22 resultados para AVERAGE POWER

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a new dual-gas multi-jet HHG source which can be perfectly controlled via phasematching of the long and short trajectory contributions and is applicable for high average power driver laser systems. © 2011 Optical Society of America.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Power back-off performances of a new variant power-combining Class-E amplifier under different amplitude-modulation schemes such as continuous wave (CW), envelope elimination and restoration (EER), envelope tracking (ET) and outphasing are for the first time investigated in this study. Finite DC-feed inductances rather than massive RF chokes as used in the classic single-ended Class-E power amplifier (PA) resulted from the approximate yet effective frequency-domain circuit analysis provide the wherewithal to increase modulation bandwidth up to 80% higher than the classic single-ended Class-E PA. This increased modulation bandwidth is required for the linearity improvement in the EER/ET transmitters. The modified output load network of the power-combining Class-E amplifier adopting three-harmonic terminations technique relaxes the design specifications for the additional filtering block typically required at the output stage of the transmitter chain. Qualitative agreements between simulation and measurement results for all four schemes were achieved where the ET technique was proven superior to the other schemes. When the PA is used within the ET scheme, an increase of average drain efficiency of as high as 40% with respect to the CW excitation was obtained for a multi-carrier input signal with 12 dB peak-to-average power ratio. © 2011 The Institution of Engineering and Technology.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Power back-off performances of the modified power-combining Class-E amplifier under different amplitudemodulation schemes such as envelope elimination and restoration (EER) and envelope tracking (ET) are experimentally assessed in this paper. The modified output load network adopting three-harmonic terminations technique eliminates the need for additional lossy filtering section in the transmitter chain. Small dc-feed inductances rather than massive RF chokes as in the classic Class-E amplifier are used so as to increase the modulation bandwidth and therefore improve the linearity of the EER transmitter. High efficiency over a wide dynamic range using amplitude modulation through drain-voltage control (EER) was achieved and this agrees well with the Class-E theoretical prediction. When the PA was used within the ET scheme, an increase of average drain efficiency of as high as 40% with respect to the CW excitation was obtained for a multi-carrier input signal with 12dB peak-to-average power ratio. © 2011 Institut fur Mikrowellen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A detailed theoretical analysis has been carried out to study efficient heating due to microwaves for one-dimensional (1D) oil–water emulsion samples placed on various ceramic, metallic (reflective) and ceramic–metallic composite supports. Two typical emulsion systems are considered such as oil-in-water (o/w) and water-in-oil (w/o). A preliminary study has been carried out via average power vs emulsion thickness diagram to estimate microwave power absorption within emulsion samples for various cases. The maxima in average power, also termed as ‘resonances’, are observed for specific emulsion thicknesses and the two consecutive resonances of significant magnitudes are termed as R1 and R2 modes. For both o/w and w/o emulsions, it is observed that microwave power absorption is enhanced in presence of metallic and composite supports during both R1 and R2 modes. The efficient heating strategies characterized by ‘large heating rates’ with ‘minimal thermal runaway’ i.e. uniform temperature distributions within the sample have been assessed for each type of emulsion. Based on the detailed spatial distributions of power and temperature for various cases, SiC-metallic composite support may be recommended as an optimal heating strategy for o/w samples with higher oil fractions (0.45) whereas metallic and Alumina-metallic composite supports may be favored for samples with smaller oil fractions (=0.3) during R1 mode. For w/o samples, SiC-metallic composite support may be suitable heating strategy for all ranges of water fractions during R1 mode. During R2 mode, metallic and Alumina-metallic composite supports are favored for both o/w and w/o emulsion samples. Current study recommends the efficient way to use microwaves in a single mode waveguide and the heating strategy can be suitably extended for heating of any other emulsions for which dielectric properties are easily measurable or available in the literature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Orthogonal frequency division multiplexing (OFDM) requires an expensive linear amplifier at the transmitter due to its high peak-to-average power ratio (PAPR). Single carrier with cyclic prefix (SC-CP) is a closely related transmission scheme that possesses most of the benefits of OFDM but does not have the PAPR problem. Although in a multipath environment, SC-CP is very robust to frequency-selective fading, it is sensitive to the time-selective fading characteristics of the wireless channel that disturbs the orthogonality of the channel matrix (CM) and increases the computational complexity of the receiver. In this paper, we propose a time-domain low-complexity iterative algorithm to compensate for the effects of time selectivity of the channel that exploits the sparsity present in the channel convolution matrix. Simulation results show the superior performance of the proposed algorithm over the standard linear minimum mean-square error (L-MMSE) equalizer for SC-CP.