158 resultados para Denture, Partial, Fixed
Resumo:
A new method to spatially probe heterogeneous catalysed reactions within a packed bed of catalyst has been developed. The spatial resolution is achieved using a stationary perforated capillary coupled to a mass spectrometer while the catalyst bed is moved. The oxidation of CO promoted by H-2 over a Pd catalyst has been used to demonstrate the technique.
Resumo:
Persistence of the asymmetrical tonic neck reflex (ATNR) was examined in children with partial hearing (aged 6–12 years). Core literacy skills were also assessed. Three groups of children were selected from three schools with special units for children with partial hearing. All children completed an upright ATNR test protocol and standardized tests of reading and spelling. Children with partial hearing had significant levels of ATNR persistence, and significant reading and spelling difficulties. The findings suggest that persistence of an early sub-cortical reflex system may be associated with some of the motor and cognitive difficulties experienced by children with partial hearing.
Resumo:
This paper introduces the paired comparison model as a suitable approach for the analysis of partially ranked data. For example, the Inglehart index, collected in international social surveys to examine shifts in post-materialistic values, generates such data on a set of attitude items. However, current analysis methods have failed to account for the complex shifts in individual item values, or to incorporate subject covariates. The paired comparison model is thus developed to allow for covariate subject effects at the individual level, and a reparameterization allows the inclusion of smooth non-linear effects of continuous covariates. The Inglehart index collected in the 1993 International Social Science Programme survey is analysed, and complex non-linear changes of item values with age, level of education and religion are identified. The model proposed provides a powerful tool for social scientists.
Resumo:
This paper elaborates on the ergodic capacity of fixed-gain amplify-and-forward (AF) dual-hop systems, which have recently attracted considerable research and industry interest. In particular, two novel capacity bounds that allow for fast and efficient computation and apply for nonidentically distributed hops are derived. More importantly, they are generic since they apply to a wide range of popular fading channel models. Specifically, the proposed upper bound applies to Nakagami-m, Weibull, and generalized-K fading channels, whereas the proposed lower bound is more general and applies to Rician fading channels. Moreover, it is explicitly demonstrated that the proposed lower and upper bounds become asymptotically exact in the high signal-to-noise ratio (SNR) regime. Based on our analytical expressions and numerical results, we gain valuable insights into the impact of model parameters on the capacity of fixed-gain AF dual-hop relaying systems. © 2011 IEEE.
Resumo:
Purpose
– The purpose of this paper is to investigate the performance of natural Jordanian zeolite tuff to remove ammonia from aqueous solutions using a laboratory batch method and fixed-bed column apparatus. Equilibrium data were fitted to Langmuir and Freundlich models.
Design/methodology/approach
– Column experiments were conducted in packed bed column. The used apparatus consisted of a bench-mounted glass column of 2.5 cm inside diameter and 100 cm height (column volume = 490 cm3). The column was packed with a certain amount of zeolite to give the desired bed height. The feeding solution was supplied from a 30 liter plastic container at the beginning of each experiment and fed to the column down-flow through a glass flow meter having a working range of 10-280ml/min.
Findings
– Ammonium ion exchange by natural Jordanian zeolite data were fitted by Langmuir and Freundlich isotherms. Continuous sorption of ammonium ions by natural Jordanian zeolite tuff has proven to be effective in decreasing concentrations ranging from 15-50 mg NH4-N/L down to levels below 1 mg/l. Breakthrough time increased by increasing the bed depth as well as decreasing zeolite particle size, solution flow-rate, initial NH4+ concentration and pH. Sorption of ammonium by the zeolite under the tested conditions gave the sorption capacity of 28 mg NH4-N/L at 20°C, and 32 mg NH4-N/L at 30°C.
Originality/value
– This research investigates the performance of natural Jordanian zeolite tuff to remove ammonia from aqueous solutions using a laboratory batch method and fixed-bed column apparatus. The equilibrium data of the sorption of Ammonia were plotted by using the Langmuir and Freundlich isotherms, then the experimental data were compared to the predictions of the above equilibrium isotherm models. It is clear that the NH4+ ion exchange data fitted better with Langmuir isotherm than with Freundlich model and gave an adequate correlation coefficient value.
Resumo:
A continuous cell-line has been shown to be adaptable to preparation of supernatants containing lymphokine activities. Separation and partial purification of migration inhibiting, colony stimulating and interferon activities from such preparations has been achieved by the use of density gradient iso-electric focusing.
