79 resultados para live coding


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A very high-quality sub-band ADPCM music coding scheme which compresses high-fidelity music signals, bandlimited to 15kHz, to an equivalent PCM representation of only 4 bits per sample, is described. By processing music sampled at 32 kHz, this coder exhibits a total bit rate of only 128kbit/s and is consequently applicable to the ISDN. Subjective tests conducted with this coder have shown that music recovered from the compression scheme is essentially indistinguishable from the original material. The results obtained are of major importance, not only for ISDN and broadcasting, but also for other digital audio technology such as compact disc (CD) and digital audio tape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of high-performance VLSI architectures for real-time image coding applications are described. In particular, attention is focused on circuits for computing the 2-D DCT (discrete cosine transform) and for 2-D vector quantization. The former circuits are based on Winograd algorithms and comprise a number of bit-level systolic arrays with a bit-serial, word-parallel input. The latter circuits exhibit a similar data organization and consist of a number of inner product array circuits. Both circuits are highly regular and allow extremely high data rates to be achieved through extensive use of parallelism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subjective performance of the G. 722 7-kHz wideband speech coding recommendation using music signals is described. A number of audible distortions specific to music signals were found to be present in real-time evaluations of the coder. As a result, three modifications are proposed which are found to improve the performance for music signals. These modifications are compatible with the G. 722 system configuration. Modifications made to G. 722 to alleviate the most serious aspects of the noise modulation are described: (1) an adaptive bit allocation scheme is used to reduce short and long-term nonoptimality; (2) spectral noise shaping is incorporated, significantly enhancing the subjective performance of certain modes; and (3) backward block adaptive prediction is used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subjective performance of the G. 722 7-kHz wideband speech-coding recommendation using music signals is described. A number of audible distortions specific to music signals were found to be present in real-time evaluations of the coder. As a result, three modifications are proposed which are found to improve the performance for music signals. These modifications are compatible with the G. 722 system configuration. The results obtained clearly demonstrate the very high coding efficiency of subband ADPCM (adaptive differential pulse-code modulation) with comparison to digitally companding and ADM schemes when applied to music signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Live projects adopt a wide range of approaches: design/ build, community engagement, participation, protest, analysis, etc. They are driven by tutors with passion, expertise and the ability to manage risk, in ways that exhibit fluency and high levels of skill. They also offer sites of student-led and community co-learning, can support research, demonstrate ‘impact’ and satisfy universities’ policies on outreach. Whilst the breadth and reach of Live Projects is now demonstrably wide, we still fail to fully locate Live Projects within a pedagogical context, tending instead to limit our descriptions and hence analysis to the architectural process and outcome. This failure to locate Live Projects within a pedagogical framework means we still struggle to encapsulate, critique, progress, and indeed, elevate the work.

This chapter draws on some of the case studies presented in recent papers and international conferences in order to provide educators with signposts and important overviews around which and in respect to they can develop their own pedagogical frameworks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to: (1). evaluate the validity of the Neonatal Facial Coding System (NFCS) for assessment of postoperative pain and (2). explore whether the number of NFCS facial actions could be reduced for assessing postoperative pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessment of infant pain is a pressing concern, especially within the context of neonatal intensive care where infants may be exposed to prolonged and repeated pain during lengthy hospitalization. In the present study the feasibility of carrying out the complete Neonatal Facial Coding System (NFCS) in real time at bedside, specifically reliability, construct and concurrent validity, was evaluated in a tertiary level Neonatal Intensive Care Unit (NICU). Heel lance was used as a model of procedural pain, and observed with n = 40 infants at 32 weeks gestational age. Infant sleep/wake state, NFCS facial activity and specific hand movements were coded during baseline, unwrap, swab, heel lance, squeezing and recovery events. Heart rate was recorded continuously and digitally sampled using a custom designed computer system. Repeated measures analysis of variance (ANOVA) showed statistically significant differences across events for facial activity (P <0.0001) and heart rate (P <0.0001). Planned comparisons showed facial activity unchanged during baseline, swab and unwrap, then increased significantly during heel lance (P <0.0001), increased further during squeezing (P <0.003), then decreased during recovery (P <0.0001). Systematic shifts in sleep/wake state were apparent. Rise in facial activity was consistent with increased heart rate, except that facial activity more closely paralleled initiation of the invasive event. Thus facial display was more specific to tissue damage compared with heart rate. Inter-observer reliability was high. Construct validity of the NFCS at bedside was demonstrated as invasive procedures were distinguished from tactile. While bedside coding of behavior does not permit raters to be blind to events, mechanical recording of heart rate allowed for an independent source of concurrent validation for bedside application of the NFCS scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale: Mesenchymal stem cells secrete paracrine factors that can regulate lung permeability and decrease inflammation, making it a potentially attractive therapy for acute lung injury. However, concerns exist whether mesenchymal stem cells' immunomodulatory properties may have detrimental effects if targeted toward infectious causes of lung injury. Objectives: Therefore, we tested the effect of mesenchymal stem cells on lung fluid balance, acute inflammation, and bacterial clearance. Methods: We developed an Escherichia coli pneumonia model in our ex vivo perfused human lung to test the therapeutic effects of mesenchymal stem cells on bacterial-induced acute lung injury. Measurements and Main Results: Clinical-grade human mesenchymal stem cells restored alveolar fluid clearance to a normal level, decreased inflammation, and were associated with increased bacterial killing and reduced bacteremia, in part through increased alveolar macrophage phagocytosis and secretion of antimicrobial factors. Keratinocyte growth factor, a soluble factor secreted by mesenchymal stem cells, duplicated most of the antimicrobial effects. In subsequent in vitro studies, we discovered that human monocytes expressed the keratinocyte growth factor receptor, and that keratinocyte growth factor decreased apoptosis of human monocytes through AKT phosphorylation, an effect that increased bacterial clearance. Inhibition of keratinocyte growth factor by a neutralizing antibody reduced the antimicrobial effects of mesenchymal stem cells in the ex vivo perfused human lung and monocytes grown in vitro injured with E. coli bacteria. Conclusions: In E. coli-injured human lungs, mesenchymal stem cells restored alveolar fluid clearance, reduced inflammation, and exerted antimicrobial activity, in part through keratinocyte growth factor secretion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diblock copolymer vesicles are tagged with pH-responsive Nile Blue-based labels and used as a new type of pH-responsive colorimetric/fluorescent biosensor for far-red and near-infrared imaging of live cells. The diblock copolymer vesicles described herein are based on poly(2-(methacryloyloxy)ethyl phosphorylcholine-block-2-(diisopropylamino)ethyl methacrylate) [PMPC-PDPA]: the biomimetic PMPC block is known to facilitate rapid cell uptake for a wide range of cell lines, while the PDPA block constitutes the pH-responsive component that enables facile vesicle self-assembly in aqueous solution. These biocompatible vesicles can be utilized to detect interstitial hypoxic/acidic regions in a tumor model via a pH-dependent colorimetric shift. In addition, they are also useful for selective intracellular staining of lysosomes and early endosomes via subtle changes in fluorescence emission. Such nanoparticles combine efficient cellular uptake with a pH-responsive Nile Blue dye label to produce a highly versatile dual capability probe. This is in marked contrast to small molecule dyes, which are usually poorly uptaken by cells, frequently exhibit cytotoxicity, and are characterized by intracellular distributions invariably dictated by their hydrophilic/hydrophobic balance.