintenance scheme has been designed to solve the challenge of achieving consistency. Results show that consistency is guaranteed. Furthermore, a force-smoothing algorithm has been developed which is shown to improve the quality of force feedback under adverse network conditions. A range of laboratory experiments and several real trials between Labein (Spain) and Queenâs University Belfast (Northern Ireland) have verified that CHAS can provide an adequate haptic interaction when both users perform remote assemblies (assembly of one userâs object with an object grasped by the other user). Moreover, when collisions between grasped objects occur (dependent collisions), the haptic feedback usually provides satisfactory haptic perception. Based on a qualitative study, it is shown that the haptic feedback obtained during remote assemblies with dependent collisions can continue to improve the sense of co-presence between users with regard to only visual feedback.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a practical algorithm for the simulation of interactive deformation in a 3D polygonal mesh model. The algorithm combines the conventional simulation of deformation using a spring-mass-damping model, solved by explicit numerical integration, with a set of heuristics to describe certain features of the transient behaviour, to increase the speed and stability of solution. In particular, this algorithm was designed to be used in the simulation of synthetic environments where it is necessary to model realistically, in real time, the effect on non-rigid surfaces being touched, pushed, pulled or squashed. Such objects can be solid or hollow, and have plastic, elastic or fabric-like properties. The algorithm is presented in an integrated form including collision detection and adaptive refinement so that it may be used in a self-contained way as part of a simulation loop to include human interface devices that capture data and render a realistic stereoscopic image in real time. The algorithm is designed to be used with polygonal mesh models representing complex topology, such as the human anatomy in a virtual-surgery training simulator. The paper evaluates the model behaviour qualitatively and then concludes with some examples of the use of the algorithm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wear particle accumulation is one of the main contributors to osteolysis and implant failure in hip replacements. Altered kinematics produce significant differences in wear rates of hip replacements in simulator studies due to varying degrees of multidirectional motion. Gait analysis data from 153 hip-replacement patients 10-years post-operation were used to model two- and three-dimensional wear paths for each patient. Wear paths were quantified in two dimensions using aspect ratios and in three dimensions using the surface areas of the wear paths, with wear-path surface area correlating poorly with aspect ratio. The average aspect ratio of the patients wear paths was 3.97 (standard deviation ¼ 1.38), ranging from 2.13 to 10.86. Sixty percent of patients displayed aspect ratios between 2.50 and 3.99. However, 13% of patients displayed wear paths with aspect ratios 45.5, which indicates reduced multidirectional motion. The majority of total hip replacement (THR) patients display gait kinematics which produce multidirectional wear paths, but a significant minority display more linear paths.