46 resultados para holographic interferometry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We analyse a proposal that we have recently put forward for an interface between matter-wave and optomechanical technologies from the perspective of macroscopic quantumness. In particular, by making use of a measure of macroscopicity in quantum superpositions that is particularly well suited for continuous variables systems, we demonstrate the existence of working points for our interface at which a quantum mechanical superposition of genuinely mesoscopic states is achieved. Our proposal thus holds the potential to affirm itself as a viable atom-to-mechanics transducer of quantum coherences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-order harmonics and attosecond pulses of light can be generated when ultraintense, ultrashort laser pulses reflect off a solid-density plasma with a sharp vacuum interface, i.e., a plasma mirror. We demonstrate experimentally the key influence of the steepness of the plasma-vacuum interface on the interaction, by measuring the spectral and spatial properties of harmonics generated on a plasma mirror whose initial density gradient scale length L is continuously varied. Time-resolved interferometry is used to separately measure this scale length. 

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Naturally occurring ices lie on both interstellar dust grains and on celestial objects, such as those in the outer Solar system. These ices are continuously subjected to irradiation by ions from the solar wind and/or cosmic rays, which modify their surfaces. As a result, new molecular species may form which can be sputtered off into space or planetary atmospheres. We determined the experimental values of sputtering yields for irradiation of oxygen ice at 10 K by singly (He+, C+, N+, O+ and Ar+) and doubly (C2 +, N2 + and O2 +) charged ions with 4 keV kinetic energy. In these laboratory experiments, oxygen ice was deposited and irradiated by ions in an ultra high vacuum chamber at low temperature to simulate the environment of space. The number of molecules removed by sputtering was observed by measurement of the ice thickness using laser interferometry. Preliminary mass spectra were taken of sputtered species and of molecules formed in the ice by temperature programmed desorption (TPD). We find that the experimental sputtering yields increase approximately linearly with the projectile ion mass (or momentum squared) for all ions studied. No difference was found between the sputtering yields for singly and doubly charged ions of the same atom within the experimental uncertainty, as expected for a process dominated by momentum transfer. The experimental sputter yields are in good agreement with values calculated using a theoretical model except in the case of oxygen ions. Preliminary studies have shown molecular oxygen as the dominant species sputtered and TPD measurements indicate ozone formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spatially and temporally varying neutral, ion and electron number densities have been mapped out within laser ablated plasma plumes expanding into vacuum. Ablation of a magnesium target was performed using a KrF laser, 30 ns pulse duration and 248 nm wavelength. During the initial stage of plasma expansion (t <EQ 100 ns) interferometry has been used to obtain line averaged electron number densities, for laser power densities on target in the range 1.3 - 3.0 X 108 W/cm2. Later in the plasma expansion (t equals 1 microsecond(s) ) simultaneous absorption and laser induced fluorescence spectroscopy has been used to determine 3D neutral and ion number densities, for a power density equal to 6.7 X 107 W/cm2. Two distinct regions within the plume were identified. One is a fast component (approximately 106 cm-1) consisting of ions and neutrals with maximum number densities observed to be approximately 30 and 4 X 1012 cm-3 respectively, and the second consists of slow moving neutral material at a number density of up to 1015 cm-3. Additionally a Langmuir probe has been used to obtain ion and electron number densities at very late times in the plasma expansion (1 microsecond(s) <EQ t <EQ 15 microsecond(s) ). A copper target was ablated using a Nd:YAG laser, 7.5 ns duration and 532 nm (2 (omega) ) wavelength, with a power density on target equal to 6 X 108 W/cm2. Two regions within the plume with different velocities were observed. Within a fast component (approximately 3 X 106 cms-1) electron and ion number densities of the order 5 X 1012 cm-3 were observed and within the second slower component (approximately 106 cms-1) electron and ion number densities of the order 1 - 2 X 1013 cm-3 were determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A very fast method, cluster low-energy electron diffraction (LEED) is proposed for LEED I-V spectral analysis, in which three appproximations are introduced: the small-atom approximation, omission of the structure factors, and truncation of higher order ( > 2) scattering events. The method has been tested using a total of four sets of I-V spectra calculated by fully dynamic LEED for (i) the simple overlayer system, O on Ni{100}, and (ii) the reconstructed system, Cu on W{100}, and also one set of experimental data from W{100}-c(2 X 2)-Cu. In each case the correct structural parameters are recovered. It is suggested that for complex systems cluster LEED provides an efficient fast route to trial structures, which could be refined by automated tenser LEED.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is shown theoretically that LEED patterns from ordered overlayer systems bear a strong relationship to electron holograms, and that phase information is recorded in the diffraction intensities. It is, therefore, possible to obtain structural information by direct holographic inversion from conventional LEED I-V spectra.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

