104 resultados para |Nested-PCR


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate the application of a commercially available multiplex reverse transcription polymerase chain reaction (RT-PCR) assay [He-mavision-7 System] for the seven most common leukemia translocations for routine molecular diagnostic hematopathology practice. A total of 98 samples, comprising four groups, were evaluated: Group 1, 16 diagnostic samples molecularly positive by our existing laboratory-developed assays for PML-RARalpha/t (15; 17) or BCR-ABL/t (9;22); Group 2, 51 diagnostic samples negative by our laboratory-developed assays for PML-RARalpha/t (15;17) or BCR-ABL/t (9;22); Group 3, 21 prospectively analyzed diagnostic cases, without prior molecular studies; and Group 4, 10 minimal residual disease (MRD) samples. Analysis of the two previously studied cohorts (Groups 1 and 2) confirmed the diagnostic sensitivity and specificity of the multiplex assay with regard to these two translocations. Additionally, however, in the

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a quick PCR-based method to distinguish European cryptic Myotis spp., Myotis mystacinus, Myotis brandtii and Myotis alcathoe is described. Primers were designed around species-specific single nucleotide polymorphisms (SNPâs) in the ND1 mitochondrial gene, and a pair of control primers was designed in the 12S mitochondrial gene. A multiplex of seven primer combinations produces clear species-specific bands using gel electrophoresis. Robustness of the method was tested on 33 M. mystacinus, 16 M. brandtii and 15 M. alcathoe samples from across the European range of these species. The method worked well on faecal samples collected from maternity roosts of M. mystacinus. The test is intended to aid collection of data on these species through a rapid and easy identification method with the ability to use DNA obtained from a range of sources including faecal matter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a need to provide rapid, sensitive, and often high throughput detection of pathogens in diagnostic virology. Viral gastroenteritis is a serious health issue often leading to hospitalization in the young, the immunocompromised and the elderly. The common causes of viral gastroenteritis include rotavirus, norovirus (genogroups I and II), astrovirus, and group F adenoviruses (serotypes 40 and 41). This article describes the work-up of two internally controlled multiplex, probe-based PCR assays and reports on the clinical validation over a 3-year period, March 2007 to February 2010. Multiplex assays were developed using a combination of TaqMan⢠and minor groove binder (MGBâ¢) hydrolysis probes. The assays were validated using a panel of 137 specimens, previously positive via a nested gel-based assay. The assays had improved sensitivity for adenovirus, rotavirus, and norovirus (97.3% vs. 86.1%, 100% vs. 87.8%, and 95.1% vs. 79.5%, respectively) and also more specific for targets adenovirus, rotavirus, and norovirus (99% vs. 95.2%, 100% vs. 93.6%, and 97.9% vs. 92.3%, respectively). For the specimens tested, both assays had equal sensitivity and specificity for astrovirus (100%). Overall the probe-based assays detected 16 more positive specimens than the nested gel-based assay. Post-introduction to the routine diagnostic service, a total of 9,846 specimens were processed with multiplex 1 and 2 (7,053 pediatric, 2,793 adult) over the 3-year study period. This clinically validated, probe-based multiplex testing algorithm allows highly sensitive and timely diagnosis of the four most prominent causes of viral gastroenteritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ectrodactyly-ectodermal dysplasiaclefting syndrome is a rare autosomal dominant disorder caused by heterozygous mutations in the p63 gene, a transcription factor belonging to the p53 family. The majority of cases of ectrodactyly-ectodermal dysplasia syndrome are caused by de novo mutations and are therefore sporadic in approximately 60% of patients. The substitution of arginine to histidine (R279H), due to a c.836G>A mutation in exon 7 of the p63 gene, represents 55% of the identified mutations and is considered a mutational hot spot. A quantitative and sensitive real-time PCR was performed to quantify both wild-type and R279H alleles in DNA extracted from peripheral blood and RNA from cultured epithelial cells. Standard curves were constructed for both wild-type and mutant probes. The sensitivity of the assay was determined by generating serial dilutions of the DNA isolated from heterozygous patients (50% of alleles mutated) with wild-type DNA, thus obtaining decreasing percentages of p63 R279H mutant allele (50%, 37.5%, 25%, 12.5%, 10%, 7.5%, 5%, 2.5%, and 0.0%). The assay detected up to 1% of the mutant p63. The high sensitivity of the assay is of particular relevance to prenatal diagnosis and counseling and to detect therapeutic effects of drug treatment or gene therapy aimed at reducing the amount of mutated p63. © 2012 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

