116 resultados para HE IMPLANTATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reported are total, absolute charge-exchange cross sections for collisions of 3He(2+) ions with He and H-2. Measurements are reported at fixed energies between 0.33 and 4.67 keV/amu. Both the present results and earlier results of others are analyzed in terms of available experimental small-angle differential cross sections as a function of collision energy, and hence the geometry of the exit aperture of the gas-collision cells used by the various experimental groups. In addition, the effective length of gas-collision cells is studied using fluid dynamic and molecular flow simulations to address the density patterns near the cell entrance and exit apertures. When small acceptance-angle corrections were applied, the results of present and previous measurements for the single electron capture in these systems were brought into good accord in the relevant energy ranges. Taken in their entirety, the present data for 3He(2+) with He and H-2 lend themselves to new theoretical calculations of the multichannel charge-exchange cross sections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We determine generalized cross sections for two-photon double ionization of He in the photon energy region between 40.7 and 47 eV where absorption of two photons can lead to non-sequential double ionization only. The present cross sections, obtained in R-matrix Floquet theory, agree with cross sections obtained from time-dependent calculations. By examining the ratio of two-photon double ionization to two-photon single ionization, we demonstrate that core excitation effects at an intensity of 10(13) W cm(-2) are relatively unimportant at 45 eV, but that they are significant at other photon energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescence yields are reported for 3lnl' Rydberg series members in He-like ions of N, O and Ne. Results are presented for singlet series members with n values between 3 and 9, i.e. up to the region of overlap with the states belonging to the 4l4l' manifold in these atoms. This data is required, for example, for the interpretation of charge-exchange experiments involving bare N, O and Ne nuclei. Fluorescence yields, averaged over all 3lnl' singlet states, larger than 50% are obtained from about n = 7.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electronic stopping power of H and He moving through gold is obtained to high accuracy using time-evolving density-functional theory, thereby bringing usual first principles accuracies into this kind of strongly coupled, continuum nonadiabatic processes in condensed matter. The two key unexplained features of what observed experimentally have been reproduced and understood: (i)The nonlinear behavior of stopping power versus velocity is a gradual crossover as excitations tail into the d-electron spectrum; and (ii)the low-velocity H/He anomaly (the relative stopping powers are contrary to established theory) is explained by the substantial involvement of the d electrons in the screening of the projectile even at the lowest velocities where the energy loss is generated by s-like electron-hole pair formation only. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Preparation for Practice module at the University of Ulster is delivered to 170 first year students via a collaborative arrangement between higher and further education institutions. In each of the five sites, students receive large group and small group teaching facilitated by social work training agency workers and academic tutor dyads. An evaluation of the module sought the perceptions of the agency and academic facilitators regarding the overall collaborative arrangement and the model of co-teaching involving social work academics and agency partners. Respondents were asked to complete a semi-structured questionnaire, which generated data from a Likert scale and also invited qualitative commentary. The Likert scale data were analysed via SPSS and the qualitative information was scrutinised using a manual thematic analysis technique. Findings indicated that continuous communication, consistency in programme content and the acknowledgement of the differences in organisation resources were key to a successful collaborative arrangement. It was also noted that a co-teaching model should be viewed as a positive vehicle for achieving module objectives in a safe learning environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-linearities in the electronic stopping power of light projectiles in bulk Al and LiF are addressed from first principles using time-evolving time-dependent density functional theory. In the case of Al, the agreement of the calculations with experiments for H and He projectiles is fair, but a recently observed transition for He from one value of the electronic friction coefficient to a higher value at v ~ 0.3 a.u. is not reproduced by the calculations. For LiF, better accuracy is obtained as compared with previously published simulations, albeit the threshold remains overestimated. © 2013 Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radical cations He-2(+) (H2O)(2)(+), and (NH3)(2)(+) with two-center three-electron A-A bonds are investigated at the configuration interaction (CI), accurate Kohn-Sham (KS), generalized gradient approximation (GGA), and meta-GGA levels. Assessment of seven different GGA and six meta-GGA methods shows that the A(2)(+) systems remain a difficult case for density functional theory (DFT). All methods tested consistently overestimate the stability of A(2)(+): the corresponding D-e errors decrease for more diffuse valence densities in the series He-2(+) > (H2O)(2)(+) > (NH3)(2)(+). Upon comparison to the energy terms of the accurate Kohn-Sham solutions, the approximate exchange functionals are found to be responsible for the errors of GGA-type methods, which characteristically overestimate the exchange in A(2)(+). These so-called exchange functionals implicitly use localized holes. Such localized holes do occur if there is left-right correlation, i.e., the exchange functionals then also describe nondynamical correlation. However, in the hemibonded A(2)(+) systems the typical molecular (left-right, nondynamical) correlation of the two-electron pair bond is absent. The nondynamical correlation built into the exchange functionals is then spurious and yields too low energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Herbig Ae/Be stars are intermediate mass pre-main sequence stars that bridge the gap between the low mass T Tauri stars and the Massive Young Stellar Objects. In this mass range, the acting star forming mechanism switches from magnetically controlled accretion to an as yet unknown mechanism, but which is likely to be direct disk accretion onto the star. We observed a large sample of Herbig Ae/Be stars with X-shooter to address this issue from a multi-wavelength perspective. It is the largest such study to date, not only because of the number of objects involved, but also because of the large wavelength coverage from the blue to the near-infrared. This allows many accretion diagnostics to be studied simultaneously. By correlating the various properties with mass, temperature and age, we aim to determine where and whether the magnetically controlled mass accretion mechanism halts and the proposed direct disk accretion takes over. Here, we will give an overview of the background, present some observations and discuss our initial results. We will introduce a new accretion diagnostic for the research of Herbig Ae/Be stars, the HeI 1.083 µm line. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have carried out optical Thomson scattering measurements from a laser induced breakdown in He at 1 atmosphere. The breakdown was created with a Nd:YAG laser with 9ns pulse duration and 400mJ pulse energy focused into a chamber filled with He. A second harmonic Nd: YAG laser with 9ns pulses and up to 80mJ energy was used to obtain temporally and spatially resolved data on the electron density and temperature. In parallel experiments, we measured the emission of the 447.1nm line from He I. Initial results suggest good agreement between densities inferred but full Abel inversion is needed for conclusive results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.

PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.

RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.

CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To evaluate the outcome of Baerveldt implantation with adjunctive mitomycin-C in cases of complicated glaucoma. PATIENTS AND METHODS: The authors reviewed the charts of all patients who had undergone Baerveldt implantation with mitomycin-C between January 1993 and March 1995. Success was defined before data collection as an intraocular pressure (IOP) between 5 and 21 mm Hg, with or without medications. The success rate was calculated using the Kaplan-Meier actuarial method. RESULTS: Twenty-nine patients were identified. The mean preoperative IOP was 33.6 mm Hg, with an average of 2.0 antiglaucoma medications. The probability of success at 6 and 12 months for patients who received mitomycin-C during Baerveldt implantation was 82.4% and 73.3%, respectively. Choroidal effusion with a flat anterior chamber (10.3%), corneal edema (6.8%), and conjunctival erosion (6.8%) were the most frequent complications. CONCLUSION: In this retrospective series of complicated glaucoma, the implantation of a Baerveldt drainage device with adjunctive mitomycin-C had a satisfactory outcome. The complications encountered and the clinical efficacy were comparable to those of previously reported series in which mitomycin-C was not used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the outcome of combined mitomycin-C filtering surgery, phacoemulsification, and foldable intraocular lens (IOL) implantation. Setting: Wills Eye Hospital, Thomas Jefferson University, Philadelphia, Pennsylvania, USA. Methods: This retrospective study evaluated 182 eyes of 174 patients who had combined mitomycin-C trabeculectomy, phacoemulsification, and insertion of a foldable IOL through a 3.5 mm incision. Success of the combined procedure was defined as intraocular pressure (IOP) below 21 mm Hg, with or without medications, and no serious complication. Success rates were calculated using the Kaplan-Meier actuarial method. Results: Mean follow-up was 16.7 months ± 5.4 (SD). The probability of success at 6, 12, 18, and 24 months was 98.3, 95.6, 90.6, and 88.0%, respectively. When compared with preoperativety, visual acuity improved one or more lines in 148 eyes (81.3%) and worsened one or more lines in 15 (8.2%); 111 eyes (61.0%) achieved visual acuity of 20/40 or better. The most frequent complication was posterior capsule opacification requiring capsulotomy, which occurred in 22 cases (12.0%). Conclusion: The 1 year and 2 year IOP control rate of combined mitomycin-C filtering procedures and phacoemulsification in glaucoma patients was high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the efficacy and safety of intraoperative mitomycin C (MMC) in eyes undergoing Ahmed Glaucoma Valve implantation. Design Randomized controlled clinical trial. Participants Sixty patients with refractory glaucoma. Intervention Sixty eyes of 60 patients with refractory glaucoma were randomized to receive intraoperative MMC (0.5 mg/ml for 5 minutes) (n = 34) or balanced salt solution (n = 26) during Ahmed Glaucoma Valve implantation. Main outcome measures Surgical success was defined according to 2 different criteria: (1) postoperative intraocular pressure (IOP) between 6 and 21 mmHg, with or without antiglaucoma medications, and (2) IOP reduction of at least 30% relative to preoperative values. Eyes requiring additional glaucoma surgery, developing phthisis, or showing loss of light perception were classified as failures. Success rates in both groups were compared using Kaplan-Meier survival curves and the log rank test. Other outcome measures were mean IOP, number of glaucoma medications, and complications. Results After a mean follow-up of 12.3 months, Kaplan-Meier survival analysis showed a probability of success of 59% at 18 months for the MMC group and 61% for the control group when the first criterion for success was used (IOP between 6 and 21 mmHg). When an IOP reduction of at least 30% was used as the criterion to define success, the Kaplan-Meier survival analysis demonstrated a probability of success at 18 months of 62% for the MMC group and 67% for the control group. There were no significant differences in survival rates between the 2 groups with either criterion (P = 0.75 and P = 0.37, respectively). After 15 days postoperatively, the mean IOP did not significantly differ for both MMC and control eyes. Mean numbers of postoperative antiglaucoma medications were similar in MMC-treated eyes and controls. There was no significant difference between the incidences of postoperative complications in both groups. Conclusion Mitomycin C did not increase the short- or intermediate-term success rates of Ahmed Glaucoma Valve implantation. © 2004 by the American Academy of Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care.

METHODS/DESIGN: EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate.

TRIAL REGISTRATION: ISRCTN44464607.