LOW-ENERGY electron diffraction (LEED) has become the most successful technique in surface crystallography1, but because of the complexity of the surface-electron scattering interactions, analyses of LEED data are still conducted on a trial-and-error basis: a direct-inversion method for treating LEED intensity data remains an attractive goal2. Building on recent theoretical and experimental developments in electron holography from surface structures3-16, we show here that three-dimensional images with atomic resolution can be obtained by a direct transform of conventional LEED intensity spectra.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By using polycapillary lenses to focus laser-produced x-ray sources to high intensities, an improvement in signal-to-noise ratio can be achieved. Here the He-alpha line emission produced by driving a titanium backlighter target is focused by a polycapillary lens and the output characterized. The x-ray spot is measured to have a peak intensity of 4.5 x 10(7) photons, with a total photon count of 8.8 x 10(8) in 0.13 +/- 0.01 mm(2). This setup is equivalent to placing the backlighter target 3 mm from the sample with a 600 mu m diameter pinhole. The polycapillary lens enables the placement of the backlighter target at a much larger distance from the sample to be studied and therefore has the ability to greatly improve the signal-to-noise ratio on detectors. We demonstrate this with two simple diffraction experiments using pyrolytic graphite and polycrystalline aluminium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports the realisation of precision surface finish (Ra 30 nm) on AISI 4340 steel using a conventional turret lathe by adapting and incorporating a surface defect machining (SDM) method [Wear, 302, 2013 (1124-1135)]. Conventional ways of machining materials are limited by the use of a critical feed rate, experimentally determined as 0.02 mm/rev, beyond which no appreciable improvement in the machined quality of the surface is obtained. However, in this research, the novel application of an SDM method was used to overcome this minimum feed rate limitation ultimately reducing it to 0.005 mm/rev and attaining an average machined surface roughness of 30 nm. From an application point of view, such a smooth finish is well within the values recommended in the ASTM standards for total knee joint prosthesis. Further analysis was done using SEM imaging, white light interferometry and numerical simulations to verify that adapting SDM method provides improved surface integrity by reducing the extent of side flow, microchips and weldments during the hard turning process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Importance: This article provides, to our knowledge, the first longitudinal population-based data on refractive error (RE) in Chinese persons.

Objective: To study cohort effects and changes associated with aging in REs among Chinese adults.

Design, Setting, and Participants: A 2-year, longitudinal population-based cohort study was conducted in southern China. Participants, identified using cluster random sampling, included residents of Yuexiu District, Guangzhou, China, aged 35 years or older who had undergone no previous eye surgery.

Methods: Participants underwent noncycloplegic automated refraction and keratometry in December 2008 and December 2010; in a random 50% sample of the participants, anterior segment ocular coherence tomography measurement of lens thickness, as well as measurement of axial length and anterior chamber depth by partial coherence laser interferometry, were performed.

Main Outcomes and Measures: Two-year change in spherical equivalent refraction (RE), lens thickness, axial length, and anterior chamber depth in the right eye.

Results: A total of 745 individuals underwent biometric testing in both 2008 and 2010 (2008 mean [SD] age, 52.2 [11.5] years; 53.7% women). Mean RE showed a 2-year hyperopic shift from −0.44 (2.21) to −0.31 (2.26) diopters (D) (difference, +0.13; 95% CI, 0.11 to 0.16). A consistent 2-year hyperopic shift of 0.09 to 0.22 D was observed among participants aged 35 to 64 years when stratifying by decade, suggesting that a substantial change in RE with aging may occur during this 30-year period. Cross-sectionally, RE increased only in the cohort younger than 50 years (0.11 D/y; 95% CI, 0.06 to 0.16). In the cross-sectional data, axial length decreased at −0.06 mm/y (95% CI, −0.09 to −0.04), although the 2-year change in axial length was positive and thus could not explain the cross-sectional difference. These latter results suggest a cohort effect, with greater myopia developing among younger persons.