<p>Background: The relationship between use of proton pump inhibitors (PPIs) and histamine-2-receptor antagonists (H<sub>2</sub>RAs) and pancreatic cancer risk has yet to be examined. Data from a range of studies suggest biologically plausible mechanisms, whereby these drugs (or the conditions for which they are prescribed) may affect pancreatic cancer risk. The objective of this study was to investigate the relationship between use of PPIs/H<sub>2</sub>RAs and pancreatic cancer risk.</p><p>Methods: A nested case â control study was conducted within the UK general practice research database (GPRD). Cases had a diagnosis of exocrine pancreatic cancer and controls were matched to cases on general practice site, sex and year of birth. Exposure to PPIs and to H<sub>2</sub>RAs since entry into GPRD until 2 years before the diagnosis date (corresponding date in controls) and in the 5 years before the diagnosis date were separately assessed. Conditional logistic regression analyses were used to generate odds ratios (ORs) and 95% confidence intervals (CIs) associated with PPI or H<sub>2</sub>RA use compared with nonuse.</p><p>Results: Ever use of PPIs since entry into the GPRD (excluding the 2 years prior to diagnosis) was not associated with risk of pancreatic cancer; OR (95% CI) 1.02 (0.85 â 1.22). Neither the dose nor the duration of PPI or H<sub>2</sub>RA use was associated with pancreatic cancer risk. No consistent patterns of association were seen when cumulative exposure (dose and duration) to these drugs was examined separately or together.</p><p>Conclusion: PPI/H<sub>2</sub>RA use, in a UK population, was not associated with pancreatic cancer risk.</p>

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design is described of a double layer frequency selective surface which can produce a differential phase shift of 180 ° as the wave propagates through it at normal incidence. The hand of an applied circularly polarized signal is reversed due to the 180° phase shift, and it is demonstrated that the exit circularly polarized output signal can be phase advanced or phase retarded by 180 ° upon rotation of the elements comprising the structure. This feature allows the surface to act as a spatial phase shifter. In this paper the beam steering capabilities of a 10 à 10 array of such elements are demonstrated. Here the individual elements comprising the array are rotated relative to each other in order to generate a progressive phase shift. At normal incidence the 3 dB Axial Ratio Bandwidth for LHCP to RHCP conversion is 5.3% and the insertion loss was found to be -2.3 dB, with minimum axial ratio of 0.05 dB. This array is shown to be able to steer a beam from -40 ° to +40 ° while holding axial ratio at the pointing angle to below 4 dB. The measured radiation patterns match the theoretical calculation and full-wave simulation results. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

False-positive PCR results usually occur as a consequence of specimen-to-specimen or amplicon-to-specimen contamination within the laboratory. Evidence of contamination at time of specimen collection linked to influenza vaccine administration in the same location as influenza sampling is described. Clinical, circumstantial and laboratory evidence was gathered for each of five cases of influenza-like illness (ILI) with unusual patterns of PCR reactivity for seasonal H1N1, H3N2, H1N1 (2009) and influenza B viruses. Two 2010 trivalent influenza vaccines and environmental swabs of a hospital influenza vaccination room were also tested for influenza RNA. Sequencing of influenza A matrix (M) gene amplicons from the five cases and vaccines was undertaken. Four 2009 general practitioner (GP) specimens were seasonal H1N1, H3N2 and influenza B PCR positive. One 2010 GP specimen was H1N1 (2009), H3N2 and influenza B positive. PCR of 2010 trivalent vaccines showed high loads of detectable influenza A and B RNA. Sequencing of the five specimens and vaccines showed greatest homology with the M gene sequence of Influenza A/Puerto Rico/8/1934 H1N1 virus (used in generation of influenza vaccine strains). Environmental swabs had detectable influenza A and B RNA. RNA detection studies demonstrated vaccine RNA still detectable for at least 66 days. Administration of influenza vaccines and clinical sampling in the same room resulted in the contamination with vaccine strains of surveillance swabs collected from patients with ILI. Vaccine contamination should therefore be considered, particularly where multiple influenza virus RNA PCR positive signals (e.g. H1N1, H3N2 and influenza B) are detected in the same specimen.