80 resultados para Minimum distance
Resumo:
This is a paper about resistance and affordance as they relate to music-making in the most extended sense, and perhaps about empathy if this is understood as a capacity to ‘read’ the resistances and affordances of objects, bodies, people and environments. It proceeds from a set of broad working assumptions which inform one individual’s musical practice, via a description a musical-instrument making project which is a hybrid of physical and virtual elements and is designed to test those assumptions, to a speculative finale in which it is suggested that musicking might, in some circumstances, be regarded in itself as a form of resistance. It moves from the intimate and personal, through what might be regarded as local concerns to more global observation, prefiguring the structure of the performance system it describes: the Virtual-Physical Feedback flute
Resumo:
Although less likely to be reported in clinical trials than expressions of the statistical significance of differences in outcomes, whether or not a treatment has delivered a specified minimum clinically important difference (MCID) is also relevant to patients and their caregivers and doctors. Many dementia treatment randomised controlled trials (RCTs) have not reported MCIDs and, where they have been done, observed differences have not reached these.
Resumo:
To overcome the weak evidence base coming from often poor and insufficient clinical research in older people, a minimum data set to achieve harmonisation is highly advisable. This will lead to uniform nomenclature and to the standardisation of the assessment tools. Our primary objective was to develop a Geriatric Minimum Data Set (GMDS) for clinical research.
Resumo:
In the double-detonation scenario for Type Ia supernovae, it is suggested that a detonation initiates in a shell of helium-rich material accreted from a companion star by a sub-Chandrasekhar-mass white dwarf. This shell detonation drives a shock front into the carbon-oxygen white dwarf that triggers a secondary detonation in the core. The core detonation results in a complete disruption of the white dwarf. Earlier studies concluded that this scenario has difficulties in accounting for the observed properties of Type Ia supernovae since the explosion ejecta are surrounded by the products of explosive helium burning in the shell. Recently, however, it was proposed that detonations might be possible for much less massive helium shells than previously assumed (Bildsten et al.). Moreover, it was shown that even detonations of these minimum helium shell masses robustly trigger detonations of the carbon-oxygen core (Fink et al.). Therefore, it is possible that the impact of the helium layer on observables is less than previously thought. Here, we present time-dependent multi-wavelength radiative transfer calculations for models with minimum helium shell mass and derive synthetic observables for both the optical and ? -ray spectral regions. These differ strongly from those found in earlier simulations of sub-Chandrasekhar-mass explosions in which more massive helium shells were considered. Our models predict light curves that cover both the range of brightnesses and the rise and decline times of observed Type Ia supernovae. However, their colors and spectra do not match the observations. In particular, their B - V colors are generally too red. We show that this discrepancy is mainly due to the composition of the burning products of the helium shell of the Fink et al. models which contain significant amounts of titanium and chromium. Using a toy model, we also show that the burning products of the helium shell depend crucially on its initial composition. This leads us to conclude that good agreement between sub-Chandrasekhar-mass explosions and observed Type Ia supernovae may still be feasible but further study of the shell properties is required.
Resumo:
The explosion of sub-Chandrasekhar mass white dwarfs via the double detonation scenario is a potential explanation for type Ia supernovae. In this scenario, a surface detonation in a helium layer initiates a detonation in the underlying carbon/oxygen core leading to an explosion. For a given core mass, a lower bound has been determined on the mass of the helium shell required for dynamical burning during a helium flash, which is a necessary prerequisite for detonation. For a range of core and corresponding minimum helium shell masses, we investigate whether an assumed surface helium detonation is capable of triggering a subsequent detonation in the core even for this limiting case. We carried out hydrodynamic simulations on a co-expanding Eulerian grid in two dimensions assuming rotational symmetry. The detonations are propagated using the level-set approach and a simplified scheme for nuclear reactions that has been calibrated with a large nuclear network. The same network is used to determine detailed nucleosynthetic abundances in a post-processing step. Based on approximate detonation initiation criteria in the literature, we find that secondary core detonations are triggered for all of the simulated models, ranging in core mass from 0.810 up to 1.385 M? with corresponding shell masses from 0.126 down to 0.0035 M?. This implies that, as soon as a detonation triggers in a helium shell covering a carbon/oxygen white dwarf, a subsequent core detonation is virtually inevitable.
