44 resultados para Computer-assisted instruction--Evaluation.

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computer-assisted pathological immunohistochemistry scoring is more time-effective than conventional scoring, but provides no analytical advantage

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Chronic kidney disease (CKD) and hypertension are global public health problems associated with considerable morbidity, premature mortality and attendant healthcare costs. Previous studies have highlighted that non-invasive examination of the retinal microcirculation can detect microvascular pathology that is associated with systemic disorders of the circulatory system such as hypertension. We examined the associations between retinal vessel caliber (RVC) and fractal dimension (DF), with both hypertension and CKD in elderly Irish nuns.

Methods: Data from 1233 participants in the cross-sectional observational Irish Nun Eye Study (INES) were assessed from digital photographs with a standardized protocol using computer-assisted software. Multivariate regression analyses were used to assess associations with hypertension and CKD, with adjustment for age, body mass index (BMI), refraction, fellow eye RVC, smoking, alcohol consumption, ischemic heart disease (IHD), cerebrovascular accident (CVA), diabetes and medication use.

Results: In total, 1122 (91%) participants (mean age: 76.3 [range: 56-100] years) had gradable retinal images of sufficient quality for blood vessel assessment. Hypertension was significantly associated with a narrower central retinal arteriolar equivalent (CRAE) in a fully adjusted analysis (P = 0.002; effect size= -2.16 μm; 95% confidence intervals [CI]: -3.51, -0.81 μm). No significant associations between other retinal vascular parameters and hypertension or between any retinal vascular parameters and CKD were found.