Resumo:
The localisation and distribution of the cytoskeletal protein tubulin in the adult liver fluke Fasciola hepatica have been determined by an indirect immunofluorescence technique using a monoclonal antibody raised against beta-tubulin. Tubulin was demonstrated in the tegumental syncytium and in the tegumental cell bodies and their cytoplasmic connections with the surface syncytium. Immunostaining was also evident in the nerve fibres innervating sensory receptors in the tegument, in the nerve plexus innervating the sub-tegumental musculature and in the cytoplasmic extensions of the nurse cells within the vitelline follicle. Immunoblotting of whole fluke fractions produced a single band corresponding to a molecule of approximately 54 kDa in size. This figure corresponds with previous data obtained on tubulin from other helminth and eukaryotic sources.
Resumo:
The joint fluids of 37 patients with rheumatoid arthritis, eight patients with traumatic injuries to their joints, two patients with Reiter's syndrome and three patients with psoriatic arthritis were tested for the presence of B cell colony stimulating activity (B cell CSA). B cell CSA was found in all of the joint fluids from the patients with rheumatoid arthritis but in none of the joint fluids from patients with traumatic injuries to their joints or in the joint fluids from the patients with Reiter's syndrome. A trace of B cell CSA was found in the joint fluid of one of the three patients with psoriatic arthritis. There was a positive correlation (r = 0.796) between the amount of rheumatoid factor present in the joint fluids and the titre of B cell CSA. This correlation was highly significant (P less than 0.001). The B cell CSA was localized to component(s) with molecular weight ranges 115-129 kD and 64-72 kD and an isoelectric point of 6.8. Its activity was sensitive to reduction with 2-mercaptoethanol and to the oxidising action of potassium periodate.
Resumo:
The increasing penetration of wind generation on the Island of Ireland has been accompanied by close investigation of low-frequency periodic pulsations contained within the active power flow from different wind farms. A primary concern is excitation of existing low-frequency oscillation modes already present on the system, particularly the 0.75 Hz mode as a consequence of the interconnected Northern and Southern power system networks. Recently grid code requirements on the Northern Ireland power system have been updated stipulating that wind farms connected after 2005 must be able to control the magnitude of oscillations in the range of 0.25 - 1.75 Hz to within 1% of the wind farm's registered output. In order to determine whether wind farm low-frequency oscillations have a negative effect (excite other modes) or possibly a positive impact (damping of existing modes) on the power system, the oscillations at the point of connection must be measured and characterised. Using time - frequency methods, research presented in this paper has been conducted to extract signal features from measured low-frequency active power pulsations produced by wind farms to determine the effective composition of possible oscillatory modes which may have a detrimental effect on system dynamic stability. The paper proposes a combined wavelet-Prony method to extract modal components and determine damping factors. The method is exemplified using real data obtained from wind farm measurements.
Resumo:
This paper studies the impact of tower shadow effect on the power output of a fixed-speed wind farm. A data acquisition unit was placed at a wind farm in Northern Ireland which consists of ten fixed-speed wind turbines. The recording equipment logged the wind farmpsilas electrical data, which was time stamped using the global positioning network. Video footage of the wind farm was recorded and from it the blade angle of each turbine was determined with respect to time. Using the blade angle data and the wind farmpsilas power output, studies where performed to ascertain the extent of tower shadow effect on power fluctuation. This paper presents evidence that suggests that tower shadow effect has a significant impact on power fluctuation and that this effect is increased due to the synchronising of turbine blades around the tower region.
Resumo:
This study presents a model based on partial least squares (PLS) regression for dynamic line rating (DLR). The model has been verified using data from field measurements, lab tests and outdoor experiments. Outdoor experimentation has been conducted both to verify the model predicted DLR and also to provide training data not available from field measurements, mainly heavily loaded conditions. The proposed model, unlike the direct measurement based DLR techniques, enables prediction of line rating for periods ahead of time whenever a reliable weather forecast is available. The PLS approach yields a very simple statistical model that accurately captures the physical performance of the conductor within a given environment without requiring a predetermination of parameters as required by many physical modelling techniques. Accuracy of the PLS model has been tested by predicting the conductor temperature for measurement sets other than those used for training. Being a linear model, it is straightforward to estimate the conductor ampacity for a set of predicted weather parameters. The PLS estimated ampacity has proven its accuracy through an outdoor experiment on a piece of the line conductor in real weather conditions.