57 resultados para Cantilever slab

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Engineers have proposed the idea that there may be some arching action present in bridge deck cantilever overhangs stiffened along their longitudinal free edge, via a traffic barrier, subjected to a wheel load. This paper includes the details of a full-scale corrosion-free bridge deck with cantilever overhangs stiffened along their longitudinal free edge by a traffic barrier wall that has been constructed and tested under static and fatigue wheel loads at the University of Manitoba. It also reviews experimental test results and postulates various discussions that suggest the presence of arching-action in cantilever slab overhangs. Test results indicated static ultimate load capacities significantly greater than the ultimate capacity if the mode of failure and behavior of the cantilever overhang was completely flexural. These early results confirm and indicate the presence of arching-action resulting in a significant break-through in cantilever behavior when subjected to a wheel load. The theory to account for this arching-action is not yet developed and further research should be conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The random displacement of magnetic field lines in the presence of magnetic turbulence in plasmas is investigated from first principles. A two-component (slab/two-dimensional composite) model for the turbulence spectrum is employes. An analytical investigation of the asymptotic behavior of the field-line mean square displacement (FL-MSD) is carried out. It is shown that the magnetic field lines behave superdifusively for every large values of the position variable z, since the FL-MSD sigma varies as sigma similar to z(4/3). An intermediate diffusive regime may also possible exist for finite values of z under conditions which are explicitly determined in terms of the intrinsic turbulent plasma parameters. The superdiffusie asymptotic result is confirmed numerically via an iterative algorithm. The relevance to previous resuslts is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of non-uniform target illumination on the soft X-ray lasing output intensity of the J=2-1 Ne-like Ge transitions as a function of length was investigated. As the degree of nonunifonnity increased with length the Ne-like Ge 23.2 and 23.6 nm J=2-1 transitions did not show exponentiation of output intensity. Using an experimentally measured gain-intensity scaling relationship these results were modelled and good qualitative agreement obtained. The model indicates that for Ge targets which are non-uniformly illuminated, even with peak to valley ratios of up to 3 efficient operation can be achieved at between 2-3x threshold intensity. Further studies of the effect of increasing the separation between the two targets of a double target geometry are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gain coefficient of the strongest 3p --> 3s, J = 2 --> 1 lasing transition at 23.6 nm in the Ne-like Ge collisional excitation scheme has been measured, using the fundamental wavelength from a Nd:glass laser (1.06-mu-m), for a range of incident intensities on massive stripe targets up to 2.2 cm in length. From a threshold incident laser intensity of approximately 6 x 10(12) W/cm2, the gain coefficient rises to approximately 4.5 cm-1 for an irradiation intensity of approximately 2.5 x 10(13) W/cm2, tending towards still higher gain coefficients at higher incident intensities. For targets of maximum length, a gain-length product gL almost-equal-to 10 was reached with a resultant output power at 23.6 nm estimated to be at the approximately kW level. The beam divergence decreased with length to a minimum of approximately 7 mrad but no significant trend in beam pointing with plasma length was observed. From the trend in the gain coefficient, it appears that for a fixed energy laser irradiating a approximately 100-mu-m wide slab targets, an incident intensity of I(i) approximately 1.2 x 10(13) W/cm2 represents an optimum working level, assuming that plasma length is not limited by refractive effects. In addition to the usual valence electron excited 3p --> 3s transitions, the gain coefficient for the core excited 1s(2)2s2p(6)3d --> 1s(2)2s2p(6)3p transition at 19.9 nm has been measured to be approximately 1.5 cm-1 for an incident irradiance of approximately 2.5 x 10(13) W/cm2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour and ultimate load capacity of laterally-restrained reinforced concrete slabs can be considerably enhanced by the development of arching or compressive membrane action. This paper presents a simple method for predicting the enhanced ultimate load capacity of laterally-restrained slab strips. The method is based on deformation theory and utilizes an elastic-plastic stress-strain criterion for concrete. The loads carried by bending and arching action are calculated separately and then added to give the total ultimate load capacity. A simple equivalent strip approach, based on a three-hinged arch analogy, allows for the degree of lateral restraint. The method of prediction has been validated by correlation with a wide range of test results from various sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Fonualei Spreading Center affords an excellent opportunity to evaluate geochemical changes with increasing depth to the slab in the Lau back-arc basin. We present H2O and CO2 concentrations and Sr, Nd, Pb, Hf and U-Th-Ra isotope data for selected glasses as well as new Hf isotope data from boninites and seamounts to the north of the Tonga arc. The Pb and Hf isotope data are used to show that mantle flow is oriented to the southwest and that the tear in the northern end of the slab may not extend east as far as the boninite locality. Along the Fonualei Spreading Center, key geochemical parameters change smoothly with increasing distance