Conclusions: Individuals with hypertension have significantly narrower retinal arterioles which may afford an earlier opportunity for tailored prevention and treatment options to optimize the structure and function of the microvasculature, providing additional clinical utility. No significant associations between retinal vascular parameters and CKD were detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract This study evaluates the reliability of self-assessment as a measure of computer competence. This evaluation is carried out in response to recent research which has employed self-reported ratings as the sole indicator of students’ computer competence. To evaluate the reliability of self-assessed computer competence, the scores achieved by students in self-assessed computer competence tests are compared with scores achieved in objective tests. The results reveal a statistically significantly over-estimation of computer competence among the students surveyed. Furthermore, reported pre-university computer experience in terms of home and school use and formal IT education does not affect this result. The findings call into question the validity of using self-assessment as a measure of computer competence. More generally, the study also provides an up-to-date picture of self-reported computer usage and IT experience among pre-university students from New Zealand and South-east Asia and contrasts these findings with those from previous research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces an automated computer- assisted system for the diagnosis of cervical intraepithelial neoplasia (CIN) using ultra-large cervical histological digital slides. The system contains two parts: the segmentation of squamous epithelium and the diagnosis of CIN. For the segmentation, to reduce processing time, a multiresolution method is developed. The squamous epithelium layer is first segmented at a low (2X) resolution. The boundaries are further fine tuned at a higher (20X) resolution. The block-based segmentation method uses robust texture feature vectors in combination with support vector machines (SVMs) to perform classification. Medical rules are finally applied. In testing, segmentation using 31 digital slides achieves 94.25% accuracy. For the diagnosis of CIN, changes in nuclei structure and morphology along lines perpendicular to the main axis of the squamous epithelium are quantified and classified. Using multi-category SVM, perpendicular lines are classified into Normal, CIN I, CIN II, and CIN III. The robustness of the system in term of regional diagnosis is measured against pathologists' diagnoses and inter-observer variability between two pathologists is considered. Initial results suggest that the system has potential as a tool both to assist in pathologists' diagnoses, and in training.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ensuring that all graduates are able to exploit new technologies is a primary goal of all UK universities and a variety of assumptions have underpinned policies designed to promote this goal, This paper explores some of these assumptions through the findings of a. longitudinal study involving a cohort of over 800 university students. The study adopted a student perspective to examine the factors affecting their use of computers over a three year period. Unsurprisingly, the results indicated that situational factors (e.g. access, training and time) influence the extent to which students use computers, but a disparity was found in the importance attributed to these factors by the academic staff, who focused on the needs of their department, and by the students, who focused on their individual needs. Results suggest that increased attention to a student perspective may lead to improved strategic planning in students' use of computers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Side-channel attacks (SCA) threaten electronic cryptographic devices and can be carried out by monitoring the physical characteristics of security circuits. Differential Power Analysis (DPA) is one the most widely studied side-channel attacks. Numerous countermeasure techniques, such as Random Delay Insertion (RDI), have been proposed to reduce the risk of DPA attacks against cryptographic devices. The RDI technique was first proposed for microprocessors but it was shown to be unsuccessful when implemented on smartcards as it was vulnerable to a variant of the DPA attack known as the Sliding-Window DPA attack.Previous research by the authors investigated the use of the RDI countermeasure for Field Programmable Gate Array (FPGA) based cryptographic devices. A split-RDI technique wasproposed to improve the security of the RDI countermeasure. A set of critical parameters wasalso proposed that could be utilized in the design stage to optimize a security algorithm designwith RDI in terms of area, speed and power. The authors also showed that RDI is an efficientcountermeasure technique on FPGA in comparison to other countermeasures.In this article, a new RDI logic design is proposed that can be used to cost-efficiently implementRDI on FPGA devices. Sliding-Window DPA and realignment attacks, which were shown to beeffective against RDI implemented on smartcard devices, are performed on the improved RDIFPGA implementation. We demonstrate that these attacks are unsuccessful and we also proposea realignment technique that can be used to demonstrate the weakness of RDI implementations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Timely and individualized feedback on coursework is desirable from a student perspective as it facilitates formative development and encourages reflective learning practice. Faculty however are faced with a significant and potentially time consuming challenge when teaching larger cohorts if they are to provide feedback which is timely, individualized and detailed. Additionally, for subjects which assess non-traditional submissions, such as Computer-Aided-Design (CAD), the methods for assessment and feedback tend not to be so well developed or optimized. Issues can also arise over the consistency of the feedback provided. Evaluations of Computer-Assisted feedback in other disciplines (Denton et al, 2008), (Croft et al, 2001) have shown students prefer this method of feedback to traditional “red pen” marking and also that such methods can be more time efficient for faculty.
