117 resultados para Serum Hormones
Resumo:
Particulate colloids often occur together with proteins in sewage-impacted water. Using Bovine Serum Albumin (BSA) as a surrogate for protein in sewage, column experiments investigating the capacity of iron-oxide coated sands to remove latex microspheres from water revealed that microsphere attenuation mechanisms depended on antecedent BSA coverage. Dual pulse experiment (DPE) results suggested that where all BSA was adsorbed, subsequent multiple pore volume microsphere breakthrough curves reflected progressively reduced colloid deposition rates with increasing adsorbed BSA content. Modelling colloid responses suggested adsorption of 1 µg BSA generated the same response as blockage by between 7.1x108 and 2.3x109 deposited microspheres. By contrast, microsphere responses in DPEs where BSA coverage of the deposition sites approached/ reached saturation revealed the coated sand maintained a finite capacity to attenuate microspheres, even when incapable of further BSA adsorption. Subsequent microsphere breakthrough curves demonstrated the matrix’s colloid attenuation capacity progressively increased with continued microsphere deposition. Experimental findings suggested BSA adsorption on the sand surface approaching/ reaching saturation generated attractive deposition sites for colloids, which became progressively more attractive with further colloid deposition (filter ripening). Results demonstrate that adsorption of a single type of protein may either enhance or inhibit colloid mobility in saturated porous media.
Resumo:
Regulatory authorities, the food industry and the consumer demand reliable determination of chemical contaminants present in foods. A relatively new analytical technique that addresses this need is an immunobiosensor based on surface plasmon resonance (SPR) measurements. Although a range of tests have been developed to measure residues in milk, meat, animal bile and honey, a considerable problem has been encountered with both serum and plasma samples. The high degree of non-specific binding of some sample components can lead to loss of assay robustness, increased rates of false positives and general loss of assay sensitivity. In this paper we describe a straightforward precipitation technique to remove interfering substances from serum samples to be analysed for veterinary anthelmintics by SPR. This technique enabled development of an assay to detect a wide range of benzimidazole residues in serum samples by immunobiosensor. The limit of quantification was below 5 ng/ml and coefficients of variation were about 2%.
Resumo:
In order to assess the rationale and possible indications for the use of recombinant erythropoietin in paroxysmal nocturnal haemoglobinuria (PNH), we have measured endogenous erythropoietin (Epo) levels in 18 patients with PNH and in 44 patients with iron deficiency anaemia (IDA), In both groups of patients we found a significant inverse correlation between Epo and haemoglobin (Hb). However, the mean Epo level was significantly higher in the PNH group (385 mU/ml) than in the IDA group (136 mU/ml), The range of Epo levels at any given Hb was greater in the PNH group than in the IDA group. There was a significant positive correlation between Epo and absolute reticulocyte count, Since Epo administration is unlikely to benefit patients with high levels of endogenous Epo, we conclude that in the majority of patients with PNH there is no indication for treatment with Epo.