145 resultados para Cobalt-chromium alloys

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Medical geology research has recognised a number of potentially toxic elements (PTEs), such as arsenic, cobalt, chromium, copper, nickel, lead, vanadium, uranium and zinc, known to influence human disease by their respective deficiency or toxicity. As the impact of infectious diseases has decreased and the population ages, so cancer has become the most common cause of death in developed countries including Northern Ireland. This research explores the relationship between environmental exposure to potentially toxic elements in soil and cancer disease data across Northern Ireland. The incidence of twelve different cancer types (lung, stomach, leukaemia, oesophagus, colorectal, bladder, kidney, breast, mesothelioma, melanoma and non melanoma(NM) both basal and squamous, were examined in the form of twenty-five coded datasets comprising aggregates over the 12 year period from 1993 to 2006. A local modelling technique,geographically weighted regression (GWR) is usedto explore the relationship between environmental exposure and cancer disease data. The results show comparisons of the geographical incidence of certain cancers (stomach and NM squamous skin cancer) in relation to concentrations of certain PTEs (arsenic levels in soils and radon were identified). Findings from the research have implications for regional human health risk assessments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper brings together and analyzes recent work based on the interpretation of the electrochemical measurements made on a modified micro-abrasion-corrosion tester used in several research programmes. These programmes investigated the role of abradant size, test solution pH in abrasion-corrosion of biomaterials, the abrasion-corrosion performance of sintered and thermally sprayed tungsten carbide surfaces under downhole drilling environments and the abrasion-corrosion of UNS S32205 duplex stainless steel. Various abrasion tests were conducted under two-body grooving, three-body rolling and mixed grooving-rolling abrasion conditions, with and without abrasives, on cast F75 cobalt-chromium-molybdenum (CoCrMo) alloy in simulated body fluids, 2205 in chloride containing solutions as well as sprayed and sintered tungsten carbide surfaces in simulated downhole fluids. Pre- and post-test inspections based on optical and scanning electron microscopy analysis are used to help interpret the electrochemical response and current noise measurements made in situ during micro-abrasion-corrosion tests. The complex wear and corrosion mechanisms and their dependence on the microstructure and surface composition as a function of the pH, abrasive concentration, size and type are detailed and linked to the electrochemical signals. The electrochemical versus mechanical processes are plotted for different test parameters and this new approach is used to interpret tribo-corrosion test data to give greater insights into different tribo-corrosion systems. Thus new approaches to interpreting in-situ electrochemical responses to surfaces under different abrasive wear rates, different abrasives and liquid environments (pH and NaCl levels) are made. This representation is directly related to the mechano-electrochemical processes on the surface and avoids quantification of numerous synergistic, antagonistic and additive terms associated with repeat experiments. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to compare two different tooth replacement strategies for partially dentate older patients; namely functionally orientated treatment according to the principles of the shortened dental arch (SDA) and conventional treatment using removable partial dentures (RPDs) using a randomised controlled clinical trial. The primary outcome measure for this study was impact on oral health-related quality of life (OHRQoL) measured using the short form of the oral health impact profile (OHIP-14).

METHODS: Patients aged 65 years and older were randomly allocated to two different treatment groups: the RPD group and the SDA group. For the RPD group each patient was restored to complete arches with cobalt-chromium RPDs used to replace missing teeth. For the SDA group, patients were restored to a premolar occlusion of 10 occluding pairs of natural and replacement teeth using resin bonded bridgework (RBB). OHRQoL was measured using the OHIP-14 questionnaire administered at baseline, 1 month, 6 months and 12 months after treatment intervention.

RESULTS: In total, 89 patients completed the RCT: 44 from the RPD group and 45 from the SDA group. Analysis using a mixed model of covariance (ANCOVA) illustrated that treatment according to the SDA concept resulted in significantly better mean OHIP-14 scores compared with RPD treatment (p<0.05). This result was replicated in both treatment centres used in the study.

CONCLUSIONS: In terms of impact on OHRQoL, treatment based on the SDA concept achieved significantly better results than that based on RPDs 12 months after treatment intervention (trial registration no. ISRCTN26302774).

