116 resultados para false allegation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avermectins are frequently used to control parasitic infestations in many animal species. Previous studies have shown the long-term persistence of unwanted residues of these drugs in animal tissues and fluids. An immunoassay screening test for the detection acid quantification of ivermectin residues in bovine milk has been developed. After an extensive extraction procedure, milk samples were applied to a competitive dissociation-enhanced lanthanide fluoroimmunoassay using a monoclonal antibody against an ivermectin-transferrin conjugate, The monoclonal antibody, raised in Balb C mice, showed cross-reactivity with eprinomectin (92%), abamectin (82%) and doramectin (16%). The limit of detection of the assay (mean + 3 SD), calculated from the analysis of 17 known negative samples, was calculated as 4.6 ng/mL. Intra- and inter-assay RSDs were determined as 11.6% and 15.8%, respectively, using a negative bovine milk sample fortified with 25 ng/mL ivermectin. Six Friesian milking cows were treated with ivermectin, three with a pour-on formulation of the drug and three with an injectable solution at the manufacturer's recommended dose rate. An initial mean peak in ivermectin residue concentration was detected at day 4 (mean level = 47.5 ng/mL) and day 5 post-treatment (mean level = 26.4 ng/mL) with the injectable form and pour-on treatment, respectively. A second peak in residue concentration was observed using the DELFIA(R) procedure 28 days post-treatment in both treatment groups (23.1 ng/mL injectable and 51.9 ng/mL pour-on). These second peaks were not confirmed by HPLC and must at this Lime be considered to be false-positive results. By day 35 after treatment the mean ivermectin residue concentration of both groups fell below the limit of detection of the assay. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

19-Nortestosterone (beta-NT) is banned for use as a growth promoter in food animals within the European Union. For regulatory control purposes, urine and bile samples are routinely screened by immunoassay. The aim of the present study was to compare the ability of two immunoassays, using two rabbit polyclonal antibodies raised against two different NT derivatives, to detect NT residues in bovine bile. One antiserum cross-reacted with both alpha-NT and beta-NT (alpha/beta-NT), whereas the other was specific for alpha-NT. Bile samples from 266 slaughtered cattle were deconjugated and analyzed using both antibodies, with all screening positives (>2 ng ml(-1)) confirmed by high resolution gas chromatography mass spectrometry. The alpha/beta-NT and alpha-NT antibody-based ELISAs screened 39 and 44 samples positive, respectively, with NT confirmed in 22 and 39, respectively. The alpha/beta-NT antibody-based ELISA produced a false-negative rate of 44% compared to 0% for the alpha-NT antibody-based ELISA. Supplementary investigations concluded that a matrix effect was a major cause of the marked differences in false-negative rates. This result underlines the necessity to validate immunoassays in the sample matrix.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relationship between changes in retinal vessel morphology and the onset and progression of diseases such as diabetes, hypertension and retinopathy of prematurity (ROP) has been the subject of several large scale clinical studies. However, the difficulty of quantifying changes in retinal vessels in a sufficiently fast, accurate and repeatable manner has restricted the application of the insights gleaned from these studies to clinical practice. This paper presents a novel algorithm for the efficient detection and measurement of retinal vessels, which is general enough that it can be applied to both low and high resolution fundus photographs and fluorescein angiograms upon the adjustment of only a few intuitive parameters. Firstly, we describe the simple vessel segmentation strategy, formulated in the language of wavelets, that is used for fast vessel detection. When validated using a publicly available database of retinal images, this segmentation achieves a true positive rate of 70.27%, false positive rate of 2.83%, and accuracy score of 0.9371. Vessel edges are then more precisely localised using image profiles computed perpendicularly across a spline fit of each detected vessel centreline, so that both local and global changes in vessel diameter can be readily quantified. Using a second image database, we show that the diameters output by our algorithm display good agreement with the manual measurements made by three independent observers. We conclude that the improved speed and generality offered by our algorithm are achieved without sacrificing accuracy. The algorithm is implemented in MATLAB along with a graphical user interface, and we have made the source code freely available. 

