91 resultados para Raman spectroscopy, borickyite, phosphate, sulphate, delvauxite


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main curative therapy for patients with nonsmall cell lung cancer is surgery. Despite this, the survival rate is only 50%, therefore it is important to more efficiently diagnose and predict prognosis for lung cancer patients. Raman spectroscopy is useful in the diagnosis of malignant and premalignant lesions. The aim of this study is to investigate the ability of Raman microscopy to diagnose lung cancer from surgically resected tissue sections, and predict the prognosis of these patients. Tumor tissue sections from curative resections are mapped by Raman microscopy and the spectra analzsed using multivariate techniques. Spectra from the tumor samples are also compared with their outcome data to define their prognostic significance. Using principal component analysis and random forest classification, Raman microscopy differentiates malignant from normal lung tissue. Principal component analysis of 34 tumor spectra predicts early postoperative cancer recurrence with a sensitivity of 73% and specificity of 74%. Spectral analysis reveals elevated porphyrin levels in the normal samples and more DNA in the tumor samples. Raman microscopy can be a useful technique for the diagnosis and prognosis of lung cancer patients receiving surgery, and for elucidating the biochemical properties of lung tumors. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3323088]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the formation of highly scattering silver complexes of adenine, deoxyadenosine and 5'-dAMP under alkaline pH conditions in the colloidal silver solutions which are used for surface-enhanced Raman spectroscopy. These complexes, and other pH-dependent phenomena, help to explain the diversity of previously reported adenine SERS spectra. Using conditions which promote complex formation allows nucleotides to be detected at <1 ppm, even in solutions with high salt concentrations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The resonance Raman spectra of the lowest lying singlet (S-1) state of free-base tetraphenylporphyrin and seven of its isotopomers were recorded under pump-and-probe conditions with a time delay of -2 ns between pump and probe laser pulses, In the S-1 spectra of the isotopomers, as in the ground state, there are dramatic splittings of what appear to be single bands in the natural isotopic abundance spectrum. The most structurally significant bands of the S-1 state were assigned on the basis of the isotope data, In some cases it was necessary to curve fit unresolved bands in the excited-state spectra in order to account for observed intensity ratios and to rationalize isotope shifts, The changes in band positions on excitation to the S-1 state were compared with those from earlier studies on the T-1 state. The changes in band positions were found to be similar For both excited states. Most notable was the similar shift in nu(2), the most widely used marker band for orbital character. The data are interpreted as implying that the lowest lying singlet state is a configuration interaction admixture of b(1u)b(2g) + a(u)b(3g) configurations with the coefficients weighted heavily in favour of b(1n)b(2g), which Is the configuration of the T-1 state. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies by laser flash photolysis, transient Raman spectroscopy, and Raman and UV-vis spectroelectrochemistry are described in which the techniques have been used in parallel to compare the lowest energy charge-transfer excited states of Cu (1) complexes ([Cu(L)2]+ and [ (PPh3)2Cu(L)]+ [L = 2,2'-biquinoline (BIQ) or 6,7-dihydro-5,8-dimethyldibenzo[b,j] [1,10]-phenanthroline (DMCH)) with the species produced by electrochemical reduction in the same group of complexes. Transient resonance Raman spectra for the metal-to-ligand charge-transfer (MLCT) states of [Cu(DMCH)2]+ (1), [Cu(BIQ)2]+ (2), [Cu(DMCH)(PPh3)2]+ (3), and [Cu(BIQ)(PPh3)2]+ (4) are compared with the resonance Raman spectra of the same group of complexes following one-electron electrochemical reduction of the DMCH and BIQ ligands. The UV-vis and resonance Raman evidence suggests that the electrochemical reduction of the [Cu(I)L2]+ species proceeds according to the sequence [LCu(I)L]+ -->e- [LCu0L] -->e- [L.-Cu(I)L.-]-. Several features assignable to modes of the electrochemically generated DMCH.