Human Papillomavirus (HPV) related oropharyngeal squamous cell carcinomas (OPSCCs) are reported to have improved prognosis and survival in comparison to other head and neck squamous cell cancers (HNSCCs). This systematic review and meta-analysis examines survival differences in HPV-positive HNSCC and OPSCC subtypes including tonsillar carcinoma in studies not previously investigated. Four electronic databases were searched from their inception till April 2011. A random effects meta-analysis was used to pool study estimates evaluating disease-specific (death from HNSCC), overall (all-cause mortality), progression-free and disease-free (recurrence free) survival outcomes in HPV-positive vs. HPV-negative HNSCCs. All statistical tests were two-sided. Forty-two studies were included. Patients with HPV-positive HNSCC had a 54% better overall survival compared to HPV-negative patients HR 0.46 (95% CI 0.37-0.57); the pooled HR for tonsillar cancer and OPSCC was 0.50 (95% CI 0.33-0.77) and HR 0.47 (95% CI 0.35-0.62) respectively. The pooled HR for disease specific survival was 0.28 (95% CI 0.19-0.40); similar effect sizes were found irrespective of the adjustment for confounders, HPV detection methods or study location. Both progression-free survival and disease-free survival were significantly improved in HPV-positive HNSCCs. HPV-positive HNSCCs and OPSCCs patients have a significantly lower disease specific mortality and are less likely to experience progression or recurrence of their cancer than HPV-negative patients; findings which have connotations for treatment selection in these patients.
Resumo:
This paper investigates the implementation of a number of circuits used to perform a high speed closest value match lookup. The design is targeted particularly for use in a search trie, as used in various networking lookup applications, but can be applied to many other areas where such a match is required. A range of different designs have been considered and implemented on FPGA. A detailed description of the architectures investigated is followed by an analysis of the synthesis results. © 2006 IEEE.
Resumo:
Security devices are vulnerable to Differential Power Analysis (DPA) that reveals the key by monitoring the power consumption of the circuits. In this paper, we present the first DPA attack against an FPGA implementation of the Camellia encryption algorithm with all key sizes and evaluate the DPA resistance of the algorithm. The Camellia cryptographic algorithm involves several different key-dependent intermediate operations including S-Box operations. In previous research, it was believed that the Camellia is stronger than AES due to the additional Whitening phase protecting the S-Box operation. However, we propose an attack that bypasses the Whitening phase and targets the S-Box. In this paper, we also discuss a lowcost countermeasure strategy to protect the Pre-whitening / Post-whitening and FL function of Camellia using Dual-rail Precharged Logic and to protect against attacks of the S-Box using Random Delay Insertion. © 2009 IEEE.
Resumo:
This paper describes how worst-case error analysis can be applied to solve some of the practical issues in the development and implementation of a low power, high performance radix-4 FFT chip for digital video applications. The chip has been fabricated using a 0.6 µm CMOS technology and can perform a 64 point complex forward or inverse FFT on real-time video at up to 18 Megasamples per second. It comprises 0.5 million transistors in a die area of 7.8×8 mm and dissipates 1 W, leading to a cost-effective silicon solution for high quality video processing applications. The analysis focuses on the effect that different radix-4 architectural configurations and finite wordlengths has on the FFT output dynamic range. These issues are addressed using both mathematical error models and through extensive simulation.