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Narrative, by its very nature, is changing as a consequence of internet developments. Hypertexts are, for example, changing not just the way in which we disseminate information, but also the ways in which we write, speak and think. In this paper a narrative approach is taken to assess a case study of a person’s extensive home site on the web. Bill maintains an extensive web site documenting his life with Parkinson’s Disease, his love for running and all matters relating to the island of Montserrat in the Eastern Caribbean. Bill’s Parkinson’s Disease hypertext diary forms the focus of this case study of a life spent on-line. Though set up just as a diary about this progressively degenerative disease, because of its hypertextual qualities, this paper argues that it is through the diary that Bill comes to produce and sustain - to narrate - his identity. This paper thus contributes to the position that though hypertext encourages the construction of fragmented and false identity narratives, it is also a medium for sustaining linear and coherent representations of self-identity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Motivated by the need to solve ecological problems (climate change, habitat fragmentation and biological invasions), there has been increasing interest in species distribution models (SDMs). Predictions from these models inform conservation policy, invasive species management and disease-control measures. However, predictions are subject to uncertainty, the degree and source of which is often unrecognized. Here, we review the SDM literature in the context of uncertainty, focusing on three main classes of SDM: niche-based models, demographic models and process-based models. We identify sources of uncertainty for each class and discuss how uncertainty can be minimized or included in the modelling process to give realistic measures of confidence around predictions. Because this has typically not been performed, we conclude that uncertainty in SDMs has often been underestimated and a false precision assigned to predictions of geographical distribution. We identify areas where development of new statistical tools will improve predictions from distribution models, notably the development of hierarchical models that link different types of distribution model and their attendant uncertainties across spatial scales. Finally, we discuss the need to develop more defensible methods for assessing predictive performance, quantifying model goodness-of-fit and for assessing the significance of model covariates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An optimised indirect peroxidase-anti-peroxidase immunohistochemical technique was used to detect endogenous biotin in frozen tissue sections from biotin-supplemented and biotin-depleted pigs and chickens. A monoclonal anti-biotin antibody was used as primary antibody in this technique. Immunoreactive biotin was detected in many tissues of both species including liver, kidney, pancreas, adipose tissue, adrenal gland, testis, brain, choroid plexus, cardiac and skeletal muscle, epithelium of the respiratory and digestive systems, skin and lymphoid tissues. The specificity of immunostaining for biotin was confirmed by the finding of reduced staining intensities in tissues of biotin-depleted animals compared to those of biotin-supplemented animals. The results of this study suggest that biotin has metabolic functions in a wider range of tissues than previously known. They also indicate that endogenous tissue biotin should be considered as a source of false positive staining when immunohistochemical or histochemical techniques which use avidin or streptavidin reagents or anti-biotin antibodies as components of the detection system, are applied to tissue sections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many zeranol immunoassay test kits cross-react with toxins formed by naturally occurring Fusarium spp. fungi, leading to false-positive screening results. This paper describes the evaluation and application of recently published, dry reagent time-resolved fluoroimmunoassays (TR-FIA) for zeranol and the toxin alpha-zearalenol. A ring test of bovine urine fortified with zeranol and/or alpha-zearalenol in four European Union National Reference Laboratories demonstrated that the TR-FIA tests were accurate and robust. The alpha-zearalenol TR-FIA satisfactorily quantified alpha-zearalenol in urine fortified at 10-30 ng ml(-1) . The specificity-enhanced zeranol TR-FIA accurately quantified zeranol in the range 2-5 ng ml(-1) and gave no false-positive results in blank urine, even in the presence of 30 ng ml(-1) alpha-zearalenol. Zeranol TR-FIA specificity was demonstrated further by analysing incurred zeranol-free urine samples containing natural Fusarium spp. toxins. The TR-FIA yielded no false-positive results in the presence of up to 22 ng ml(-1) toxins. The performance of four commercially available zeranol immunoassay test kits was more variable. Three kits produced many false-positive results. One kit produced only one potential false-positive using a protocol that was longer than that of the TR-FIA. These TR-FIAs will be valuable tools to develop inspection criteria to distinguish illegal zeranol abuse from contamination arising from in vivo metabolism of Fusarium spp. toxins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensitive and specific monoclonal ELISA for the determination of tissue bound furazolidone metabolite 3-amino-2-oxazolidinone (AOZ) is described. The procedure enables the detection of AOZ in matrix supernatant after homogenisation, protease treatment, acid hydrolysis and derivatisation of AOZ released from the tissue by o-nitrobenzaldehyde. The formed p-nitrophenyl 3-amino-2-oxazolidinone (NPAOZ) is determined by ELISA calibrated with matrix-matched standards in the concentration range of 0.05-5.0 mu g l(-1). The assay was validated according to criteria set down by Commission Decision 2002/657/EC for the performance and validation of analytical methods for chemical residues. Detection capability, set on the basis of acceptance of no false negative results, was 0.4 mu g kg(-1) for shrimp, poultry, beef and pork muscle. This sensitivity approaches the established confirmatory LC-MS/MS able to quantify tissue-bound AOZ at levels as low as 0.3 mu g kg(-1). An excellent correlation of results obtained by ELISA and LC/MS-MS within the concentration range 0-32.1 mu g kg(-1) was found in the naturally contaminated shrimp samples (r = 0.999, n = 8). A similar con-elation was found for the incurred poultry samples within the concentration range of 0-10.5 mu g kg(-1) (r = 0.99, n = 8). (c) 2005 Elsevier B.V All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel technique is described for the identification and quantification of environmental pollutants based on toxicity fingerprinting with a metabolic lux-marked bacterial biosensor. This method involved characterizing the toxicity-based responses of the biosensor to seven calibration pollutants as acute temporal-dose response fingerprints. An algorithm is described to allow comparisons of responses of an unknown pollutant to be made against the calibration data. This is based on predicting pollutant concentration at each of six different time points over the course of a 5-min assay. If the prediction is consistent between the unknown pollutant and a calibration pollutant at the 95% test level, this is considered to be a positive identification. All seven calibration pollutants could be successfully distinguished from each other with this technique. Environmental samples, individually spiked with single concentrations of pollutants, were compared in this way against the calibration pollutants. An 83% identification success was achieved, with no false positives at the 95% test level. This is a simple and rapid technique that potentially can be applied to monitoring of industrial wastewater or as a screening tool for regulators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunomagnetic separation (IMS) can selectively isolate and concentrate Mycobacterium bovis cells from lymph node tissue to facilitate subsequent detection by PCR (IMS-PCR) or culture (IMS-MGIT). This study describes application of these novel IMS-based methods to test for M. bovis in a survey of 280 bovine lymph nodes (206 visibly lesioned (VL), 74 non-visibly lesioned (NVL)) collected at slaughter as part of the Northern Ireland bovine TB eradication programme. Their performance was evaluated relative to culture. Overall, 174 (62.1%) lymph node samples tested positive by culture, 162 (57.8%) by IMS-PCR (targeting IS6110), and 196 (70.0%) by IMS-MGIT culture. Twelve (6.9%) of the 174 culture positive lymph node samples were not detected by either of the IMS-based methods. However, an additional 78 M. bovis positive lymph node samples (26 (12.6%) VL and 54 (73.0%) NVL) were detected by the IMS-based methods and not by culture. When low numbers of viable M. bovis are present in lymph nodes (e.g. in NVLs of skin test reactor cattle) decontamination prior to culture may adversely affect viability, leading to false negative culture results. In contrast, IMS specifically captures whole M. bovis cells (live, dead or potentially dormant) which are not subject to any deleterious treatment before detection by PCR or MGIT culture. During this study only 2.7% of NVL lymph nodes tested culture positive, whereas 73% of the same samples tested M. bovis positive by the IMS-based tests. Results clearly demonstrate that not only are the IMS-based methods more rapid but they have greater detection sensitivity than the culture approach currently used for the detection of M. bovis infection in cattle.. Adoption of the IMS-based methods for lymph node testing would have the potential to improve M. bovis detection in clinical samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dermot Bolger's The Journey Home (1990) narrates an often hyperbolic and overblown diatribe against a litany of social and political ills, which elicited frequently critical responses to the novel from reviewers. Yet Bolger's seminal work remains both popular and controversial because of its capacity to shock and upbraid the false morality of Irish society--a society that the author considered to be riven by class inequalities and official abuses. Bolger employs sexual abuse as a metonym for political corruption in the novel, and this essay explores The Journey Home's surreal story of youth in a working-class Dublin suburb in light of more recent revelations of Ireland's legacy of institutional sexual abuse.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The interleukin 10 knockout mouse (IL10-KO) is a model of human inflammatory bowel disease (IBD) used to Study host microbial interactions and the action of potential therapeutics. Using Affymetrix data analysis, important signaling pathways and transcription factors relevant to gut inflammation and antiinflammatory probiotics were identified.