Conclusions and Relevance: This first Chinese population-based longitudinal study of RE provides evidence for both important longitudinal aging changes and cohort effects, most notably greater myopia prevalence among younger persons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the repeatability and accuracy of optical biometry (Lenstar LS900 optical low-coherence reflectometry [OLCR] and IOLMaster partial coherence interferometry [PCI]) and applanation ultrasound biometry in highly myopic eyes. Setting: Division of Preventive Ophthalmology, Zhongshan Ophthalmic Center, Guangzhou, China. Design: Comparative evaluation of diagnostic technology. Methods: Biometric measurements were taken in highly myopic subjects with a spherical equivalent (SE) of -6.00 diopters (D) or higher and an axial length (AL) longer than 25.0 mm. Measurements of AL and anterior chamber depth (ACD) obtained by OLCR were compared with those obtained by PCI and applanation A-scan ultrasound. Right eyes were analyzed. Repeatability was evaluated using the coefficient of variation (CoV) and agreement, using Bland-Altman analyses. Results: The mean SE was -11.20 D ± 4.65 (SD). The CoVs for repeated AL measurements using OLCR, PCI, and applanation ultrasound were 0.06%, 0.07%, and 0.20%, respectively. The limits of agreement (LoA) for AL were 0.11 mm between OLCR and PCI, 1.01 mm between OLCR and applanation ultrasound, and 1.03 mm between PCI and ultrasound. The ACD values were 0.29 mm, 0.53 mm, and 0.51 mm, respectively. These repeatability and agreement results were comparable in eyes with extreme myopia (AL ≥27.0 mm) or posterior staphyloma. The mean radius of corneal curvature was similar between OLCR and PCI (7.66 ± 0.24 mm versus 7.64 ± 0.25 mm), with an LoA of 0.12 mm. Conclusion: Optical biometry provided more repeatable and precise measurements of biometric parameters, including AL and ACD, than applanation ultrasound biometry in highly myopic eyes. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the demographics and distribution of corneal astigmatism before cataract surgery in Chinese patients. Setting: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. Design: Clinic-based cross-sectional study. Methods: From July 2009 to May 2011, preoperative bilateral partial coherence interferometry (IOLMaster) was performed in consecutive patients having cataract surgery. Patient demographics and keratometric data were recorded. Results: The mean age of the 2849 patients (4831 eyes) was 70.56 years ± 9.55 (SD); there was a predominance of women patients (64.0%). The mean axial length was 23.58 ± 1.13 mm. The mean corneal astigmatism in this cohort was 1.01 D (range 0.05 to 6.59 D). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 25.1% of eyes, against the rule (ATR) in 58.2% of eyes, and oblique in 16.7% of eyes. The mean steep keratometry measurement was 44.76 ± 1.56 D. Against-the-rule astigmatism increased significantly with older age. Conclusions: Corneal astigmatism largely fell between 0.25 D and 1.25 D in these predominantly elderly female Chinese patients, and ATR astigmatism increased with age. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned. © 2012 ASCRS and ESCRS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Do the laws of quantum physics still hold for macroscopic objects - this is at the heart of Schrödinger’s cat paradox - or do gravitation or yet unknown effects set a limit for massive particles? What is the fundamental relation between quantum physics and gravity? Ground-based experiments addressing these questions may soon face limitations due to limited free-fall times and the quality of vacuum and microgravity. The proposed mission Macroscopic Quantum Resonators (MAQRO) may overcome these limitations and allow addressing such fundamental questions. MAQRO harnesses recent developments in quantum optomechanics, high-mass matter-wave interferometry as well as state-of-the-art space technology to push macroscopic quantum experiments towards their ultimate performance limits and to open new horizons for applying quantum technology in space. The main scientific goal is to probe the vastly unexplored ‘quantum-classical’ transition for increasingly massive objects, testing the predictions of quantum theory for objects in a size and mass regime unachievable in ground-based experiments. The hardware will largely be based on available space technology. Here, we present the MAQRO proposal submitted in response to the 4th Cosmic Vision call for a medium-sized mission (M4) in 2014 of the European Space Agency (ESA) with a possible launch in 2025, and we review the progress with respect to the original MAQRO proposal for the 3rd Cosmic Vision call for a medium-sized mission (M3) in 2010. In particular, the updated proposal overcomes several critical issues of the original proposal by relying on established experimental techniques from high-mass matter-wave interferometry and by introducing novel ideas for particle loading and manipulation. Moreover, the mission design was improved to better fulfill the stringent environmental requirements for macroscopic quantum experiments.