104 resultados para Time resolved emission spectra
Resumo:
We present the discovery of four new transiting hot jupiters, detected mainly from SuperWASP-North and SOPHIE observations. These new planets, WASP-52b, WASP-58b, WASP-59b, and WASP-60b, have orbital periods ranging from 1.7 to 7.9 days, masses between 0.46 and 0.94 M_Jup, and radii between 0.73 and 1.49 R_Jup. Their G1 to K5 dwarf host stars have V magnitudes in the range 11.7-13.0. The depths of the transits are between 0.6 and 2.7%, depending on the target. With their large radii, WASP-52b and 58b are new cases of low-density, inflated planets, whereas WASP-59b is likely to have a large, dense core. WASP-60 shows shallow transits. In the case of WASP-52 we also detected the Rossiter-McLaughlin anomaly via time-resolved spectroscopy of a transit. We measured the sky-projected obliquity lambda = 24 (+17/-9) degrees, indicating that WASP-52b orbits in the same direction as its host star is rotating and that this prograde orbit is slightly misaligned with the stellar equator. These four new planetary systems increase our statistics on hot jupiters, and provide new targets for follow-up studies.
Resumo:
Overdense plasmas are usually opaque to laser light. However, when the light is of sufficient intensity to drive electrons in the plasma to near light speeds, the plasma becomes transparent. This process—known as relativistic transparency—takes just a tenth of a picosecond. Yet all studies of relativistic transparency so far have been restricted to measurements collected over timescales much longer than this, limiting our understanding of the dynamics of this process. Here we present time-resolved electric field measurements (with a temporal resolution of ~ 50 fs) of the light, initially reflected from, and subsequently transmitted through, an expanding overdense plasma. Our result provides insight into the dynamics of the transparent-overdense regime of relativistic plasmas, which should be useful in the development of laser-driven particle accelerators, X-ray sources and techniques for controlling the shape and contrast of intense laser pulses.
Resumo:
Using benzene hydrogenation over Pt/SiO2 as an industrially-relevant example, we show that state-of-the-art neutron total scattering methods spanning a wide Q-range now permit relevant time-resolved catalytic chemistry to be probed directly in situ within the pore of the catalyst. The method gives access to the reaction rates on both nanometric and atomic length scales, whilst simultaneously providing an atomistic structural viewpoint on the reaction mechanism itself.
Resumo:
If recurrent novae are progenitors of Type Ia supernovae, their white dwarfs must have masses close to the Chandrasekhar limit. The most reliable means of determining white dwarf masses in recurrent novae is dynamically, via radial-velocity and rotational-broadening measurements of the companion star. Such measurements require the system to be both eclipsing and to show absorption features from the secondary star. Prior to the work reported here, the only dynamical mass estimate of a recurrent nova was for U Sco, which has a white dwarf mass of 1.55 +/- 0.24 Msolar (Thoroughgood et al. 2001). We present new time-resolved, intermediate-resolution spectroscopy of the eclipsing recurrent nova CI Aquilae (CI Aql) during quiescence. We find the mass of the white dwarf to be 1.00 +/- 0.14 Msolar and the mass of the secondary star to be 2.32 +/- 0.19 Msolar. We estimate the radius of the secondary to be 2.07 +/- 0.06 Rsolar, implying that it is a slightly-evolved early A-type star. The high mass ratio of q = 2.35 +/- 0.24 and the high secondary-star mass implies that the mass transfer occurs on a thermal timescale. We suggest that CI Aql is rapidly evolving into a supersoft X-ray source, and ultimately may explode as a Type Ia supernova within 10 Myr.
Resumo:
The presence of mobile ions complicates the implementation of voltage-modulated scanning probe microscopy techniques such as Kelvin probe force microscopy (KPFM). Overcoming this technical hurdle, however, provides a unique opportunity to probe ion dynamics and electrochemical processes in liquid environments and the possibility to unravel the underlying mechanisms behind important processes at the solid–liquid interface, including adsorption, electron transfer and electrocatalysis. Here we describe the development and implementation of electrochemical force microscopy (EcFM) to probe local bias- and time-resolved ion dynamics and electrochemical processes at the solid–liquid interface. Using EcFM, we demonstrate contact potential difference measurements, consistent with the principles of open-loop KPFM operation. We also demonstrate that EcFM can be used to investigate charge screening mechanisms and electrochemical reactions in the probe–sample junction. We further establish EcFM as a force-based imaging mode, allowing visualization of the spatial variability of sample-dependent local electrochemical properties.