CLINICAL SIGNIFICANCE: Functionally orientated treatment delivery resulted in significantly better outcomes compared to removable dentures in terms of impact on OHRQoL.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A swing-lock denture is useful in partially dentate patients where the configuration of the remaining teeth means that either the retention or stability available for a conventional removable partial denture is compromised. Such removable prostheses can also prove to be extremely useful when providing prosthodontic rehabilitation following surgical resection of oral cancer. A 20 year-old patient was referred to the Restorative Department of Cork University Dental Hospital following segmental mandibulectomy to treat a calicifying epithelial odontogenic tumour (Pindborg Tumour). Initial treatment using a conventional lower partial denture failed. This paper outlines the successfully rehabilitation using a lower Cobalt-Chromium swing-lock partial denture.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To compare caries incidence following two different tooth replacement strategies for partially dentate older patients; namely functionally orientated treatment according to the principles of the Shortened Dental Arch (SDA) and conventional treatment using Removable Partial Dentures (RPDs). Method:A randomised controlled clinical trial (RCT) was conducted of partially dentate patients aged 65 years and older. Patients were randomly allocated to two different treatment groups: the RPD group and the SDA group. Each member of the RPD group was restored to complete arches with cobalt-chromium RPDs used to replace missing teeth. Patients in the SDA group were restored to a shortened arch of 10 occluding pairs of natural and replacement teeth using adhesive bridgework. All of the operative treatment was completed by a single operator. Caries incidence was measured over a 2-year period following treatment intervention and recorded using the International Caries and Detection System (ICDAS). Result:In total, 89 patients completed the RCT (45 SDAs and 44 RPDs). Patients in the RPD group recorded a significantly higher incidence of new carious lesions (p<0.001) and recurrent carious lesions (p<0.001) compared to the SDA group. A mixed model of covariance (ANCOVA) revealed that treatment group (p<0.001) and co-morbidity (p<0.001) were significant predictors of caries incidence. Conclusion:Two years after provision of prosthodontic treatment there was a significantly higher incidence of new and recurrent caries lesions in subjects provided with RPDs compared with SDA treatment. This will have a significant impact on the ongoing maintenance costs for these two treatment groups.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aims: This study aimed to gain insight into patient’s perceptions of natural tooth loss and explored their experiences of oral rehabilitation according to a functionally orientated approach (SDA) and Removable Partial Dentures (RPD).
Study Design: For this qualitative study, a purposive sample of 15 partially dentate older patients
were recruited from Cork Dental School and Hospital. These patients had previously participated in a randomised controlled clinical trial (RCT) where they were provided with either SDA treatment using adhesive bridgework or provided with Cobalt Chromium framework RPDs. In- depth interviews were undertaken and thematic analysis was utilised to interpret the data.
Results: The findings of this study indicated strong satisfaction with SDA treatment. Patients referred to the ease in which they adapted to the adhesive prostheses as they were “lightweight”, “neat” and “fixed”. Irrespective of treatment option, patients indicated that they felt
their new prostheses were durable and an improvement on previous treatments. Most patients indicated that, previous to the RCT, they had not attended a general dentist for a number of years and only then for acute issues. They had concerns that treatment which was provided to them as part of the RCT would not be available to them in primary care. Interestingly, although they do not want their condition to dis-improve, if their prostheses failed they stated that they would not seek alternative treatment but would revert back
to adopting previous coping mechanisms.
Conclusion: This study illustrates that partially dentate older patients were very satisfied with oral rehabilitation according to a functionally orientated approach. Unfortunately they did not believe that this treatment would currently be made available to them in a primary care setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe a self-consistent magnetic tight-binding theory based in an expansion of the Hohenberg-Kohn density functional to second order, about a non-spin-polarized reference density. We show how a first order expansion about a density having a trial input magnetic moment leads to a fixed moment model. We employ a simple set of tight-binding parameters that accurately describes electronic structure and energetics, and show these to be transferable between first row transition metals and their alloys. We make a number of calculations of the electronic structure of dilute Cr impurities in Fe, which we compare with results using the local spin density approximation. The fixed moment model provides a powerful means for interpreting complex magnetic configurations in alloys; using this approach, we are able to advance a simple and readily understood explanation for the observed anomaly in the enthalpy of mixing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution synchrotron X-ray diffraction was used to study the phase transformations in titanium alloys. Three titanium alloys were investigated: Ti-6Al-4V, Ti-6Al-2Sn-4Zr-2Mo-0.08Si and beta21s. Both room and high temperature measurements were performed. The room temperature experiments were performed to study the structure of the alloys after different heat treatments, namely as received (AR), furnace cooling (FC), water quenching (WQ) and water quenching followed by ageing. The alpha, alpha', alpha'' and beta phases were observed in different combinations depending on the heat treatment conditions and the alloy studied. A multicomponent hexagonal close packed (hcp) alpha phase, with different c and the same a lattice parameters, was detected in Ti-6Al-4V after FC. High temperature synchrotron X-ray diffraction was used for 'in situ' study of the transformations on the sample surface at elevated temperatures. The results were used to trace the kinetics of surface oxidation and the concurrent phase transformations taking place under different conditions. The influence of the temperature and oxygen content on the lattice parameters of the alpha phase was derived and new data obtained on the coefficients of thermal expansion in the different directions of the hcp alpha phase, for Ti-6Al-4V and Ti-6Al-2Sn-4Zr-2Mo-0.08Si.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel CVD WSi2 technology with low series and contact resistance in SiGe HBTs was achieved. Specific contact resistance to Si1-xGex with 0