Resumo:
Purpose: The purpose of this study was to evaluate "in vivo" safety of trypan blue (TB) in patients undergoing TB-assisted internal limiting membrane or epiretinal membrane peeling. Methods: Prospective study including 21 patients (21 eyes) with full-thickness macular hole and/or epiretinal membrane undergoing TB-assisted internal limiting membrane/epiretinal membrane peeling. Main outcome measures included distance visual acuity, near visual acuity, amplitude of P50 and N95 of the pattern electroretinogram, and fundus autofluorescence; these were assessed preoperatively, at 6 months (n = 21) and 12 months (n = 10) postoperatively. Results: There was a statistically significant improvement in distance visual acuity, near visual acuity, P50, and N95 amplitude at 6 months and 12 months postoperatively. The mean logarithm of the minimum angle of resolution distance visual acuity and near visual acuity improved from baseline by 0.31 (SD 0.37) and 0.17 (SD 0.31) at 6 months, respectively, and by 0.4 (SD 0.25) and 0.35 (SD 0.28) at 12 months, respectively. The mean P50 and N95 component amplitudes improved by 28% compared with baseline at 6 months (P50 0.4 [SD 0.8]; N95 0.53 [SD 1.07]) and by 63% at 12 months (P50 0.9 [0.85]; N95 1.04 [1.34]). Autofluorescence did not demonstrate damage to the retinal pigment epithelium attributable to TB. Conclusion: No deleterious effects of TB were observed in this study. Copyright © 2011 Lippincott Williams &Wilkins.
Resumo:
The urinary catheter is a thin plastic tube that has been designed to empty the bladder artificially, effortlessly, and with minimum discomfort. The current CH14 male catheter design was examined with a view to optimizing the mass flow rate. The literature imposed constraints to the analysis of the urinary catheter to ensure that a compromise between optimal flow, patient comfort, and everyday practicality from manufacture to use was achieved in the new design. As a result a total of six design characteristics were examined. The input variables in question were the length and width of eyelets 1 and 2 (four variables), the distance between the eyelets, and the angle of rotation between the eyelets. Due to the high number of possible input combinations a structured approach to the analysis of data was necessary. A combination of computational fluid dynamics (CFD) and design of experiments (DOE) has been used to evaluate the "optimal configuration." The use of CFD couple with DOE is a novel concept, which harnesses the computational power of CFD in the most efficient manner for prediction of the mass flow rate in the catheter. Copyright © 2009 by ASME.
Resumo:
This paper reports one of the first investigations to analyze inter-partner perceptions of psychic distance between two countries. Its empirical focus is British and Indian SMEs engaged in business with each other. It examines different dimensions of psychic distance, their impact and modes of coping with them. Potential firm-level and individual influences are also taken into account. The paper aims to transcend some of the conceptual and methodological limitations of previous research on the subject and to identify the theoretical and practical implications that arise. A ‘mirror’ approach is applied, accessing both partners’ perceptions. These are assessed through a ‘mixed’ method combining quantitative measurement with qualitative interpretations. Psychic distance dimensions are found to vary in their impact on doing business with the other country, and there is also variation according to the firm’s sector. There is considerable asymmetry in British and Indian partners’ perceptions of psychic distance but the degree of difference between their psychic distance evaluations lacks predictive power. Culturally embedded psychic distance dimensions tend to have less impact and to be easier to cope with than institutionally embedded dimensions. Four categories of coping are identified. The principal theoretical implication of this study is that a contingency perspective needs to be adopted in the field of ‘distance’ research, taking account of factors such as a firm’s sector, and that this will require a more complex analytical framework that hitherto.