Resumo:
We propose a radiation source based on a magnetic mirror cavity. Relativistic electrons are simulated entering the cavity and their trajectories and resulting emission spectra are calculated. The uniformity of the particle orbits is found to result in a frequency comb in terahertz range, the precise energies of which are tunable by varying the electron's gamma-factor. For very high energy particles, radiation friction causes the spectral harmonics to broaden and we suggest this as a possible way to verify competing classical equations of motion.
Resumo:
Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel acceleration mechanisms in terms of their angular energy distribution, conversion efficiency, and plasma density evolution.
Resumo:
We test current numerical implementations of laser-matter interactions by comparison with exact analytical results. Focusing on photon emission processes, it is found that the numerics accurately reproduce analytical emission spectra in all considered regimes, except for the harmonic structures often singled out as the most significant high-intensity (multiphoton) effects. We find that this discrepancy originates in the use of the locally constant field approximation.
Resumo:
High-order harmonics and attosecond pulses of light can be generated when ultraintense, ultrashort laser pulses reflect off a solid-density plasma with a sharp vacuum interface, i.e., a plasma mirror. We demonstrate experimentally the key influence of the steepness of the plasma-vacuum interface on the interaction, by measuring the spectral and spatial properties of harmonics generated on a plasma mirror whose initial density gradient scale length L is continuously varied. Time-resolved interferometry is used to separately measure this scale length.
Resumo:
In this work, a laser-produced plasma extreme ultraviolet source and a free electron laser were used to create Ne photo-ionized plasmas. In both cases, a radiation beam was focused onto a gas stream injected into a vacuum chamber synchronously with the radiation pulse. Extreme ultraviolet radiation from the plasma spanned a wide spectral range with pronounced maximum centered at lambda = 11 +/- 1 nm while the free electron laser pulses were emitted at a wavelength of 32 nm. The power density of the focused plasma radiation was approximately 2 x 10(7) W/cm(2) and was seven orders of magnitude lower compared with the focused free electron laser beam. Radiation fluences in both experimental conditions were comparable. Despite quite different spectral characteristics and extremely different power densities, emission spectra of both photo-ionized plasmas consist of the same spectral lines within a wavelength range of 20 to 50 nm, however, with different relative intensities of the corresponding lines. The dominating spectral lines originated from singly charged ions (Ne II); however, Ne III lines were also detected. Additionally, computer simulations of the emission spectra, obtained for photo-ionized plasmas, driven by the plasma extreme ultraviolet source, were performed. The corresponding measured and calculated spectra are presented. An electron temperature and ionic composition were estimated. Differences between the experimental spectra, obtained for both irradiation conditions, were analyzed. The differences were attributed mainly to different energies of driving photons.
Resumo:
The discovery of P/2010 A2 by the LINEAR survey in January 2010 revealed an object displaying a large trail of material similar in shape to a cometary tail although no central condensation or coma could be detected. The appearance of this object in an asteroidal orbit in the inner main belt attracted attention as a potential new member of the Main Belt Comets class (MBCs) but the discovery of a nucleus, with an estimated diameter of 120 m, around 1500 km away from the trail implied that the extended object we were seeing could be the debris trail from a recent collision rather than the tail of a comet. Due to the low inclination of its orbit, it is difficult to conclude about the nature of P/2010 A2 from Earth-based data only, as different scenarios lead to the same appearance in the orbital configuration at the times of observations. We present here another set of images, acquired from the unique viewing geometry provided by ESA's Rosetta spacecraft en route to comet 67P/Churyumov-Gerasimenko. Albeit faint (22 magnitude), the object could be observed by the high-resolution camera OSIRIS. We used a Finson-Probstein model to simulate the shape of the trail, and estimate the time of emission and β parameter (ratio between solar radiation pressure and gravity) for the dust grains. Simulations were compared to the OSIRIS images and ground based observations acquired at NTT and Palomar telescopes. Thanks to the different phase angle provided by Rosetta, we could reduce the number of solutions to a unique model, leading to the conclusive demonstration that the trail is due to a single event rather than a period of cometary activity.
