71 resultados para spine motion segment stiffness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is well known that context influences our perception of visual motion direction. For example, spatial and temporal context manipulations can be used to induce two well-known motion illusions: direction repulsion and the direction after-effect (DAE). Both result in inaccurate perception of direction when a moving pattern is either superimposed on (direction repulsion), or presented following adaptation to (DAE), another pattern moving in a different direction. Remarkable similarities in tuning characteristics suggest that common processes underlie the two illusions. What is not clear, however, is whether the processes driving the two illusions are expressions of the same or different neural substrates. Here we report two experiments demonstrating that direction repulsion and the DAE are, in fact, expressions of different neural substrates. Our strategy was to use each of the illusions to create a distorted perceptual representation upon which the mechanisms generating the other illusion could potentially operate. We found that the processes mediating direction repulsion did indeed access the distorted perceptual representation induced by the DAE. Conversely, the DAE was unaffected by direction repulsion. Thus parallels in perceptual phenomenology do not necessarily imply common neural substrates. Our results also demonstrate that the neural processes driving the DAE occur at an earlier stage of motion processing than those underlying direction repulsion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we present an inertial-sensor-based monitoring system for measuring the movement of human upper limbs. Two wearable inertial sensors are placed near the wrist and elbow joints, respectively. The measurement drift in segment orientation is dramatically reduced after a Kalman filter is applied to estimate inclinations using accelerations and turning rates from gyroscopes. Using premeasured lengths of the upper and lower arms, we compute the position of the wrist and elbow joints via a proposed kinematic model. Experimental results demonstrate that this new motion capture system, in comparison to an optical motion tracker, possesses an RMS position error of less than 0.009 m, with a drift of less than 0.005 ms-1 in five daily activities. In addition, the RMS angle error is less than 3??. This indicates that the proposed approach has performed well in terms of accuracy and reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From perspective of structure synthesis, certain special geometric constraints, such as joint axes intersecting at one point or perpendicular to each other, are necessary in realizing the end-effector motion of kinematically decoupled parallel manipulators (PMs) along individual motion axes. These requirements are difficult to achieve in the actual system due to assembly errors and manufacturing tolerances. Those errors that violate the geometric constraint requirements are termed “constraint errors”. The constraint errors usually are more troublesome than other manipulator errors because the decoupled motion characteristics of the manipulator may no longer exist and the decoupled kinematic models will be rendered useless due to these constraint errors. Therefore, identification and prevention of these constraint errors in initial design and manufacturing stage are of great significance. In this article, three basic types of constraint errors are identified, and an approach to evaluate the effects of constraint errors on decoupling characteristics of PMs is proposed. This approach is illustrated by a 6-DOF PM with decoupled translation and rotation. The results show that the proposed evaluation method is effective to guide design and assembly.