Herein, approaches are described which make use of technology and additional software tools to speed up, simplify and automate assessment and the provision of feedback for large cohorts of first and second year engineering students studying modules where CAD files are submitted electronically. A range of automated methods are described and compared with more “manual” approaches. Specifically one method uses an application programming interface (API) to interrogate SolidWorks models and extract information into an Excel spreadsheet, which is then used to automatically send feedback emails. Another method describes the use of audio recordings made during model interrogation which reduces the amount of time while increasing the level of detail provided as feedback.
Limitations found with these methods and problems encountered are discussed along with a quantified assessment of time saving efficiencies made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To investigate effects of cryopreservation on sperm motility and DNA integrity. Design: Pre-cryopreservation and post-cryopreservation analysis of motility and DNA integrity of semen and prepared sperm samples. Setting: A hospital andrology laboratory. Patient(s): Forty men attending the Regional Fertility Centre, Belfast, Northern Ireland. Intervention(s): Each sample was divided, and an aliquot was frozen unprepared. Remaining aliquots were prepared by Percoll density centrifugation (95.0:47.5) or direct swim-up procedure and divided into aliquots to allow direct comparison of fresh and frozen semen and prepared sperm (frozen with or without the addition of seminal plasma) from the same ejaculate. Samples were frozen by static-phase vapor cooling and being plunged into liquid nitrogen. Thawing was carried out at room temperature. Main Outcome Measure(s): Sperm DNA integrity was determined using a modified alkaline single cell gel electrophoresis (comet) assay, and motility was determined using computer-assisted semen analysis. Result(s): Sperm frozen unprepared in seminal fluid appeared more resistant to freezing damage than frozen prepared sperm. Further improvements can be achieved by selecting out the subpopulation of sperm with best motility and DNA integrity and freezing these sperm in seminal plasma, making this the optimal procedure. Conclusion(s): Freezing sperm in seminal plasma improves postthaw motility and DNA integrity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: to investigate the effects of tetrahydrocannabinol; THC on human sperm function in vitro. Design: laboratory analysis of sperm motility with and without exposure to THC using computer assisted semen analysis (CASA) and acrosome reaction by fluoroscein isothiocyanate labelled peanut agglutinin (FITC-PNA) staining. Setting: An ART unit in a tertiary medical centre. Patients: semen was obtained from 78 men attending the Regional Fertility Centre, Belfast. Interventions: Sperm were divided into 90% (the best fertilizing potential used in assisted conception) and 45% (the poorer subpopulation) fractions by density centrifugation and incubated with, or without (controls), tetrahydrocannabinol (THC) at concentrations equivalent to therapeutic (0.032�?�¯?�?�­M) and recreational (4.8 and 0.32�?�¯?�?�­M) plasma levels, at 37�?�¯?�?�°C for 3 hours. Main outcome measures: Sperm motility, spontaneous and induced acrosome reactions Results: There was a dose-dependent decrease in percentage progressive motility (-21% at 4.8�??�?�µM, p0.05) in the 90% fraction. The 45% fraction showed a greater decrease in percentage progressive motility (-56% at 4.8�??�?�µM, p=0.011; -23% at 0.32�??�?�µM, p= 0.039; and -28% at 0.032�??�?�µM, p=0.004). A decrease in the straight line velocity; VSL (-10%) and the average path velocity; VAP (-10%) were also observed in the 90% fraction. A significant inhibition (-15% at 4.8�??�?�µM, p=0.04) in spontaneous acrosome reaction was observed in the 90% fraction. The 45% fraction showed a more marked inhibition [-35% (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: to determine if sildenafil citrate; a cyclic monophosphate specific type 5 phosphodiesterase inhibitor, influences sperm motility or the acrosome reaction. Design: laboratory analysis of sperm motility after exposure to sildenafil citrate using computer assisted semen analysis (CASA) and acrosome reaction by fluoroscein isothiocyanate labelled peanut agglutinin (FITC-PNA) staining. Setting: An ART unit Patients: 57 male patients Interventions: Sperm were divided into 90% (the best fertilizing potential used in assisted conception) and 45% (the poorer subpopulation) fractions by density centrifugation and incubated with sildenafil citrate ( 0.67uM) at 37ï?°C for up to 180 minutes. Main outcome measures: both the numbers and velocity of progressively motile sperm were significantly increased by sildenafil citrate between 15 and 135 minutes. Further, samples revealed that these effects were consistent in the 90% and 45% subpopulations of sperm. In both subpopulations, sildenafil also caused a significant increase in the proportion of acrosome reacted sperm - 22.1% compared with 11.8% in the control group of the good quality fraction (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computer-assisted topology predictions are widely used to build low-resolution structural models of integral membrane proteins (IMPs). Experimental validation of these models by traditional methods is labor intensive and requires modifications that might alter the IMP native conformation. This work employs oxidative labeling coupled with mass spectrometry (MS) as a validation tool for computer-generated topology models. ·OH exposure introduces oxidative modifications in solvent-accessible regions, whereas buried segments (e.g., transmembrane helices) are non-oxidizable. The Escherichia coli protein WaaL (O-antigen ligase) is predicted to have 12 transmembrane helices and a large extramembrane domain (Pérez et al., Mol. Microbiol. 2008, 70, 1424). Tryptic digestion and LC-MS/MS were used to map the oxidative labeling behavior of WaaL. Met and Cys exhibit high intrinsic reactivities with ·OH, making them sensitive probes for solvent accessibility assays. Overall, the oxidation pattern of these residues is consistent with the originally proposed WaaL topology. One residue (M151), however, undergoes partial oxidation despite being predicted to reside within a transmembrane helix. Using an improved computer algorithm, a slightly modified topology model was generated that places M151 closer to the membrane interface. On the basis of the labeling data, it is concluded that the refined model more accurately reflects the actual topology of WaaL. We propose that the combination of oxidative labeling and MS represents a useful strategy for assessing the accuracy of IMP topology predictions, supplementing data obtained in traditional biochemical assays. In the future, it might be possible to incorporate oxidative labeling data directly as constraints in topology prediction algorithms.