Resumo:
This study was carried out to investigate whether the electronic portal imaging (EPI) acquisition process could be optimized, and as a result tolerance and action levels be set for the PIPSPro QC-3V phantom image quality assessment. The aim of the optimization process was to reduce the dose delivered to the patient while maintaining a clinically acceptable image quality. This is of interest when images are acquired in addition to the planned patient treatment, rather than images being acquired using the treatment field during a patient's treatment. A series of phantoms were used to assess image quality for different acquisition settings relative to the baseline values obtained following acceptance testing. Eight Varian aS500 EPID systems on four matched Varian 600C/D linacs and four matched Varian 2100C/D linacs were compared for consistency of performance and images were acquired at the four main orthogonal gantry angles. Images were acquired using a 6 MV beam operating at 100 MU min(-1) and the low-dose acquisition mode. Doses used in the comparison were measured using a Farmer ionization chamber placed at d(max) in solid water. The results demonstrated that the number of reset frames did not have any influence on the image contrast, but the number of frame averages did. The expected increase in noise with corresponding decrease in contrast was also observed when reducing the number of frame averages. The optimal settings for the low-dose acquisition mode with respect to image quality and dose were found to be one reset frame and three frame averages. All patients at the Northern Ireland Cancer Centre are now imaged using one reset frame and three frame averages in the 6 MV 100 MU min(-1) low-dose acquisition mode. Routine EPID QC contrast tolerance (+/-10) and action (+/-20) levels using the PIPSPro phantom based around expected values of 190 (Varian 600C/D) and 225 (Varian 2100C/D) have been introduced. The dose at dmax from electronic portal imaging has been reduced by approximately 28%, and while the image quality has been reduced, the images produced are still clinically acceptable.
Resumo:
The general properties of a frequency selective surface loaded with negative impedance converter (NIC)-based active loads are discussed from a theoretical perspective.The stability problem associated with NIC circuits embedded in artificial magnetic conductor (AMC) and AMC absorber applications is studied using pole-zero analysis. The requirements and constraints for achieving stable operation with enhanced bandwidth using negative capacitance as realized by a floating NIC network are derived. Furthermore, it is shown that it is nearly impossible to simultaneously implement a negative capacitor and a negative inductor to such structures. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:2111–2114, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.27019
Resumo:
There is substantial international variation in human papillomavirus (HPV) prevalence; this study details the first report from Northern Ireland and additionally provides a systematic review and meta-analysis pooling the prevalence of high-risk (HR-HPV) subtypes among women with normal cytology in the UK and Ireland. Between February and December 2009, routine liquid based cytology (LBC) samples were collected for HPV detection (Roche Cobas® 4800 [PCR]) among unselected women attending for cervical cytology testing. Four electronic databases, including MEDLINE, were then searched from their inception till April 2011. A random effects meta-analysis was used to calculate a pooled HR-HPV prevalence and associated 95% confidence intervals (CI). 5,712 women, mean age 39 years (±SD 11.9 years; range 20-64 years), were included in the analysis, of which 5,068 (88.7%), 417 (7.3%) and 72 (1.3%) had normal, low, and high-grade cytological findings, respectively. Crude HR-HPV prevalence was 13.2% (95% CI, 12.7-13.7) among women with normal cytology and increased with cytological grade. In meta-analysis the pooled HR-HPV prevalence among those with normal cytology was 0.12 (95% CIs, 0.10-0.14; 21 studies) with the highest prevalence in younger women. HPV 16 and HPV 18 specific estimates were 0.03 (95% CI, 0.02-0.05) and 0.01 (95% CI, 0.01-0.02), respectively. The findings of this Northern Ireland study and meta-analysis verify the prevalent nature of HPV infection among younger women. Reporting of the type-specific prevalence of HPV infection is relevant for evaluating the impact of future HPV immunization initiatives, particularly against HR-HPV types other than HPV 16 and 18. J. Med. Virol. 85:295-308, 2013. © 2012 Wiley Periodicals, Inc. Copyright © 2012 Wiley Periodicals, Inc.
Resumo:
In order to formalize and extend on previous ad-hoc analysis and synthesis methods a theoretical treatment using vector representations of directional modulation (DM) systems is introduced and used to achieve DM transmitter characteristics. An orthogonal vector approach is proposed which allows the artificial orthogonal noise concept derived from information theory to be brought to bear on DM analysis and synthesis. The orthogonal vector method is validated and discussed via bit error rate (BER) simulations.