111 resultados para Intraocular-lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 10 GHz Fourier Rotman lens enabled dynamic directional modulation (DM) transmitter is experimentally evaluated. Bit error rate (BER) performance is obtained via real-time data transmission. It is shown that Fourier Rotman DM functionality enhances system security performance in terms of narrower decodable low BER region and higher BER values associated with BER sidelobes especially under high signal to noise ratio (SNR) scenarios. This enhancement is achieved by controlled corruption of constellation diagrams in IQ space by orthogonal injection of interference. Furthermore, the paper gives the first report of a functional dual-beam DM transmitter, which has the capability of simultaneously projecting two independent data streams into two different spatial directions while simultaneously scrambling the information signals along all other directions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution imaging of a dipole source in stratified medium based on negative refraction is presented in this paper. Compensation of the material parameter contrast at the stratified media interface is achieved using a gradient phase profiled conjugating lens (GPCL). It is shown both analytically and numerically that the phase gradient applied across the GPCL positioned at the interface of vertically stratified media enables a high-quality image of a dipole source in a mirror symmetric position with respect to the lens plane. The analytical closed form expression of the phase gradient function is derived using Huygens-Kirchhoff principle. The result is applicable to media with arbitrary stratification and material parameters, including lossy materials. The mechanism for formation of the dipole image in the stratified medium and aberration due to the dielectric contrast at the interface, particularly electromagnetic loss, is discussed in detail. The efficacy of gradient phase and amplitude aberration compensations mechanisms available through the GPCL is articulated. The results of the study are of importance in a wide range of imaging problems in stratified media for medical, civil, and military applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using polycapillary lenses to focus laser-produced x-ray sources to high intensities, an improvement in signal-to-noise ratio can be achieved. Here the He-alpha line emission produced by driving a titanium backlighter target is focused by a polycapillary lens and the output characterized. The x-ray spot is measured to have a peak intensity of 4.5 x 10(7) photons, with a total photon count of 8.8 x 10(8) in 0.13 +/- 0.01 mm(2). This setup is equivalent to placing the backlighter target 3 mm from the sample with a 600 mu m diameter pinhole. The polycapillary lens enables the placement of the backlighter target at a much larger distance from the sample to be studied and therefore has the ability to greatly improve the signal-to-noise ratio on detectors. We demonstrate this with two simple diffraction experiments using pyrolytic graphite and polycrystalline aluminium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 94 GHz waveguide Rotman lens is described which can be used to implement an amplitude comparison monopulse RADAR. In transmit mode, adjacent dual beam ports are excited with equal amplitude and phase to form a sum radiation pattern, and in receive mode, the outputs of the beam port pairs are combined using magic tees to provide a sum and a difference signal which can be used to calculate an angular error estimate for target acquisition and tracking. This approach provides an amplitude comparison monopulse system which can be scanned in azimuth and which has a low component count, with no requirement for phase shift circuitry in the array feed lines, making it suitable for mm-wave frequencies. A 12 input (beam ports), 12 output (array ports) lens is designed using CST Microwave Studio, and the predicted results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current therapies that target vascular endothelial growth factor (VEGF) have become a mainstream therapy for the management of diabetic macular oedema. The treatment involves monthly repeated intravitreal injections of VEGF inhibitors. VEGF is an important growth factor for many retinal cells, including different types of neurons. In this study, we investigated the adverse effect of multiple intravitreal anti-VEGF injections (200 ng/μl/eye anti-mouse VEGF164, once every 2 weeks totalling 5-6 injections) to retinal neurons in Ins2(Akita) diabetic mice. Funduscopic examination revealed the development of cotton wool spot-like lesions in anti-VEGF treated Ins2(Akita) mice after 5 injections. Histological investigation showed focal swellings of retinal nerve fibres with neurofilament disruption. Furthermore, anti-VEGF-treated Ins2(Akita) mice exhibited impaired electroretinographic responses, characterized by reduced scotopic a- and b-wave and oscillatory potentials. Immunofluorescent staining revealed impairment of photoreceptors, disruptions of synaptic structures and loss of amacrine and retinal ganglion cells in anti-VEGF treated Ins2(Akita) mice. Anti-VEGF-treated WT mice also presented mild amacrine and ganglion cell death, but no overt abnormalities in photoreceptors and synaptic structures. At the vascular level, exacerbated albumin leakage was observed in anti-VEGF injected diabetic mice. Our results suggest that sustained intraocular VEGF neutralization induces retinal neurodegeneration and vascular damage in the diabetic eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TOPIC:

To analyze the literature pertaining to the techniques used in combined cataract and glaucoma surgery, including the technique of cataract extraction, the timing of the surgery (staged procedure versus combined procedure), the anatomic location of the operation, and the use of antifibrosis agents.

CLINICAL RELEVANCE:

Cataract and glaucoma are both common conditions and are often present in the same patient. There is no agreement concerning the optimal surgical management of these disorders when they coexist.