Methods: Affymetrix microarray analysis on both wildtype (WT) and IL10-KO mice orally administered with and without the probiotic VSL#3 was performed and the results validated by real-time polymerase chain reaction (PCR), immunocytochemistry, proteomics, and histopathology. Changes in metabolically active bacteria were assessed with denaturing gradient gel electrophoresis (DGGE).

Results: Inflammation in IL10-KO mice was characterized by differential regulation of inflammatory, nuclear receptor, lipid, and xenobiotic signaling pathways. Probiotic intervention resulted in downregulation of CXCL9 (fold change [FC] = -3.98, false discovery rate [FDR] = 0.019), CXCL10 (FC = -4.83, FDR = 0.0008), CCL5 (FC -3.47 FDR = 0.017), T-cell activation (Itgal [FC = -4.72, FDR = 0.00009], Itgae [FC = -2.54 FDR = 0.0044]) and the autophagy gene IRGM (FC = -1.94, FDR = 0.01), a recently identified susceptibility gene in human IBD. Consistent with a marked reduction in integrins, probiotic treatment decreased the number of CCL5+ CD3+ double-positive T Cells and upregulated galectin2, which triggers apoptosis of activated T cells. Importantly, genes associated with lipid and PPAR signaling (PPAR alpha [FC = 2.36, FDR = 0.043], PPARGC1 alpha [FC 2.58, FDR = 0.016], Nrld2 [FC = 3.11, FDR = 0.0067]) were also upregulated. Altered microbial diversity was noted in probiotic-treated mice.

Conclusions: Bioinformatics analysis revealed important immune response. phagocytic and inflammatory pathways dominated by elevation of T-helper cell 1 type (TH1) transcription factors in IL10-KO mice. Probiotic intervention resulted in a site-specific reduction of these pathways but importantly upregulated PPAR, xenobiotic, and lipid signaling genes. potential antagonists of NF-kappa B inflammatory pathways.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare time-domain waveform analysis of second-trimester uterine artery Doppler using the resistance index (RI) with waveform analysis using a mathematical tool known as wavelet transform for the prediction of pre-eclampsia (PE). This was a retrospective, nested case-cohort study of 336 women, 37 of whom subsequently developed PE. Uterine artery Doppler waveforms were analysed using both RI and waveform analysis. The utility of these indices in screening for PE was then evaluated using receiver operating characteristic curves. There were significant differences in uterine artery RI between the PE women and those with normal pregnancy outcome. After wavelet analysis, significant difference in the mean amplitude in wavelet frequency band 4 was noted between the 2 groups. The sensitivity for both Doppler RI and frequency band 4 for the detection of PE at a 10% false-positive rate was 45%. This small study demonstrates the application of wavelet transform analysis of uterine artery Doppler waveforms in screening for PE. Further prospective studies are needed in order to clearly define if this analytical approach to waveform analysis may have the potential to improve the detection of PE by uterine artery Doppler screening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conflicting results have been reported on the detection of paramyxovirus transcripts in Paget's disease, and a possible explanation is differences in the sensitivity of RT-PCR methods for detecting virus. In a blinded study, we found no evidence to suggest that laboratories that failed to detect viral transcripts had less sensitive RT-PCR assays, and we did not detect measles or distemper transcripts in Paget's samples using the most sensitive assays evaluated.

Introduction: There is conflicting evidence on the possible role of persistent paramyxovirus infection in Paget's disease of bone (PDB). Some workers have detected measles virus (MV) or canine distemper virus (CDV) transcripts in cells and tissues from patients with PDB, but others have failed to confirm this finding. A possible explanation might be differences in the sensitivity of RT-PCR methods for detecting virus. Here we performed a blinded comparison of the sensitivity of different RT-PCR-based techniques for MV and CDV detection in different laboratories and used the most sensitive assays to screen for evidence of viral transcripts in bone and blood samples derived from patients with PDB.

Materials and Methods: Participating laboratories analyzed samples spiked with known amounts of MV and CDV transcripts and control samples that did not contain viral nucleic acids. All analyses were performed on a blinded basis.

Results: The limit of detection for CDV was 1000 viral transcripts in three laboratories (Aberdeen, Belfast, and Liverpool) and 10,000 transcripts in another laboratory (Manchester). The limit of detection for MV was 16 transcripts in one laboratory (NIBSC), 1000 transcripts in two laboratories (Aberdeen and Belfast), and 10,000 transcripts in two laboratories (Liverpool and Manchester). An assay previously used by a U.S.-based group to detect MV transcripts in PDB had a sensitivity of 1000 transcripts. One laboratory (Manchester) detected CDV transcripts in a negative control and in two samples that had been spiked with MV. None of the other laboratories had false-positive results for MV or CDV, and no evidence of viral transcripts was found on analysis of 12 PDB samples using the most sensitive RT-PCR assays for MV and CDV.

Conclusions: We found that RT-PCR assays used by different laboratories differed in their sensitivity to detect CDV and MV transcripts but found no evidence to suggest that laboratories that previously failed to detect viral transcripts had less sensitive RT-PCR assays than those that detected viral transcripts. False-positive results were observed with one laboratory, and we failed to detect paramyxovirus transcripts in PDB samples using the most sensitive assays evaluated. Our results show that failure of some laboratories to detect viral transcripts is unlikely to be caused by problems with assay sensitivity and highlight the fact that contamination can be an issue when searching for pathogens by sensitive RT-PCR-based techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG).

METHODS: Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model.

RESULTS: Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty.

CONCLUSIONS: No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.