321 resultados para serum diagnosis
Resumo:
BACKGROUND.: High serum phosphate has been identified as an important contributor to the vascular calcification seen in patients with chronic kidney disease (Block et al., Am J Kidney Dis 1998; 31: 607). In patients on hemodialysis, elevated serum phosphate levels are an independent predictor of mortality (Block et al., Am J Kidney Dis 1998; 31: 607; Block, Curr Opin Nephrol Hypertens 2001; 10: 741). The aim of this study was to investigate whether an elevated serum phosphate level was an independent predictor of mortality in patients with a renal transplant.
METHODS.: Three hundred seventy-nine asymptomatic renal transplant recipients were recruited between June 2000 and December 2002. Serum phosphate was measured at baseline and prospective follow-up data were collected at a median of 2441 days after enrolment.
RESULTS.: Serum phosphate was significantly higher in those renal transplant recipients who died at follow-up when compared with those who were still alive at follow-up (P<0.001). In Kaplan-Meier analysis, serum phosphate concentration was a significant predictor of mortality (P=0.0001). In multivariate Cox regression analysis, serum phosphate concentration remained a statistically significant predictor of all-cause mortality after adjustment for traditional cardiovascular risk factors, estimated glomerular filtration rate, and high sensitivity C reactive protein (P=0.036) and after adjustment for renal graft failure (P=0.001).
CONCLUSIONS.: The results of this prospective study are the first to show that a higher serum phosphate is a predictor of mortality in patients with a renal transplant and suggest that serum phosphate provides additional, independent, prognostic information to that provided by traditional risk factors in the risk assessment of patients with a renal transplant.
Resumo:
Lung cancer is the most common cause of cancer death. The conventional method of confirming the diagnosis is bronchoscopy, inspecting the airways of the patient with a fiber optic endoscope. A number of studies have shown that Raman spectroscopy can diagnose lung cancer in vitro. In this study, Raman spectra were obtained from ex vivo normal and malignant lung tissue using a minifiber optic Raman probe suitable for insertion into the working channel of a bronchoscope. Shifted subtracted Raman spectroscopy was used to reduce the fluorescence from the lung tissue. Using principal component analysis with a leave-one-out analysis, the tissues were classified accurately. This novel technique has the potential to obtain Raman spectra from tumors from patients with lung cancer in vivo.
Resumo:
This paper introduces an automated computer- assisted system for the diagnosis of cervical intraepithelial neoplasia (CIN) using ultra-large cervical histological digital slides. The system contains two parts: the segmentation of squamous epithelium and the diagnosis of CIN. For the segmentation, to reduce processing time, a multiresolution method is developed. The squamous epithelium layer is first segmented at a low (2X) resolution. The boundaries are further fine tuned at a higher (20X) resolution. The block-based segmentation method uses robust texture feature vectors in combination with support vector machines (SVMs) to perform classification. Medical rules are finally applied. In testing, segmentation using 31 digital slides achieves 94.25% accuracy. For the diagnosis of CIN, changes in nuclei structure and morphology along lines perpendicular to the main axis of the squamous epithelium are quantified and classified. Using multi-category SVM, perpendicular lines are classified into Normal, CIN I, CIN II, and CIN III. The robustness of the system in term of regional diagnosis is measured against pathologists' diagnoses and inter-observer variability between two pathologists is considered. Initial results suggest that the system has potential as a tool both to assist in pathologists' diagnoses, and in training.
Resumo:
Bovine serum albumin (BSA) is a commonly used model protein in the development of pharmaceutical formulations. In order to assay its release from various dosage forms, either the bicinchoninic acid (BCA) assay or a more specific size-exclusion high performance liquid chromatography (SE-HPLC) method are commonly employed. However, these can give erroneous results in the presence of some commonly-used pharmaceutical excipients. We therefore investigated the ability of these methods to accurately determine BSA concentrations in pharmaceutical formulations that also contained various polymers and compared them with a new and compared with a new reverse-phase (RP)–HPLC technique. We found that the RP-HPLC technique was the most suitable method. It gave a linear response in the range of 0.5 -100 µg/ml with a correlation coefficient of 0.9999, a limit of detection of 0.11 µg/ml and quantification of 0.33 µg/ml. The performed ‘t’ test for the estimated and theoretical concentration indicated no significant difference between them providing the accuracy. Low % relative standard deviation values (0.8-1.39%) indicate the precision of the method. Furthermore, the method was used to quantify in vitro BSA release from polymeric freeze-dried formulations.