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Practical demonstration of the operational advantages gained through the use of a co-operating retrodirective array (RDA) basestation and Van Atta node arrangements is discussed. The system exploits a number of inherent RDA features to provide analogue real time multifunctional operation at low physical complexity. An active dual-conversion four element RDA is used as the power distribution source (basestation) while simultaneously achieving a receive sensitivity level of ??109 dBm and 3 dB automatic beam steering angle of ??45??. When mobile units are each equipped with a semi-passive four element Van Atta array, it is shown mobile device orientation issues are mitigated and optimal energy transfer can occur because of automatic beam formation resulting from retrodirective self-pointing action. We show that operation in multipath rich environments with or without line of sight acts to reduce average power density limits in the operating volume with high energy density occurring at mobile nodes sites only. The system described can be used as a full duplex ASK communications link, or, as a means for remote node charging by wireless means, thereby enhancing deployment opportunities between unstabilised moving platforms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A linear hydrodynamic model is used to assess the sensitivity of the performance of a wave energy converter (WEC) array to control parameters. It is found that WEC arrays have a much smaller tolerance to imprecision of the control parameters than isolated WECs and that the increase in power capture of WEC arrays is only achieved with larger amplitudes of motion of the individual WECs. The WEC array radiation pattern is found to provide useful insight into the array hydrodynamics. The linear hydrodynamic model is used, together with the wave climate at the European Marine Energy Centre (EMEC), to assess the maximum annual average power capture of a WEC array. It is found that the maximum annual average power capture is significantly reduced compared to the maximum power capture for regular waves and that the optimum array configuration is also significantly modified. It is concluded that the optimum configuration of a WEC array will be as much influenced by factors such as mooring layout, device access and power smoothing as it is by the theoretical optimum hydrodynamic configuration. © 2009 Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper we present a design methodology for algorithm/architecture co-design of a voltage-scalable, process variation aware motion estimator based on significance driven computation. The fundamental premise of our approach lies in the fact that all computations are not equally significant in shaping the output response of video systems. We use a statistical technique to intelligently identify these significant/not-so-significant computations at the algorithmic level and subsequently change the underlying architecture such that the significant computations are computed in an error free manner under voltage over-scaling. Furthermore, our design includes an adaptive quality compensation (AQC) block which "tunes" the algorithm and architecture depending on the magnitude of voltage over-scaling and severity of process variations. Simulation results show average power savings of similar to 33% for the proposed architecture when compared to conventional implementation in the 90 nm CMOS technology. The maximum output quality loss in terms of Peak Signal to Noise Ratio (PSNR) was similar to 1 dB without incurring any throughput penalty.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Using the Otto (prism-air gap-sample) configuration p-polarized light of wavelength 632.8 nm has been coupled with greater than 80% efficiency to surface plasmons on the aluminium electrode of silicon-silicon dioxide-aluminium structures. The results show that if the average power per unit area dissipated on the metal film exceeds approximately 1 mW mm-2, then the coupling gap and thus the characteristics of the surface plasmon resonance are noticeably altered. In modelling the optical response of such systems the inclusion of both a non-uniform air coupling gap and a thin cermet layer at the aluminium surface may be necessary.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To model the possible impact of using average-power intraocular lenses (IOLs) and evaluate the postoperative refractive error in patients having cataract surgery in rural China.SETTING: Rural Guangdong, China.METHODS: Patients having cataract surgery by local surgeons were examined and visual function was assessed 10 to 14 months after surgery. Subjective refraction at near and distance was performed bilaterally by an ophthalmologist. Patients had a target refraction of -0.50 diopter (D) based on ocular biometry.RESULTS: Of the 313 eligible patients, 242 (77%) could be contacted and 176 (74% of contacted patients, 56% overall) were examined. Examined patients had a mean age of 69.4 +/- 10.5 years. Of the 211 operated eyes, 73.2% were within +/-1.0 D of the target refraction