Resumo:
This mixed methods study investigated language learning motivation in an one-year e-learning course for technological university students to bridge the geographical divide between students on industrial placements when studying graded readers using an e-learning course to improve their English competence and to pass the General English Proficiency Test. Data was collected through questionnaires and course feedback. The results of this study extend Gardner’s socio-educational model in an e-learning environment by adding the new category, Computer Attitudes, which was proven to be highly correlated with Motivation. Although the low proficiency English students had good computer skills, their habits of using the computer for entertainment and their lack of the skill of “technological communication efficacy” caused increased anxiety when using computers and thus provided them with a lower computer confidence over time. Consequently, it is recommended that sound e-learning training should be provided to all of the students prior to embarking on an e-leaning course so that these learners can benefit from online language learning in the future.
Resumo:
This study uses a discrete choice experiment (DCE) to elicit willingness to pay estimates for changes in the water quality of three rivers. As many regions the metropolitan region Berlin-Brandenburg struggles to achieve the objectives of the Water Framework Directive until 2015. A major problem is the high load of nutrients. As the region is part of two states (Länder) and the river sections are common throughout the whole region we account for the spatial context twofold. Firstly, we incorporate the distance between each respondent and all river stretches in all MNL and RPL models, and, secondly, we consider whether respondents reside in the state of Berlin or Brandenburg. The compensating variation (CV) calculated for various scenarios shows that overall people would significantly benefit from improved water quality. The CV measures, however, also reveal that not considering the spatial context would result in severely biased welfare measures. While the distance decay effect lowers CV, state residency is connected to the frequency of status quo choices and not accounting for residency would underestimate possible welfare gains in one state. Another finding is that the extent of the market varies with respect to attributes (river stretches) and attribute levels (water quality levels).
Resumo:
Purpose: To describe associations between reticular pseudodrusen, individual characteristics, and retinal function.
Design: Cohort study.
Participants: We recruited 105 patients (age range, 52–93 years) who had advanced neovascular age-related macular degeneration (AMD) in only 1 eye from 3 clinical centers in Europe.
Methods: Minimum follow-up was 12 months. The eye selected for study was the fellow eye without advanced disease. Clinical measures of vision were distance visual acuity, near visual acuity, and results of the Smith-Kettlewell low-luminance acuity test (SKILL). Fundus imaging included color photography, red-free imaging, blue autofluorescence imaging, fluorescein angiography, indocyanine green angiography, and optical coherence tomography using standardized protocols. These were used to detect progression to neovascular AMD in the study eye during follow-up. All imaging outputs were graded for the presence or absence of reticular pseudodrusen (RPD) using a multimodal approach. Choroidal thickness was measured at the foveal center and at 2 other equidistant locations from the fovea (1500 μm) nasally and temporally. Metrics on retinal thickness and volume were obtained from the manufacturer-supplied automated segmentation readouts.
Main Outcome Measures: Presence of RPD, distance visual acuity, near visual acuity, SKILL score, choroidal thickness, retinal thickness, and retinal volume.
Results: Reticular pseudodrusen was found in 43 participants (41%) on 1 or more imaging method. The SKILL score was significantly worse in those with reticular drusen (mean score ± standard deviation [SD, 38±12) versus those without (mean score ± SD, 33±9) (P = 0.034). Parafoveal retinal thickness, parafoveal retinal volume, and all of the choroidal thickness parameters measured were significantly lower in those with reticular drusen than in those without. The presence of RPD was associated with development of neovascular AMD when corrected for age and sex (odds ratio, 5.5; 95% confidence interval, 1.1–28.8; P = 0.042). All participants in whom geographic atrophy developed during follow-up had visible RPD at baseline.
Conclusions: Significant differences in retinal and choroidal anatomic features, visual function, and risk factor profile exist in unilateral neovascular AMD patients with RPD compared with those without; therefore, such patients should be monitored carefully because of the risk of developing bilateral disease.