149 resultados para Off-grid
Resumo:
This paper proposes new direct power control (DPC) strategies for three-phase DC/AC converters with improved dynamic response and steady-state performance. As with an electrical machine, source and converter flux which equal the integration of the respective source and converter voltage are used to define active and reactive power flow. Optimization of the look-up-table used in conventional DPC is outlined first, to improve the power control and reduce the current distortion. Then constant switching frequency DPC is developed where the required converter voltage vector within a fixed half switching period is calculated directly from the active and reactive power errors. Detailed angle compensation due to the finite sampling frequency and the use of integral controller to further improve the power control accuracy, are described. Both simulation and experimental results are used to compare conventional DPC and vector control, and to demonstrate the effectiveness and robustness of the proposed control strategies during active and reactive power steps, and line inductance variations.
Resumo:
This paper investigates the control and operation of doubly-fed induction generator (DFIG) and fixed-speed induction generator (FSIG) based wind farms under unbalanced grid conditions. A DFIG system model suitable for analyzing unbalanced operation is developed, and used to assess the impact of an unbalanced supply on DFIG and FSIG operation. Unbalanced voltage at DFIG and FSIG terminals can cause unequal heating on the stator windings, extra mechanical stresses and output power fluctuations. These problems are particularly serious for the FSIG-based wind farm without a power electronic interface to the grid. To improve the stability of a wind energy system containing both DFIG and FSIG based wind farms during network unbalance, a control strategy of unbalanced voltage compensation by the DFIG systems is proposed. The DFIG system compensation ability and the impact of transmission network impedance are illustrated. The simulation results implemented in Matlab/Simulink show that the proposed DFIG control system improves not only its own performance, but also the stability of the FSIG system with the same grid connection point during network unbalance.
Resumo:
This paper proposes a decoupled fault ride-through strategy for a doubly fed induction generator (DFIG) to enhance network stability during grid disturbances. The decoupled operation proposes that a DFIG operates as an induction generator (IG) with the converter unit acting as a reactive power source during a fault condition. The transition power characteristics of the DFIG have been analyzed to derive the capability of the proposed strategy under various system conditions. The optimal crowbar resistance is obtained to exploit the maximum power capability from the DFIG during decoupled operation. The methods have been established to ensure proper coordination between the IG mode and reactive power compensation from the grid-side converter during decoupled operation. The viability and benefits of the proposed strategy are demonstrated using different test network structures and different wind penetration levels. Control performance has been benchmarked against existing grid code standards and commercial wind generator systems, based on the optimal network support required (i.e., voltage or frequency) by the system operator from a wind farm installed at a particular location.
Resumo:
Something new is happening to reverse the historical trend of skilled Scots moving to London for career progression. The Scottish population of London and the South East is falling and this despite Scots enjoying continued occupational success within the South East labour market. The authors ask why Scots are leaving the UK's main escalator region and then investigate how these migration changes can best be theorised relative to literature on the mobility of the 'new service class'. Building on Fielding's escalator region hypothesis, the authors report on recent research on longer distance flows out of the UK's main escalator region. They advance the critique of the escalator region hypothesis set out by Findlay et al and ask why people would leave a global city offering good opportunities for occupational mobility. Demographic regime change provides only a partial answer. Other explanations can be found in the changing mobilities of the new service class as they engage in what Smith has defined as 'translocal' and 'transnational' urbanism. The authors argue that Scotland's changing relationship with London and the South East may be representative of a wider set of changes in migration linkages between regional economies and global cities.
Resumo:
In this paper, the support for legacy application, which is one of the important advantages of Grid computing, is presented. The ability to reuse existing codes/applications in combination with other Web/Internet technologies, such as Java, makes Grid computing a good choice for developers to wrap existing applications behind Intranet or the Internet. The approach developed can be used for migrating legacy applications into Grid Services, which speeds up the popularization of Grid technology. The approach is illustrated using a case study with detailed description of its implementation step by step. Globus Toolkit is utilized to develop the system.
Resumo:
The propagation of nonlinear dust-lattice waves in a two-dimensional hexagonal crystal is investigated. Transverse (off-plane) dust grain oscillatory motion is considered in the form of a backward propagating wave packet whose linear and nonlinear characteristics are investigated. An evolution equation is obtained for the slowly varying amplitude of the first (fundamental) harmonic by making use of a two-dimensional lattice multiple scales technique. An analysis based on the continuum approximation (spatially extended excitations compared to the lattice spacing) shows that wave packets will be modulationally stable and that dark-type envelope solitons (density holes) may occur in the long wavelength region. Evidence is provided of modulational instability and of the occurrence of bright-type envelopes (pulses) at shorter wavelengths. The role of second neighbor interactions is also investigated and is shown to be rather weak in determining the modulational stability region. The effect of dissipation, assumed negligible in the algebra throughout the article, is briefly discussed.
Resumo:
Objectives: To investigate the knowledge and views of a range of healthcare professionals (consultant paediatricians, general practitioners (GPs), community pharmacists and paediatric nurses) regarding the use of unlicensed/off-label medicines in children and the participation of children in clinical trials.
Methods: A regional study in which a survey instrument with 39 items was issued to 500 randomly selected GPs, all community pharmacists (n?=?512), 50 hospital consultants and 150 paediatric nurses in Northern Ireland.
Results: Approximately half (46.5%) of the 1,212 healthcare professionals approached responded to the questionnaire. The majority of respondents indicated their familiarity with the term unlicensed (82.9%) or off-label (58.6%) prescribing with the most frequently quoted reason for such prescribing being younger age (33.6%). Apart from community pharmacists, most respondents reported having gained their knowledge through personal experience. Even though a large percentage of respondents expressed concerns about the safety (77.8%) or efficacy (87.9%) of unlicensed/off-label prescribing in children, only 30.7% reported informing parents/guardians of these concerns on the use of such medicines in children. In addition, only 56% of respondents believed that unlicensed/off-label medicines should undergo clinical trials in children. Overall, 28.4% of respondents (20.1% of GPs, 41.4% of community pharmacists, 27.7% of paediatric nurses and 94% of consultant paediatricians) indicated their willingness to be actively involved in, and recruit their patients for paediatric clinical research.
Conclusion: The use of unlicensed and off-label medicines remains a major issue in paediatric medicine. Until such times as more licensed medicines are available for children, clear guidance should be developed to allow consistency in practice across the spectrum of healthcare professionals who are involved with such medicines in their routine practice.
Resumo:
In this paper, gain-bandwidth (GB) trade-off associated with analog device/circuit design due to conflicting requirements for enhancing gain and cutoff frequency is examined. It is demonstrated that the use of a nonclassical source/drain (S/D) profile (also known as underlap channel) can alleviate the GB trade-off associated with analog design. Operational transconductance amplifier (OTA) with 60 nm underlap S/D MOSFETs achieve 15 dB higher open loop voltage gain along with three times higher cutoff frequency as compared to OTA with classical nonunderlap S/D regions. Underlap design provides a methodology for scaling analog devices into the sub-100 nm regime and is advantageous for high temperature applications with OTA, preserving functionality up to 540 K. Advantages of underlap architecture over graded channel (GC) or laterally asymmetric channel (LAC) design in terms of GB behavior are demonstrated. Impact of transistor structural parameters on the performance of OTA is also analyzed. Results show that underlap OTAs designed with spacer-to-straggle ratio of 3.2 and operated below a bias current of 80 microamps demonstrate optimum performance. The present work provides new opportunities for realizing future ultra wide band OTA design with underlap DG MOSFETs in silicon-on-insulator (SOI) technology. Index Terms—Analog/RF, double gate, gain-bandwidth product, .