from the arc front and increasing slab surface temperatures. The latter may range from 720 to 866 degrees C, based on decreasing H2O/Ce ratios. Consistent with experimental data, the geochemical trends are interpreted to reflect changes in the amount and composition of wet pelite melts or super-critical fluids and aqueous fluids derived from the slab. With one exception, all of the lavas preserve both U-238 excesses and Ra-226 excesses. We suggest that lavas from the Fonualei Spreading Center and Valu Fa Ridge are dominated by fluid-fluxed melting whereas those from the East and Central Lau Spreading Centers, where slab surface temperatures exceed similar to 850-900 degrees C, are largely derived through decompression. A similar observation is found for the Manus and East Scotia back-arc basins and may reflect the expiry of a key phase such as lawsonite in the subducted basaltic crust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis for the cause of fracture failure of a cantilever steel sign post damaged by wind has been carried out. An unusual cause of failure has been identified, which is the subject of this paper. Microscopy and microanalysis of the fracture surface showed that the failure was due to pre-existing cracks, from the fabrication of the post. This conclusion was reached after detecting and analysing a galvanised layer on the fracture surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study on strengthening prestressed concrete (PC) hollow-core slabs was conducted. Nine PC hollow-core slabs were tested, including three unstrengthened reference slabs and six slabs strengthened with bamboo plates. The results show that compared with unreinforced slabs, the cracking loads of PC hollow-core slabs strengthened with bamboo plates increase by 5% to 96% (with an average of 41%), the loads at allowable deflection increase by 8% to 76% (with an average of 35%), and the ultimate loads increase by 83% to 184% (with an average of 123%), respectively. All the degrees of improvement in the crack load, allowable load and ultimate load increase with the increase in the thickness and width of the bamboo plates. With the increase in the loads, the strain distribution along the height of the strengthened slabs at the mid-span basically remains a plan-assumption. With the increase in the thickness and width of the bamboo plates, both the bamboo tensile strain on the tensile face and the concrete compressive strain on the compression face of the strengthened slabs decrease under the same load level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of short and long term service load tests were undertaken on the sixth floor of the full-scale, seven storey, reinforced concrete building at the Large Building Test Facility of the Building Research Establishment at Cardington. By using internally strain gauged reinforcing bars cast into an internal and external floor bay during the construction process it was possible to gain a detailed record of slab strains resulting from the application of several arrangements of test loads. Short term tests were conducted in December 1998 and long term monitoring then ensued until April 2001. This paper describes the test programmes and presents results to indicate slab behaviour for the various loading regimes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The corrosion of reinforcement in bridge deck slabs has been the cause of major deterioration and high costs in repair and maintenance.This problem could be overcome by reducing the amount of reinforcement and/or altering the location.This is possible because, in addition to the strength provided by the reinforcement, bridge deck slabs have an inherent strength due to the in-plane arching forces set up as a result of restraint provided by the slab boundary conditions. This is known as arching action or Compressive Membrane Action (CMA). It has been recognised for some time that laterally restrained slabs exhibit strengths far in excess of those predicted by most design codes but the phenomenon has not been recognised by the majority of bridge design engineers. This paper presents the results of laboratory tests on fifteen reinforced concrete slab strips typical of a bridge deck slab and compares them to predicted strengths using the current codes and CMA theory. The tests showed that the strength of laterally restrained slabs is sensitive to both the degree of external lateral restraint and the concrete compressive strength.The tests particularly highlighted the benefits in strength obtained from very high strength concrete slabs. The theory extends the existing knowledge of CMA in slabs with concrete compressive strengths up to 100 N/mm[2] and promotes more economical and durable bridge deck construction by utilising the benefits of high strength concrete.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The deterioration of infrastructure, such as bridges, has been one of the major challenges facing both the designers and the owners of such utilities. Sustainable development and a climate of increasing commercialism has led to a requirement for more accurate means of structural analysis. Bridge assessment is one area where this is particularly relevant. It has been known for some time that bridge deck slabs have inherent enhanced strength due to the presence of arching or compressive membrane action (CMA) but only in recent years has there been some acceptance of a rational treatment of this phenomenon for design and assessment purposes. To use the benefits of arching action, this paper presents the results of tests carried out on a reinforced-concrete beam and slab bridge in Northern Ireland that incorporated novel reinforcement type and position. The research was aimed at extending previous laboratory tests on 1/3scale bridge deck edge panels. The measured crack widths and deflections have been compared with the current code requirements.