113 resultados para Fecal steroids extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A series of four calix[5]arenes and three calix[6]arenes (R-calixarene-OCH2COR1) (R = H or Bu-t) with alkyl ketone residues (R-1 = Me or Bu-t) on the lower rim have been synthesized, and their affinity for complexation of alkali cations has been assessed through phase-transfer experiments and stability constant measurements. The conformations of these ketones have been probed by H-1 NMR and X-ray diffraction analysis, and by molecular mechanics calculations. Pentamer 3 (R R-1 = Bu-t) possesses a symmetrical cone conformation in solution and a very distorted cone conformation in the solid state. Pentamer 5 (R = H, R-1 = Bu-t) exists in a distorted 1,2-alternate conformation in the solid state, but in solution two slowly interconverting conformations, one a cone and the other presumed to be 1,2-alternate, can be detected. X-ray structure analysis of the sodium and rubidium perchlorate complexes of 3 reveal the cations deeply encapsulated by the ethereal and carbonyl oxygen atoms in distorted cone conformations which can be accurately reproduced by molecular mechanics calculations. The phase-transfer and stability constant data reveal that the extent of complexation depends on calixarene size and the nature of the alkyl residues adjacent to the ketonic carbonyls with tert-butyl much more efficacious than methyl.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ionic liquid 1-ethyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl}amide ([C(2)mim][NTf2]) was tested as solvent for the separation of aromatic and aliphatic hydrocarbons containing 7 or 8 carbon atoms (the C-7- and C-8-fractions). The liquid-liquid equilibria (LLE) of the ternary systems (heptane + toluene + [C(2)mim][NTf2]) and (octane + ethylbenzene + [C(2)mim][NTf2]), at 25 degrees C, were experimentally determined. The performance of the ionic liquid as the solvent in such systems was evaluated by means of the calculation of the solute distribution ratio and the selectivity. The results were compared to those previously reported for the extraction of benzene from its mixtures with hexane by using the same ionic liquid, therefore analysing the influence of the size of the hydrocarbons. It was found that the ionic liquid is also good for the extraction of C-7- and C-8- fraction aromatic compounds, just a greater amount of ionic liquid being needed to perform an equivalently efficient separation than for the C-6-fraction. It is also discussed how [C(2)mim][NTf2] performs comparably better than the conventional solvent sulfolane. The original 'Non-Random Two-Liquid' (NRTL) equation was used to adequately correlate the experimental LLE data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study the extraction of paralytic shellfish poisoning (PSP) toxins from a toxic strain of the marine dinoflagellate Alexandrium tamarense CCMP-1493 using various mechanical and/or physical procedures was investigated. PBS buffer was investigated as the extraction solvent in order for these procedures to be used directly with immuno-magnetic Ferrospheres-N. The extraction was performed following the determination of when toxin content by the algae was at its highest during batch culture. The methods used for cell lysis and toxin extraction included freeze-thawing, freeze-boiling, steel ball bearing beating, glass bead beating, and sonication. The steel ball bearing beating was determined to release a similar amount of toxin when compared to a modified standard extraction method which was reported to release 100% of toxins from the algal cells and was therefore used in the next phase of the study. This next phase was to determine the feasibility of utilising an antibody coupled to novel magnetic microspheres (Ferrospheres-N) as a simple, rapid immune-capture procedure for PSP toxins extracted from the algae. The effects of increasing mass of Ferrospheres-N on the immuno-capture of the PSP toxins from the toxic algal strain extracts were investigated. Toxin recovery was found to increase when an increasing mass of Ferrospheres-N was used until 96.2% (+/- 1.3 SD) of the toxin extracted from the cells was captured and eluted. Toxin recovery was determined by comparison to an appropriate PSP toxin standard curve following analysis by the AOAC HPLC method. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capillary micro reactor, with four stable operating flow patterns and a throughput range from grams per hour to kilograms per hour, presents an attractive alternative to chip-based and microstructured reactors for laboratory- and pilot-scale applications. In this article, results for the extraction of 2-butanol from toluene under different flow patterns in a water/toluene flow in long capillary microreactors are presented. The effects of the capillary length (0.4-2.2 m), flow rate (0.1-12 mL/min), and aqueous-to-organic volumetric flow ratio (0.25-9) on the slug, bubbly, parallel, and annular flow hydrodynamics were investigated. Weber-number-dependent flow maps were composed for capillary lengths of 0.4 and 2 m that were used to interpret the flow pattern formation in terms of surface tension and inertia forces. When the capillary length was decreased from 2 to 0.4 m, a transition from annular to parallel flow was observed. The capillary length had little influence on slug and bubbly flows. The flow patterns were evaluated in terms of stability, surface-to-volume ratio, throughput, and extraction efficiency. Slug and bubbly flow operations yielded 100% thermodynamic extraction efficiency, and increasing the aqueous-to-organic volumetric ratio to 9 allowed for 99% 2-butanol extraction. The parallel and annular flow operating windows were limited by the capillary length, thus yielding maximum 2-butanol extractions of 30% and 47% for parallel and annular flows, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A surface plasmon resonance (SPR) biosensor screening assay was developed and validated to detect 11 benzimidazole carbamate (BZT) veterinary drug residues in milk. The