135 resultados para SIMPLE MULTICLOUD PARAMETERIZATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple non-linear global-local finite element methodology is presented. A global coarse model, using 2-D shell elements, is solved non-linearly and the displacements and rotations around a region of interest are applied, as displacement boundary conditions, to a refined local 3-D model using Kirchhoff plate assumptions. The global elements' shape functions are used to interpolate between nodes. The local model is then solved non-linearly with an incremental scheme independent of that used for the global model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Centane magisterial area of South Africa, high rates of oesophageal cancer have been associated with home-grown maize contaminated with fumonisins. The aim of this study was to implement a simple intervention method to reduce fumonisin exposure in a subsistence-farming community. The hand-sorting and washing procedures, based on traditional maize-based food preparation practices, were previously customised under laboratory-controlled conditions. Home-grown maize and maize-based porridge collected at baseline were analysed for fumonisin B1, B2 and B3. The geometric mean (95% confidence interval) of fumonisin contamination in the home-grown maize at baseline was 1.67 (1.21-2.32) mg kg-1 and 1.24 (0.75-2.04) mg kg -1 (dry weight) in the porridge. Fumonisin exposure was based on individual stiff porridge consumption and the specific fumonisin levels in the porridge (dry weight) consumed. Porridge (dry weight) consumption at baseline was 0.34 kg day-1 and fumonisin exposure was 6.73 (3.90-11.6) mu g kg-1 body weight day-1. Female participants (n = 22) were trained to recognise and remove visibly infected/damaged kernels and to wash the remaining maize kernels. The discarded kernels represented 3.9% by weight and the fumonisins varied from 17.1 to 76.9 mg kg-1. The customised hand-sorting and washing procedures reduced fumonisin contamination in the maize and porridge by 84 and 65%, respectively. The intervention reduced fumonisin exposure by 62% to 2.55 (1.94-3.35) mu g kg-1 body weight day-1. This simple intervention method has the potential to improve food safety and health in subsistence-farming communities consuming fumonisin-contaminated maize as their staple diet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthesis of cobalt-doped ZnO nanowires is achieved using a simple, metal salt decomposition growth technique. A sequence of drop casting on a quartz substrate held at 100 degrees C and annealing results in the growth of nanowires of average (modal) length similar to 200 nm and diameter of 15 +/- 4 nm and consequently an aspect ratio of similar to 13. A variation in the synthesis process, where the solution of mixed salts is deposited on the substrate at 25 degrees C, yields a grainy film structure which constitutes a useful comparator case. X-ray diffraction shows a preferred [0001] growth direction for the nanowires while a small unit cell volume contraction for Co-doped samples and data from Raman spectroscopy indicate incorporation of the Co dopant into the lattice; neither technique shows explicit evidence of cobalt oxides. Also the nanowire samples display excellent optical transmission across the entire visible range, as well as strong photoluminescence (exciton emission) in the near UV, centered at 3.25 eV. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An increasing number of publications on the dried blood spot (DBS) sampling approach for the quantification of drugs and metabolites have been spurred on by the inherent advantages of this sampling technique. In the present research, a selective and sensitive high-performance liquid chromatography method for the concurrent determination of multiple antiepileptic drugs (AEDs) [levetiracetam (LVT), lamotrigine (LTG), phenobarbital (PHB)], carbamazepine (CBZ) and its active metabolite carbamazepine-10,11 epoxide (CBZE)] in a single DBS has been developed and validated. Whole blood was spotted onto Guthrie cards and dried. Using a standard punch (6. mm diameter), a circular disc was punched from the card and extracted with methanol: acetonitrile (3:1, v/v) containing hexobarbital (Internal Standard) and sonicated prior to evaporation. The extract was then dissolved in water and vortex mixed before undergoing solid phase extraction using HLB cartridges. Chromatographic separation of the AEDs was achieved using Waters XBridge™ C18 column with a gradient system. The developed method was linear over the concentration ranges studied with r=0.995 for all compounds. The lower limits of quantification (LLOQs) were 2, 1, 2, 0.5 and 1. µg/mL for LVT, LTG, PHB, CBZE and CBZ, respectively. Accuracy (%RE) and precision (%CV) values for within and between day were

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electron deficient active sites in Pd catalysts, either as films or on supports, are deliberately generated by calcining in O-2 at high temperature followed by the mildest possible reduction (with the reaction mixture itself), and are manifested by a marked shift from multiple to simple exchange in the cyclopentane/D-2 probe reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we describe a simple and efficient method for on-chip storage of reagents for point-of-care (POC) diagnostics. The method is based on gelification of all reagents required for on-chip PCR-based diagnostics as a ready-to-use product. The result reported here is a key step towards the development of a ready and easy to use fully integrated Lab-on-a-chip (LOC) system for fast, cost-effective and efficient POC diagnostics analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sympathetic and parasympathetic divisions of the autonomic nervous system constantly control the heart (sympathetic and parasympathetic divisions) and blood vessels (predominantly the sympathetic division) to maintain appropriate blood pressure and organ blood flow over sometimes widely varying conditions. This can be adversely affected by pathological conditions that can damage one or both branches of autonomic control. The set of teaching laboratory activities outlined here uses various interventions, namely, 1) the heart rate response to deep breathing, 2) the heart rate response to a Valsalva maneuver, 3) the heart rate response to standing, and 4) the blood pressure response to standing, that cause fairly predictable disturbances in cardiovascular parameters in normal circumstances, which serve to demonstrate the dynamic control of the cardiovascular system by autonomic nerves. These tests are also used clinically to help investigate potential damage to this control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a simple and facile methodology for constructing Pt (6.3 mm x 50 mu m) and Cu (6.3 mm x 30 mu m) annular microband electrodes for use in room temperature ionic liquids (RTILs) and propose their use for amperometric gas sensing. The suitability of microband electrodes for use in electrochemical analysis was examined in experiments on two systems. The first system studied to validate the electrochemical responses of the annular microband electrode was decamethylferrocene (DmFc), as a stable internal reference probe commonly used in ionic liquids, in [Pmim][NTf2], where the diffusion coefficients of DmFc and DmFc(+) and the standard electron rate constant for the DmFc/DmFc(+) couple were determined through fitting chronoamperometric and cyclic voltammetric responses with relevant simulations. These values are independently compared with those collected from a commercially available Pt microdisc electrode with excellent agreement. The second system focuses on O-2 reduction in [Pmim][NTf2], which is used as a model for gas sensing. The diffusion coefficients of O-2 and O-2(-) and the electron transfer rate constant were again obtained using chronoamperometry and cyclic voltammetry, along with simulations. Results determined from the microbands are again consistent to those evaluated from the Pt microdisc electrode when compared these results from home-made microband and commercially available microdisc electrodes. These observations indicate that the fabricated annular microband electrodes are suitable for quantitative measurements. Further the successful use of the Cu electrodes in the O-2 system suggests a cheap disposable sensor for gas detection. (C) 2013 Elsevier B.V. All rights reserved.