METHODS/LITERATURE REVIEWED:

Electronic searches of English language articles published since 1964 were conducted in Pub MED and CENTRAL, the Cochrane Collaboration's database. These were augmented by a hand search of six ophthalmology journals and the reference lists of a sample of studies included in the literature review. Evidence grades (A, strong; B, moderate; C, weak; I, insufficient) were assigned to the evidence that involved a direct comparison of alternative techniques.

RESULTS:

The preponderance of evidence from the literature suggests a small (2-4 mmHg) benefit from the use of mitomycin-C (MMC), but not 5-fluorouracil (5-FU), in combined cataract and glaucoma surgery (evidence grade B). Two-site surgery provides slightly lower (1-3 mmHg) intraocular pressure (IOP) than one-site surgery (evidence grade C), and IOP is lowered more (1-3 mmHg) by phacoemulsification than by nuclear expression in combined procedures (evidence grade C). There is insufficient evidence to conclude either that staged or combined procedures give better results or that alternative glaucoma procedures are superior to trabeculectomy in combined procedures.

CONCLUSIONS:

In the literature on surgical techniques and adjuvants used in the management of coexisting cataract and glaucoma, the strongest evidence of efficacy exists for using MMC, separating the incisions for cataract and glaucoma surgery, and removing the nucleus by phacoemulsification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE:

To investigate the heritability of intraocular pressure (IOP) and cup-to-disc ratio (CDR) in an older well-defined population.

DESIGN:

Family-based cohort study.

PARTICIPANTS:

Through the population-based Salisbury Eye Evaluation study, we recruited 726 siblings (mean age, 74.7 years) in 284 sibships.

METHODS:

Intraocular pressure and CDR were measured bilaterally for all participants. The presence or absence of glaucoma was determined by a glaucoma specialist for all probands on the basis of visual field, optic nerve appearance, and history. The heritability of IOP was calculated as twice the residual between-sibling correlation of IOP using linear regression and generalized estimating equations after adjusting for age, gender, mean arterial pressure, race, self-reported diabetes status, and history of systemic steroid use. The heritability of CDR was calculated using the same model and adjustments as above, while also adjusting for IOP.

MAIN OUTCOME MEASURES:

Heritability and determinants of IOP and CDR, and impact of siblings' glaucoma status on IOP and CDR.

RESULTS:

We estimated the heritability to be 0.29 (95% confidence interval [CI], 0.12-0.46) for IOP and 0.56 (95% CI, 0.35-0.76) for CDR in this population. Mean IOP in siblings of glaucomatous probands was statistically significantly higher than in siblings of normal probands (mean difference, 1.02 mmHg; P = 0.017). The mean CDR in siblings of glaucomatous probands was 0.07 (or 19%) larger than in siblings of glaucoma suspect referrals (P = 0.045) and siblings of normal probands (P = 0.004).

CONCLUSIONS:

In this elderly population, we found CDR to be highly heritable and IOP to be moderately heritable. On average, siblings of glaucoma patients had higher IOPs and larger CDRs than siblings of nonglaucomatous probands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To establish the relationship between myopia and lens opacity. DESIGN: Population-based cross-sectional study. PARTICIPANTS: Two thousand five hundred twenty participants from the Salisbury Eye Evaluation aged 65 to 84 years. METHODS: Participants filled out questionnaires regarding medical history, social habits, and a detailed history of distance spectacle wear. They underwent a full ocular examination. Lens photographs were taken for assessment of lens opacity using the Wilmer grading system. Multivariate logistic regression models using generalized estimating equations were used to analyze the relationship between lens opacity type and degree of myopia, while accounting for potential confounders. MAIN OUTCOME MEASURES: Presence of posterior subcapsular opacity, cortical opacity, or nuclear opacity. RESULTS: Significant associations were found between myopia and both nuclear and posterior subcapsular opacities. For nuclear opacity, the odds ratios (ORs) were 2.25 for myopia between -0.50 diopters (D) and -1.99 D (P<0.001), 3.65 for myopia between -2.00 D and -3.99 D (P<0.001), 4.54 for myopia between -4.00 D and -5.99 D (P<0.001), and 3.61 for myopia -6.00 D or more (P = 0.002). For posterior subcapsular cataracts, ORs were 1.59 for myopia between -0.50 D and -1.99 D (P = 0.11), 3.22 for myopia between -2.00 D and -3.99 D (P = 0.002), 5.36 for myopia between -4.00 D and -5.99 D (P<0.001), and 12.34 for myopia -6.00 D or more (P<0.001). No association was found between myopia and cortical opacity. The association between posterior subcapsular opacity and myopia was equally strong for those wearing glasses by age 21 years and for those without glasses; for nuclear opacity, significantly higher ORs were found for myopes who started wearing glasses after age 21. CONCLUSIONS: These results confirm the previously reported association between myopia, posterior subcapsular opacity, and nuclear opacity. Furthermore, the strong association between early spectacle wear and posterior subcapsular opacity among myopes, absent for nuclear opacity, suggests that myopia may precede opacity in the case of posterior subcapsular opacity, but not nuclear opacity. Measures of association between posterior subcapsular opacity and myopia were stronger in the current study than have previously been found. Longitudinal studies to confirm the association are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We studied the effects on intraocular pressure (IOP) of anesthesia administered during examination under anesthesia (EUA) in children. DESIGN: Randomized clinical trial. METHODS: This randomized trial compared IOP after inhaled sevoflurane gas to that after intramuscular ketamine hydrochloride in children undergoing EUA. IOP was measured in 30 eyes with TonoPen XL (Mentor, Inc, Norwell, Massachusetts, USA) as soon as possible after anesthesia induction (T1) and two, four, six, and eight minutes thereafter. At the same times, we recorded systolic and diastolic blood pressure (SBP, DBP) and heart rate (HR). RESULTS: Compared with the mean IOP at T1, IOP in the sevoflurane group was significantly lower for all measurements from two to eight minutes thereafter (mean decrease in IOP: two minutes = 12%, four minutes = 19%; six minutes = 19%; eight minutes = 17%, all P < or = .01). In the ketamine group, mean IOP was not significantly changed from T1 through six minutes, whereas at eight minutes, it was 7% lower (P = .03). SBP and DBP were significantly lower for sevoflurane than for ketamine at all measurements from two minutes onward, and HR was lower for sevoflurane than for ketamine at two, four, and six minutes. CONCLUSIONS: IOP measured after ketamine sedation is more likely to represent the awake IOP than that after sevoflurane anesthesia. Changes in SBP, DBP, and HR caused by sevoflurane suggest that hemodynamic alterations may underlie its effects on IOP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To clarify the risk parameters measured by anterior segment optical coherence tomography (AS-OCT) for elevated intraocular pressures (IOP) provoked by the darkroom test and to provide recommendations for its clinical usage. METHODS: Subjects aged >40 years and whose peripheral anterior chambers were ≤1/4 corneal thickness were recruited. The anterior segment of the eye was imaged in sitting position and under both light and dark conditions and biometry was performed using anterior segment optical coherence tomography. The analyzed parameters were: (1) central anterior chamber depth (ACD); (2) anterior chamber width; (3) pupil diameter; (4) iris curvature; (5) lens thickness; and (6) number of meridians with closed angles (NCA). Then the darkroom test was performed and a positive provocative test result was defined as a rise in IOP ≥8 mm Hg after the test. Statistical analyses included: (1) the difference in parameters between positive and negative eyes; (2) the association between posttest IOP and the parameters; and (3) the difference in parameters between the 2 eyes in subjects with the asymmetric results. RESULTS: A total of 70 subjects were recruited. ACD (P=0.022), NCA in light (P<0.001), and NCA in dark (P<0.001) were different significantly between eyes with positive and negative results. There was a strong association between NCA in dark (r=0.755, P<0.001) and the posttest IOP. Among subjects with asymmetric results between the 2 eyes, the ACD was shallower and the lens thickness was larger in the positive eye. CONCLUSIONS: The posttest IOP is determined by the extent of functionally closed angles in the dark. The test may be useful in the early diagnosis of primary angle closure. At the same time, angle configuration should be evaluated to remove false positive result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To study the accuracy and acceptability of intraocular pressure (IOP) measurement by the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer in children. METHODS: Fifty children (5 to 14 years old) participated in this prospective comparative study. IOP was measured with the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer by three different examiners who were masked to the results. The children were also asked to grade the degree of discomfort from 0 to 5 (0 = no discomfort; 5 = most discomfort). RESULTS: The mean IOPs measured by the Goldmann tonometer, pressure phosphene tonometer, and non-contact tonometer were 15.9 mm Hg (standard deviation [SD]: = 5.5 mm Hg; range: 10 to 36 mm Hg), 16.0 mm Hg (SD: 2.9 mm Hg; range: 12 to 25 mm Hg), and 15.7 mm Hg (SD = 5.1 mm Hg; range: 8 to 32 mm Hg), respectively (P = .722). The mean difference between pressure phosphene tonometer and Goldmann tonometer readings was 2.9 mm Hg and that between non-contact tonometer and Goldmann tonometer readings was 2.1 mm Hg. The 95% confidence interval of the mean difference between pressure phosphene tonometer and Goldmann tonometer readings was -1.07 and 1.19, and that between non-contact tonometer and Goldmann tonometer readings was -1.07 and 0.53. The mean discomfort ratings for the pressure phosphene tonometer, non-contact tonometer, and Goldmann tonometer were 0.6, 2.0, and 2.3, respectively (P < .001). CONCLUSION: Although the pressure phosphene tonometer was less accurate than the non-contact tonometer compared with Goldmann tonometer, it gave a reasonably close estimate and had a high specificity of raised IOP. In addition, measurement by the pressure phosphene tonometer is most acceptable to children. The pressure phosphene tonometer can be considered as an alternative method of IOP measurement in children.