after surgery. The best presenting distance vision was in patients within +/-1.0 D of plano and the best presenting near vision, in those with mild myopia (<-1.0 D to > or =2.0 D) (P= .005). However, patients with hyperopia (>+1.0 D) reported significantly better adjusted visual function than those with emmetropia or myopia (<-1.0 D). When the predicted use of an average-power IOL (median +21.5 D) was modeled, predicted visual acuity was significantly reduced (P= .001); however, predicted visual function was not significantly altered (P>.3).CONCLUSIONS: Accurate selection of postoperative refractive error was achieved by local surgeons in this rural area. Based on visual function results, aiming for mild postoperative myopia may not be suitable in this setting. Implanting average-power IOLs significantly reduced postoperative presenting vision, but not visual function.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From the instantaneous efficiency plot, it is observed that the conventional 2-stage Doherty power amplifier (DPA) with high upper power dynamic range (>12 dB) suffers from a substantial dip in the middle of the upper power regime, thus reducing the average efficiency. In this study, an envelope-tracking-based DPA is proposed in order to minimise this dip by adjusting the drain bias voltage of the auxiliary amplifier of the DPA proportional to the input power level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A central question in community ecology is how the number of trophic links relates to community species richness. For simple dynamical food-web models, link density (the ratio of links to species) is bounded from above as the number of species increases; but empirical data suggest that it increases without bounds. We found a new empirical upper bound on link density in large marine communities with emphasis on fish and squid, using novel methods that avoid known sources of bias in traditional approaches. Bounds are expressed in terms of the diet-partitioning function (DPF): the average number of resources contributing more than a fraction f to a consumer's diet, as a function of f. All observed DPF follow a functional form closely related to a power law, with power-law exponents indepen- dent of species richness at the measurement accuracy. Results imply universal upper bounds on link density across the oceans. However, the inherently scale-free nature of power-law diet partitioning suggests that the DPF itself is a better defined characterization of network structure than link density.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In ultra-low data rate wireless sensor networks (WSNs) waking up just to listen to a beacon every superframe can be a major waste of energy. This study introduces MedMAC, a medium access protocol for ultra-low data rate WSNs that achieves significant energy efficiency through a novel synchronisation mechanism. The new draft IEEE 802.15.6 standard for body area networks includes a sub-class of applications such as medical implantable devices and long-term micro miniature sensors with ultra-low power requirements. It will be desirable for these devices to have 10 years or more of operation between battery changes, or to have average current requirements matched to energy harvesting technology. Simulation results are presented to show that the MedMAC allows nodes to maintain synchronisation to the network while sleeping through many beacons with a significant increase in energy efficiency during periods of particularly low data transfer. Results from a comparative analysis of MedMAC and IEEE 802.15.6 MAC show that MedMAC has superior efficiency with energy savings of between 25 and 87 for the presented scenarios. © 2011 The Institution of Engineering and Technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of continuous sonication and presonication on the kinetics of oxidative dissolution of ruthenium dioxide hydrate by bromate ions under acidic conditions are reported. Compared with unsonicated and presonicated dispersions the overall rate of dissolution of continuously sonicated dispersions is significantly greater due to a reduction in the average particle size and, hence, an increase in the specific surface area. Powder dispersions subjected to continuous ultrasound and presonication exhibit an initial induction period in their corrosion kinetics; the length of this induction period increases with increasing presonication. This corrosion feature is retained in the dissolution kinetics of powder samples which have been subjected to pre-ultrasound, but which are then stirred during the dissolution process. It is believed that this apparent permanent change in the nature of the powder particles is due to the ultrasound induced formation of a very thin layer of a largely unreactive form of ruthenium dioxide (possibly due to partial dehydration) on the surface of the powder particles. A kinetic scheme, based on this model, is used to account for the observed kinetics of dissolution of RuO2 . xH2O which have been subjected to both continuous sonication and presonication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the envelope-tracking technique is exploited to boost average efficiency of the newly introduced broadband Inverse Class-E power amplifier. A 2.26 GHz - 20.5 dBm - 3 V power amplifier was designed, constructed, and measured. For a multi-carrier input signal with 10 dB peak-to-average ratio, the average PAE was increased from 5.7% to 54.5%. © 2008 IEEE.