215 resultados para Rapid Technologien


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The emergence of programmable logic devices as processing platforms for digital signal processing applications poses challenges concerning rapid implementation and high level optimization of algorithms on these platforms. This paper describes Abhainn, a rapid implementation methodology and toolsuite for translating an algorithmic expression of the system to a working implementation on a heterogeneous multiprocessor/field programmable gate array platform, or a standalone system on programmable chip solution. Two particular focuses for Abhainn are the automated but configurable realisation of inter-processor communuication fabrics, and the establishment of novel dedicated hardware component design methodologies allowing algorithm level transformation for system optimization. This paper outlines the approaches employed in both these particular instances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Screening for Helicobacter pylori in dyspeptic patients may improve selectivity for gastroscopy. Rapid serological tests based on ELISA technique are cheap, readily available and simple to use in the clinical setting. However local evaluation is essential in order to validate these techniques. Fifty-six dyspeptic patients (aged less than 45 yr) had a rapid serological test (Helisal) performed prior to gastroscopy. At gastroscopy H. pylori status was assessed using culture and histology. The Helisal sensitivity was 80 per cent, specificity 82 per cent. Screening patients with the Helisal test would have missed 6 patients with peptic ulcer disease and 2 with oesophagitis. The Helisal test did not perform satisfactorily as a screening test in selection of patients for gastroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the basis of previous experimental studies we postulated that individuals who were phenotypically good hydroxylators but poor sulphoxidisers would be susceptible to chlorpromazine jaundice. Sulphoxidation capacity was assessed in 12 subjects with a history of chlorpromazine jaundice, using S-carboxymethyl-L-cysteine as an in vivo probe. Following an oral dose of 750 mg, unchanged compound and sulphoxide metabolites were measured in urine. All 12 subjects (100%) were shown to be poor sulphoxidisers compared to 22% of normal controls (P less than 0.001) and 23.8% of liver disease controls (P less than 0.001). No subjects with a history of chlorpromazine jaundice had an impaired hydroxylation capacity as assessed by recovery of 4-hydroxydebrisoquine in urine following oral debrisoquine. The results support the hypothesis and demonstrate an inherent metabolic basis of susceptibility to chlorpromazine jaundice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In view of both the delay in obtaining identification by conventional methods following blood-culture positivity in patients with candidaemia and the close relationship between species and fluconazole (FLC) susceptibility, early speciation of positive blood cultures has the potential to influence therapeutic decisions. The aim was to develop a rapid test to differentiate FLC-resistant from FLC-sensitive Candida species. Three TaqMan-based real-time PCR assays were developed to identify up to six Candida species directly from BacT/Alert blood-culture bottles that showed yeast cells on Gram staining at the time of initial positivity. Target sequences in the rRNA gene complex were amplified, using a consensus two-step PCR protocol, to identify Candida albicans, Candida parapsilosis, Candida tropicalis, Candida dubliniensis, Candida glabrata and Candida krusei; these are the most commonly encountered Candida species in blood cultures. The first four of these (the characteristically FLC-sensitive group) were identified in a single reaction tube using one fluorescent TaqMan probe targeting 1 8S rRNA sequences conserved in the four species. The FLC-resistant species C. krusei and C. glabrata were detected in two further reactions, each with species-specific probes. This method was validated with clinical specimens (blood cultures) positive for yeast (n=33 sets) and the results were 100% concordant with those of phenotypic identification carried out concomitantly. The reported assay significantly reduces the time required to identify the presence of C. glabrata and C. krusei in comparison with a conventional phenotypic method, from ~72 to

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prototype fluorescent based biosensor has been developed for the antibody based detection of food related contaminants. Its performance was characterised and showed a typical antibody binding signal of 200-2000 mV, a short term noise of 9.1 mV, and baseline slope of -0.016 mV/s over 4 h. Bulk signal detection repeatability (n=23) and reproducibility (n=3) were less than 2.4%CV. The biosensor detection unit was evaluated using two food related model systems proving its ability to monitor both binding using commercial products and inhibition through the development of an assay. This assay development potential was evaluated by observing the biosensor's performance whilst appraising several labelled antibody and glass slide configurations. The molecular interaction between biotin and an anti-biotin antibody was shown to be inhibited by 41% due to the presence of biotin in a sample. A food toxin (domoic acid) calibration curve was produced, with %CVs ranging from 2.7 to 7.8%, and a midpoint of approximately 17 ng/ml with further optimisation possible. The ultimate aim of this study was to demonstrate the working principles of this innovative biosensor as a potential portable tool with the opportunity of interchangeable assays. The biosensor design is applicable for the requirements of routine food contaminant analysis, with respect to performance, functionality and cost. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the occupational hazards within the tanning industry caused by contaminated dust. A qualitative assessment of the risk of human exposure to dust was made throughout a commercial Kenyan tannery. Using this information, high-risk points in the processing line were identified and dust sampling regimes developed. An optical set-up using microscopy and digital imaging techniques was used to determine dust particle numbers and size distributions. The results showed that chemical handling was the most hazardous (12 mg m(-3)). A Monte Carlo method was used to estimate the concentration of the dust in the air throughout the tannery during an 8 h working day. This showed that the high-risk area of the tannery was associated with mean concentrations of dust greater than the UK Statutory Instrument 2002 No. 2677. stipulated limits (exceeding 10 mg m(-3) (Inhalable dust limits) and 4 mg m(-3) (Respirable dust limits). This therefore has implications in terms of provision of personal protective equipment (PPE) to the tannery workers for the mitigation of occupational risk.