221 resultados para 091209 Polymers and Plastics

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aromatic monomers can be polymerised using the chloroaluminate room temperature melt obtained by mixing 1:2 ratio of cetyl pyridinium chloride and anhydrous aluminium chloride miscible in all proportions with organic solvents as an electrolyte. The chloroaluminate (AlCl4-) anion generated in this melt having a tetrahedral symmetry with equal bond lengths and bond angles is the dopant to stabilize macrocation generated near the vicinity of anode to yield better conducting and better ordered electronically conducting free standing polymer film. In this communication, we discuss the polymers derived from benzene and pyrrole and their characterization by various techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During free surface moulding processes such as thermoforming and blow moulding heated polymer materials are subjected to rapid biaxial deformation as they are drawn into the shape of a mould. In the development of process simulations it is therefore essential to be able to accurately measure and model this behaviour. Conventional uniaxial test methods are generally inadequate for this purpose and this has led to the development of specialised biaxial test rigs. In this paper the results of several programmes of biaxial tests conducted at Queen’s University are presented and discussed. These have included tests on high impact polystyrene (HIPS), polypropylene (PP) and aPET, and the work has involved a wide variety of experimental conditions. In all cases the results clearly demonstrate the unique characteristics of materials when subjected to biaxial deformation. PP draws the highest stresses and it is the most temperature sensitive of the materials. aPET is initially easier to form but exhibits strain hardening at higher strains. This behaviour is increased with increasing strain rate but at very high strain rates these effects are increasingly mollified by adiabatic heating. Both aPET and PP (to a lesser degree) draw much higher stresses in sequential stretching showing that this behaviour must be considered in process simulations. HIPS showed none of these effects and it is the easiest material to deform.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using fluorescence microscopy, DSC and DMTA we have explored blends of a bitumen with a styrene-butadiene-styrene (SBS) block copolymer, and with blends of the bitumen with SBS and one or two homopolymers - a polystyrene and a poly(cis-butadiene). The SBS polymer was progressively replaced with quantities of the homopolymers both together in the proportions found in the block copolymer and then by each homopolymer separately. At low temperatures the blends are all softer than the bitumen itself, so the polymers plasticise the bitumen-rich phase, and above 50°C the blends' stiffness (E') falls below a plateau only when a critical proportion of the block copolymer has been replaced with the two homopolymers: this supports the idea of an extensive network created by the polystyrene-rich spherical microphases that is effective even when the polystyrene microphases have melted. In one polymer blend the stiffness rose as the temperature was raised above 100°C, suggesting the development of a mesophase based upon polybutadiene plus asphaltenes, in another E' was enhanced and E" remained constant as the temperature rose above 70°C, perhaps for a similar reason; in some loss process appeared and the stiffness fell as temperature rose; but in others a good part of the SBS was replaced by either polystyrene or polybutadiene without changing the appearance of a rubbery plateau, that is, without a diminution of the mechanical properties of the soft matter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acoustic pulse reflectometry is used to reconstruct the internal bore profile of trumpet and cornet leadpipe. The method distinguishes between radii differences as small as 0.03 mm, and has since been used by various UK-based brass instrument manufacturers as a diagnostic tool to detect defects that are significant enough to acoustically alter performance.