108 resultados para STOP BAND
Resumo:
Email
Print
Request Permissions
A compact V-band active power detector using Infineon 0.35 µm SiGe HBT process (fT/fmax =170/250 GHz) is described. The total chip area is only 0.35×0.8 mm2 including all pads. This design exhibits a dynamic range larger than 20 dB over the frequency range from 55 GHz to 67 GHz. It also offers a simple and low-power application potential as an envelop detector in multi-Gbps high data rate demodulators for OOK/ASK etc.
Resumo:
We present time-resolved J-band spectroscopy of the short-period cataclysmic variable SDSS J143317.78+101123.3. We detect absorption lines from the sub-stellar donor star in this system, which contributes 38 +/- 5 per cent to the J-band light. From the relative strengths of the absorption lines in the J band, we estimate the spectral type of the donor star to be L2 +/- 1. These data are the first spectroscopic detection of a donor with a confirmed sub-stellar mass in a cataclysmic variable, and the spectral type is consistent with that expected from semi-empirical evolutionary models.
Using skew mapping, we have been able to derive an estimate for the radial velocity of the donor of K-d = 520 +/- 60 km/s. This value is consistent with, though much less precise than, predictions from mass determinations found via photometric fitting of the eclipse light curves.
Resumo:
This Letter reports in situ Fourier transform infrared (FTIR) spectroscopic data on thermal TiO films fabricated by heating titanium plates in air at 475, 700 and 800 °C. The films were studied in the dark and under UV-irradiation in aqueous 0.1MNaClO in the presence and absence of 0.1 M Na(OOC) and at 10, 25 and 50 °C. The film fabricated at 800 °C showed a broad feature near 1580cm under UV-irradiation that was not observed in the dark, whilst the films fabricated at lower temperatures, 475 and 700 °C, showed no such feature. This feature appears to be associated with the accumulation of surface-mobile holes at the complex, porous film-electrolyte interface and the capacity of such holes to enhance the absorption cross-section of optical phonons characteristic of the rutile crystal form at and near the surface of the TiO/electrolyte interface. © 2001 Elsevier Science B.V.
Resumo:
We present the probable ground-based detection of the secondary eclipse of the transiting exoplanet WASP-19b. The observations were made in the Sloan z'-band using the ULTRACAM triple-beam CCD camera mounted on the NTT. The measurement shows a 1±0.2mmag eclipse depth, consistent with a dayside temperature of 2900K, matching previous predictions based on H- and K-band measurements. However, since this is based on a single observation, the eclipse depth - at the moment - is not particularly well constrained, and would benefit from additional observations at similar wavelengths. Our technique for the data reduction and analysis is described, along with our approach to dealing with systematic errors associated with ground-based secondary eclipse observations.
Resumo:
Single and double layer frequency selective surfaces (FSS) for Circular polarization (CP) operation were designed. The designed FSS provide reflection in the Ku-band (11.7 – 12.75 GHz) and transmission in the Ka-band (17.3 – 20.2 GHz). CP is conserved in each of the bands. For the double layer design over the Ku-band the reflection loss was less than 0.05 dB for TE and TM polarizations while the axial ratio was below 0.2 dB. Over the Ka-band transmission loss and axial ratio were each less than 0.25 dB.
Resumo:
A frequency selective surface (FSS) which can be utilized as a diplexer for circular polarization (CP) applications is proposed. The structure consists of two dipole-based FSS placed parallel to each other. The dipoles in one array are rotated by 90° with respect to those in the other. For an angle of incidence of 45° at one frequency band the structure allows a CP signal to be transmitted while at a further band it converts a linearly polarized (LP) signal to CP upon reflection. Full-wave simulation results validated the concept.
Resumo:
This paper presents the design and implementation of a differential 4-way power-combining amplifier operating at E-band. The proposed 4-way power combiner (4WPC) facilitates short interconnects to the PA cells, thereby resulting in reduced loss. Simple C-L-C and L-C networks are deployed in order to compensate inductive loading due to the routing lines that would otherwise introduce mismatch and subsequently increase overall loss. Realized in SiGe technology, the PA prototype delivered 13.2 dBm output-referred 1-dB compression point and 14.3 dBm saturated output power when operated from a single 3.3 V DC supply at 75 GHz.
Resumo:
Background: Chronic kidney disease (CKD) patients on dialysis are prone to vitamin D insufficiency despite oral vitamin D supplementation. Here, we studied whether narrow-band ultraviolet B (NB-UVB) exposures improve vitamin D balance.
Methods: 14 haemodialysis patients and 15 healthy subjects receiving oral cholecalciferol 20 µg daily got nine NB-UVB exposures on the entire body. Serum 25-hydroxyvitamin D (25(OH)D) was measured by radioimmunoassay. Cutaneous mRNA expression levels of CYP27A1 and CYP27B1, two enzymes required for hydroxylation of vitamin D into its active metabolite, were also measured.
Results: The baseline serum 25(OH)D concentration was 57.6 ± 18.2 nmol/l in the CKD patients and 74.3 ± 14.8 nmol/l in the healthy subjects. The NB-UVB course increased serum 25(OH)D by 14.0 nmol/l (95% CI 8.7-19.5) and 17.0 nmol/l (CI 13.7-20.2), respectively. At baseline the CKD patients showed significantly increased CYP27B1 levels compared to the healthy subjects.
Conclusions: A short NB-UVB course is an efficient way to improve vitamin D balance in CKD patients on dialysis who are receiving oral vitamin D supplementation. The increased cutaneous CYP27B1 levels in the CKD patients suggest that the loss of renal activity of this enzyme is at least partially compensated for by the skin.
Resumo:
A course of treatment with narrow-band ultraviolet B (NB-UVB) improves psoriasis and increases serum 25-hydroxyvitamin D (25(OH)D). In this study 12 patients with psoriasis who were supplemented with oral cholecalciferol, 20 µg daily, were given a course of NB-UVB and their response measured. At baseline, serum 25(OH)D was 74.14 ± 22.9 nmol/l. At the 9th exposure to NB-UVB 25(OH)D had increased by 13.2 nmol/l (95% confidence interval (95% CI) 7.2–18.4) and at the 18th exposure by 49.4 nmol/l (95% CI 35.9–64.6) above baseline. Psoriasis Area Severity Index score improved from 8.7 ± 3.5 to 4.5 ± 2.0 (p < 0.001). At baseline, psoriasis lesions showed low vitamin D metabolizing enzyme (CYP27A1, CYP27B1) and high human β-defensin-2 mRNA expression levels compared with those of the healthy subjects. In conclusion, NB-UVB treatment significantly increases serum 25(OH)D in patients with psoriasis who are taking oral vitamin D supplementation, and the concentrations remain far from the toxicity level. Healing psoriasis lesions show similar mRNA expression of vitamin D metabolizing enzymes, but higher antimicrobial peptide levels than NB-UVB-treated skin in healthy subjects.
Resumo:
Chronic kidney disease (CKD) patients are especially prone to vitamin D insufficiency. Narrow-band ultraviolet B (NB-UVB) treatment increases serum 25-hydroxyvitamin D [25(OH)D] in dermatological patients, and we studied whether it also improves vitamin D balance in CKD patients on haemodialysis.