150 resultados para Technique d’échantillonnage de réseau
Resumo:
PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.
PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.
RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.
CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.
Resumo:
A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.
Resumo:
We present a step-by-step guide of a refined magnetoseismological technique for plasma diagnostics in the Sun’s corona. Recently developed MHD wave theory which models a coronal loop as an expanding magnetic flux tube with an arbitrary longitudinal plasma density profile is applied to TRACE observations of fast kink
oscillations. The theory predicts that using the observed ratio of the first overtone and fundamental mode to predict the plasma density scale height and not taking account of loop expansion will lead to an overestimation of scale height. For the first time, the size of this correction is quantified directly from observation and for the particular case study presented here, it is found that the overestimation is approximately by a factor of 2.
Resumo:
This paper reports the detailed description and validation of a fully automated, computer controlled analytical method to spatially probe the gas composition and thermal characteristics in packed bed systems. As an exemplar, we have examined a heterogeneously catalysed gas phase reaction within the bed of a powdered oxide supported metal catalyst. The design of the gas sampling and the temperature recording systems are disclosed. A stationary capillary with holes drilled in its wall and a moveable reactor coupled with a mass spectrometer are used to enable sampling and analysis. This method has been designed to limit the invasiveness of the probe on the reactor by using the smallest combination of thermocouple and capillary which can be employed practically. An 80 mu m (O.D.) thermocouple has been inserted in a 250 mu m (O.D.) capillary. The thermocouple is aligned with the sampling holes to enable both the gas composition and temperature profiles to be simultaneously measured at equivalent spatially resolved positions. This analysis technique has been validated by studying CO oxidation over a 1% Pt/Al2O3 catalyst and the spatial resolution profiles of chemical species concentrations and temperature as a function of the axial position within the catalyst bed are reported.
Resumo:
Biosignal measurement and processing is increasingly being deployed in ambulatory situations particularly in connected health applications. Such an environment dramatically increases the likelihood of artifacts which can occlude features of interest and reduce the quality of information available in the signal. If multichannel recordings are available for a given signal source, then there are currently a considerable range of methods which can suppress or in some cases remove the distorting effect of such artifacts. There are, however, considerably fewer techniques available if only a single-channel measurement is available and yet single-channel measurements are important where minimal instrumentation complexity is required. This paper describes a novel artifact removal technique for use in such a context. The technique known as ensemble empirical mode decomposition with canonical correlation analysis (EEMD-CCA) is capable of operating on single-channel measurements. The EEMD technique is first used to decompose the single-channel signal into a multidimensional signal. The CCA technique is then employed to isolate the artifact components from the underlying signal using second-order statistics. The new technique is tested against the currently available wavelet denoising and EEMD-ICA techniques using both electroencephalography and functional near-infrared spectroscopy data and is shown to produce significantly improved results. © 1964-2012 IEEE.
Resumo:
Stellar activity, such as starspots, can induce radial velocity (RV) variations that can mask or even mimic the RV signature of orbiting exoplanets. For this reason RV exoplanet surveys have been unsuccessful when searching for planets around young, active stars and are therefore failing to explore an important regime which can help to reveal how planets form and migrate. This paper describes a new technique to remove spot signatures from the stellar line-profiles of moderately rotating, active stars (v sin i ranging from 10 to 50 km s(-1)). By doing so it allows planetary RV signals to be uncovered. We used simulated models of a G5V type star with differing dark spots on its surface along with archive data of the known active star HD 49933 to validate our method. The results showed that starspots could be effectively cleaned from the line-profiles so that the stellar RV jitter was reduced by more than 80 per cent. Applying this procedure to the same models and HD 49933 data, but with fake planets injected, enabled the effective removal of starspots so that Jupiter mass planets on short orbital periods were successfully recovered. These results show that this approach can be useful in the search for hot-Jupiter planets that orbit around young, active stars with a v sin i of similar to 10-50 km/s.
Resumo:
An experimental system, based upon UV and IR laser desorption, has been constructed to enable the production and characterization of neutral biomolecular targets. These targets are to be used for interaction experiments investigating radiation-induced damage to DNA. The viability of the laser-desorption techniques of MALDI (matrix-assisted laser-desorption ionization), SALDI (surface-assisted laser-desorption ionization) and DIOS (desorption/ionization on silicon), for production of these gas targets is discussed in the present paper. Fluorescent dye tagging and LIF (laser-induced fluorescence) imaging has been used to characterize the biomolecular plumes, revealing their spatial density profiles and temporal evolution. © The Authors Journal compilation. © 2009 Biochemical Society.
Resumo:
The diabetic dog represents an excellent model for use in many aspects of diabetic research. The present paper describes, in detail, a reproducible experimental protocol for the successful induction of chemical diabetes in beagles using a combination of the 2 pancreatic beta-cell cytoxic agents alloxan and streptozotocin.
Resumo:
Pretensioned concrete members are designed and manufactured by using at least two materials: concrete and prestressing reinforcement. Also, two main stages must be considered: prestress transfer and member loading. Hence, the behavior of these members depends strongly on the reinforcement-to-concrete bond performance and prestress losses. In this paper, a testing technique to measure the specific parameters related with the involved phenomena is presented. The testing technique is based on the analysis of series of specimens varying in embedment length to simulate several cross sections at only one end of a pretensioned concrete member. Each specimen is characterized by means of the sequential release of the prestress transfer (detensioning) and the pull-out (loading) operation. The test provides data on prestressing force, transmission length (initial and long-term), anchorage length (without and with slip), reinforcement slips, bond stresses, longitudinal concrete strains, concrete modulus of elasticity, and prestress losses (instantaneous and time-dependent).