Resumo:
Ultraviolet B (UVB) light is known to be immunosuppressive, but, probably because of a small UVC component in the emission spectra of some of the UVB lamps used, reports vary on effective dose levels. To prevent potentially lethal graft-versus-host disease (GVHD) after allogeneic bone marrow transplantation, alloreactive donor T-cell activity must be suppressed. In this study, a narrow wavelength UVB lamp (TL01, 312 nm peak emission) was used to determine what doses of UVB were required to abolish rat lymphocyte proliferation while simultaneously preserving rat bone marrow progenitor cell and primitive hematopoietic stem cell viability. Lymphocyte proliferation, as measured by 3H-Thymidine incorporation, in response to lectin stimulation was abolished below detection at doses greater than 3,500 J/m2. When T-cell clonogenicity was measured in a limiting dilution assay, a small fraction (0.6%) was maintained at doses up to 4,000 J/m2. Cytotoxic T-lymphocyte (CTL) activity was reduced after treatment with 4,000 J/m2, but a significant level of cytotoxicity was still maintained. Natural killer cell cytolytic activity was not affected by doses up to 4,000 J/m2. At 4,000 J+m2 there was a 10% survival of colony-forming units-granulocyte-macrophage; a 1% and 4% survival of day-8 and day-12 colony-forming units-spleen, respectively; and 11% survival of marrow repopulating ability cells. Up to 25% of late cobblestone area forming cells (4 to 5 weeks), reflecting the more immature hematopoietic stem cells, were preserved in bone marrow treated with 4,000 J/m2, indicating that early stem cells are less sensitive to UVB damage than are more committed progenitor cells. Thus, a potential therapeutic window was established at approximately 4,000 J/m2 using this light source, whereby the potentially GVHD-inducing T cells were suppressed, but a sufficient proportion of the cells responsible for engraftment was maintained.
Resumo:
Here we demonstrate a novel homogeneous one-step immunoassay, utilizing a pair of recombinant antibody antigen-binding fragments (Fab), that is specific for HT-2 toxin and has a positive readout. Advantages over the conventional competitive immunoassay formats such as enzyme-linked immunosorbent assay (ELISA) are the specificity, speed, and simplicity of the assay. Recombinant antibody HT2-10 Fab recognizing both HT-2 and T-2 toxins was developed from a phage display antibody library containing 6 × 10(7) different antibody clones. Specificity of the immunoassay was introduced by an anti-immune complex (IC) antibody binding the primary antibody-HT-2 toxin complex. When the noncompetitive immune complex assay was compared to the traditional competitive assay, an over 10-fold improvement in sensitivity was observed. Although the HT2-10 antibody has 100% cross-reactivity for HT-2 and T-2 toxins, the immune complex assay is highly specific for HT-2 alone. The assay performance with real samples was evaluated using naturally contaminated wheat reference material. The half-maximal effective concentration (EC50) value of the time-resolved fluorescence resonance energy transfer (TR-FRET) assay was 9.6 ng/mL, and the limit of detection (LOD) was 0.38 ng/mL (19 μg/kg). The labeled antibodies can be predried to the assay vials, e.g., microtiter plate wells, and readout is ready in 10 min after the sample application.
Resumo:
The basics of laser driven neutron sources, properties and possible applications are discussed. We describe the laser driven nuclear processes which trigger neutron generation, namely, nuclear reactions induced by laser driven ion beam (ion n), thermonuclear fusion by implosion and photo-induced nuclear (gamma n) reactions. Based on their main properties, i.e. point source (< 100 μm) and short durations (< ns), different applications are described, such as radiography, time-resolved spectroscopy and pump-probe experiments. Prospects on the development of laser technology suggest that, as higher intensities and higher repetition rate lasers become available (for example, using DPSSL technology), laser driven methodologies may provide neutron fluxes comparable to that achieved by accelerator driven neutron sources in the near future.