polyclonal antibody used was raised in sheep against a methyl 5(6)-[(carboxypentyl)-thio]-2-benzimidazole carbamate protein conjugate. A sample preparation procedure was developed using a modified QuEChERS method. BZT residues were extracted from milk using liquid extraction/partition with a dispersive solid phase extraction clean-up step. The assay was validated in accordance with the performance criteria described in 2002/657/EC. The limit of detection of the assay was calculated from the analysis of 20 known negative milk samples to be 2.7 mu g kg(-1). The detection capability (CC beta) of the assay was determined to be 5 mu g kg(-1) for 11 benzimidazole residues and the mean recovery of analytes was in the range 81-116%. A comparison was made between the SPR-biosensor and UPLC-MS/MS analyses of milk samples (n = 26) taken from cows treated different benzimidazole products, demonstrating the SPR-biosensor assay to be fit for purpose. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunoaffinity chromatography (IAC) and affinity chromatography (AC:) are widely used for extraction of drugs from biological samples. Fifteen column types were purchased from five different manufacturers and;their ability to bind specific drugs including beta-agonists and anabolic steroids over a range of analyte concentrations in fortified bovine urine samples was assessed. The performance data obtained from these columns were compared with columns produced in this laboratory (in house columns). The in house columns gave the highest recoveries, ranging from 92 to 100% at the 1 ng spiking concentration, for five of the seven analytes assessed. Forty percent (11 of 27) of all the commercial column assessments recorded recoveries of less than 50% even when the lowest spiking concentration was applied (1 ng). For one manufacturer, only one of seven different columns purchased delivered extraction efficiencies greater than 50%. The extraction efficiencies of the clenbuterol columns were the highest with all commercially prepared columns showing at least 50% binding of radiolabelled tracer. Recoveries of alpha-nortestosterone were the lowest. The variability of these products with respect to quality control requires constant monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of three conventional enzyme and radioimmunoassays routinely used to detect residues of anabolic steroids in cattle sera were compared with dissociation enhanced lanthanide fluorescence immunoassay (DELFIA) kits designed for the hospital market. Slight modifications to the kit reagents were required for the analysis of bovine sera. Owing to the large sample volumes used in conventional assays, detection limits were generally better than those obtained with DELFIA kits, however, assay reproducibility was enhanced using the DELFIA technology. Comparison of sera obtained from cattle implanted with anabolic steroids revealed a good correlation between alternate methods (r(2) from 0.91 to 0.97). The DELFIA kits offer a faster method for measuring estradiol, progesterone and testosterone with adequate sensitivity and in a safer environment than that encountered using radioimmunoassays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r=0.9999) over a concentration range of 100-2000 ng mL(-1). SBSE showed consistent recoveries (similar to 70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL(-1) and 36.37 ng mL(-1), respectively, however, for the experimental purposes, 100 ngmL(-1) was considered as the validated LOQ(accuracy and precision at this LQC was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser plasma interferograms are currently analyzed by extraction of the phase-shift map with fast Fourier transform (FFT) techniques [Appl. Opt. 18, 3101 (1985)]. This methodology works well when interferograms are only marginally affected by noise and reduction of fringe visibility, but it can fail to produce accurate phase-shift maps when low-quality images are dealt with. We present a novel procedure for a phase-shift map computation that makes extensive use of the ridge extraction in the continuous wavelet transform (CWT) framework. The CWT tool is flexible because of the wide adaptability of the analyzing basis, and it can be accurate because of the intrinsic noise reduction in the ridge extraction. A comparative analysis of the accuracy performances of them new tool and the FFT-based one shows that the CWT-based tool produces phase maps considerably less noisy and that it can better resolve local inhomogeneties. (C) 2001 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapidly increasing number of Web databases are now become accessible via
their HTML form-based query interfaces. Query result pages are dynamically generated
in response to user queries, which encode structured data and are displayed for human
use. Query result pages usually contain other types of information in addition to query
results, e.g., advertisements, navigation bar etc. The problem of extracting structured data
from query result pages is critical for web data integration applications, such as comparison
shopping, meta-search engines etc, and has been intensively studied. A number of approaches
have been proposed. As the structures of Web pages become more and more complex, the
existing approaches start to fail, and most of them do not remove irrelevant contents which
may a®ect the accuracy of data record extraction. We propose an automated approach for
Web data extraction. First, it makes use of visual features and query terms to identify data
sections and extracts data records in these sections. We also represent several content and
visual features of visual blocks in a data section, and use them to ¯lter out noisy blocks.
Second, it measures similarity between data items in di®erent data records based on their
visual and content features, and aligns them into di®erent groups so that the data in the
same group have the same semantics. The results of our experiments with a large set of
Web query result pages in di®erent domains show that our proposed approaches are highly
e®ective.