-and BIQ'- radical anions exhibit a close correspondence in both frequency and relative intensity with counterparts in the spectra of the MLCT states of 1 and 2. A notable exception is a band near 1590 cm-1 in the spectra of the electrochemically reduced species which occurs some 15 cm-1 lower in the corresponding spectra of the excited-state species. It is suggested that the shift may reflect the change in oxidation state of the metal center from Cu(I) to Cu(II) which occurs as a result of charge-transfer excitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface-enhanced Raman scattering (SERS) excited at several visible wavelengths and recorded using a cooled charged-coupled device detector is reported from the mobile, interfacial, liquid-like metal films (MELLFs) formed when solutions of metal complexes or pyridine in chlorocarbon solvents are mixed with aqueous sols of silver or gold. MELLF formation has not previously been reported for gold sols or for pyridine as stabilizer. Comparison of the spectra for the MELLFs formed from individual metal complexes and from 50:50 mixtures show that the spectral patterns observed for the latter are distinctive and are not generally equivalent to the sum of the spectra associated with the individual complexes, in contrast to the situation observed for sols where the individual spectra do appear to be additive. Raman scattering from both gold and silver MELLFs is readily observed at excitation wavelengths in the red, around 750 nm, but at 514 nm only that from silver films is detectable. These findings are considered in terms of particle size and absorption band intensities. A preliminary study of the film surface topography and particle size was carried out by scanning tunnelling electron microscopy (STM) of Ag MELLFs deposited on gold-coated mica substrates. Computer-processed images of the STM data show the presence on the film surface of finger-like bars, 200-400 nm long with approximately square cross-section, 40-60 nm side, together with other smaller cuboid features. The implications of these findings in relation to SERS are briefly considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resonance Raman spectroscopy has been used to probe the structures of; tetrakis(1-methylpyridinium-4-yl)-porphinatoiron(III), FeIII (T4MPyP); tetrakis(1-methylpyridium-2-yl)porphinatoiron(III), FeIII (T2MPyP); tetrakis(4-sulphonatophkenyl)porphinatoir(III), FeIII(TSPP); and tetrakis(4-carboxylatophenyl)porphinatoiron(III), FeIII(TCPP), over a wide pH range. The anionic complexes FeIII (TSPP) and FeIII (TCPP) contain high-spin iron(III) at all pHs. Both these complexes exhibit marked spectral changes at ca. pH 6 which correspond to conversion from the diaquo species, in acid solution, to hydroxy- or mu-oxo dimer complexes. Both cationic complexes show similar diaquo to high-spin hydroxy, or mu-oxo dimer, transitions at ca. pH 6. However, at pH > 11.5 for FeIII (T4MPyP) and pH > 9 for FeIII (T2MPyP) a second equilibrium process is observed, leading to two new species. One of these is readily assigned as the low-spin iron(III) dihydroxy complex by analogy with spectra of the dicyano complex. The second species is assigned to the hydroxy iron(II) complex by comparison with photo-chemically generated FeII (T4MPyP) (OH). The formation of iron(II) species in alkaline solutions of FeIII (T4MPyP) and FeIII (T2MPyP) is entirely unexpected and the significance of the observation to previous investigations of the pH-dependent behaviour of these complexes is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cure of polydicyclopentadiene conducted by ring-opening metathesis polymerisation in the presence of a Grubbs catalyst was studied using non-invasive Raman spectroscopy. The spectra of the monomer precursor and polymerised product were fully characterised and all stages of polymerisation monitored. Because of the monomer's high reactivity, the cure process is adaptable to reaction injection moulding and reactive rotational moulding. The viscosity of the dicyclopentadiene undergoes a rapid change at the beginning of the polymerisation process and it is critical that the induction time of the viscosity increase is determined and controlled for successful manufacturing. The results from this work show non-invasive Raman spectroscopic monitoring to be an effective method for monitoring the degree of cure, paving the way for possible implementation of the technique as a method of real-time analysis for control and optimisation during reactive processing. Agreement is shown between Raman measurements and ultrasonic time of flight data acquired during the initial induction period of the curing process. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The feasibility of apertureless scanning near-field Raman microscopy, exploiting the local enhancement in Raman scattering in the vicinity of a silver or gold tip, was investigated. Using the finite difference time domain method we calculated the enhancement of electric field strength, and hence Raman scattering, achieved through the resonant excitation of local modes in the tip. By modelling the frequency-dependent dielectric response of the metal tip we were able to highlight the resonant nature of the tip-enhancement and determine the excitation wavelength required for the strongest electric field enhancement, and hence Raman scattering intensity, which occurs for the excitation of modes localized at the tip apex. It is demonstrated that a peak Raman enhancement of 10(7)-fold should be achievable with <5 nm spatial resolution. We show that surface-enhanced Raman scattering from carbon contamination on a silver or gold tip can be significant. However, we find for a tip of radius of curvature 20 nm that the Raman enhancement should decay totally within 20 nm from the tip. Hence withdrawal of the tip by this distance should lead to the disappearance of the tip-enhanced signal, leaving only that from carbon contamination on the tip itself and the intrinsic signal from the sample. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quantitative monitoring of a mechanochemical reaction by Raman spectroscopy leads to a surprisingly straightforward second-order kinetic model in which the rate is determined simply by the frequency of reactive collisions between reactant particles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chili powder is a globally traded commodity which has been found to be adulterated with Sudan dyes from 2003 onwards. In this study, chili powders were adulterated with varying quantities of Sudan I dye (0.1-5%) and spectra were generated using near infrared reflectance spectroscopy (NIRS) and Raman
spectroscopy (on a spectrometer with a sample compartment modified as part of the study). Chemometrics were applied to the spectral data to produce quantitative and qualitative calibration models and prediction statistics. For the quantitative models coefficients of determination (R2) were found to be
0.891-0.994 depending on which spectral data (NIRS/Raman) was processed, the mathematical algorithm used and the data pre-processing applied. The corresponding values for the root mean square error of calibration (RMSEC) and root mean square error of prediction (RMSEP) were found to be 0.208-0.851%
and 0.141-0.831% respectively, once again depending on the spectral data and the chemometric treatment applied to the data. Indications are that the NIR spectroscopy based models are superior to the models produced from Raman spectral data based on a comparison of the values of the chemometric
parameters. The limit of detection (LOD) based on analysis of 20 blank chili powders against each calibration model gave 0.25% and 0.88% for the NIR and Raman data, respectively. In addition, adopting a qualitative approach with the spectral data and applying PCA or PLS-DA, it was possible to discriminate
between adulterated chili powders from non-adulterated chili powders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

With increasing excitation wavelength from 514 to 782 nm, a significant difference in the Raman spectra of SiC nanorods was observed as compared to bulk material. The intensity ratio of the LO mode to that of the IF mode increases with the excitation wavelength increasing. This has been identified as resonant Raman scattering caused by Fröhlich interaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Raman spectra of carbon nanotubes prepared by catalytic (C-CNT) and d.c. arc discharge (D-CNT) methods are reported. A previously unnoticed third-order Raman peak at ca. 4248 cm-1 was observed in the Raman spectrum of D-CNT. The Raman features of D-CNT and C-CNT are similar to those of highly oriented pyrolytic graphite (HOPG) and active carbon, respectively. The data also suggest that the increase in disorder in D-CNT compared with HOPG is due to structural defects in D-CNT. © 1997 by John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The potential of IR absorption and Raman spectroscopy for rapid identification of novel psychoactive substances (NPS) has been tested using a set of 221 unsorted seized samples suspected of containing NPS. Both IR and Raman spectra showed large variation between the different sub-classifications of NPS and smaller, but still distinguishable, differences between closely related compounds within the same class. In initial tests, screening the samples using spectral searching against a limited reference library allowed only 41% of the samples to be fully identified. The limiting factor in the identification was the large number of active compounds in the seized samples for which no reference vibrational data were available in the libraries rather than poor spectral quality. Therefore, when 33 of these compounds were independently identified by NMR and mass spectrometry and their spectra used to extend the libraries, the percentage of samples identified by IR and Raman screening alone increased to 76%, with only 7% of samples having no identifiable constituents. This study, which is the largest of its type ever carried out, therefore demonstrates that this approach of detecting non-matching samples and then identifying them using standard analytical methods has considerable potential in NPS screening since it allows rapid identification of the constituents of the majority of street quality samples. Only one complete feedback cycle was carried out in this study but there is clearly the potential to carry out continuous identification/updating when this system is used in operational settings.