98 resultados para damping ratio


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Damping torque analysis is a well-developed technique for understanding and studying power system oscillations. This paper presents the applications of damping torque analysis for DC bus implemented damping control in power transmission networks in two examples. The first example is the investigation of damping effect of shunt VSC (Voltage Source Converter) based FACTS voltage control, i.e., STATCOM (Static Synchronous Compensator) voltage control. It is shown in the paper that STATCOM voltage control mainly contributes synchronous torque and hence has little effect on the damping of power system oscillations. The second example is the damping control implemented by a Battery Energy Storage System (BESS) installed in a power system. Damping torque analysis reveals that when BESS damping control is realized by regulating exchange of active and reactive power between the BESS and power system respectively, BESS damping control exhibits different properties. It is concluded by damping torque analysis that BESS damping control implemented by regulating active power is better with less interaction with BESS voltage control and more robust to variations of power system operating conditions. In the paper, all analytical conclusions obtained are demonstrated by simulation results of example power systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An energy storage system (ESS) installed in a power system can effectively damp power system oscillations through controlling exchange of either active or reactive power between the ESS and power system. This paper investigates the robustness of damping control implemented by the ESS to the variations of power system operating conditions. It proposes a new analytical method based on the well-known equal-area criterion and small-signal stability analysis. By using the proposed method, it is concluded in the paper that damping control implemented by the ESS through controlling its active power exchange with the power system is robust to the changes of power system operating conditions. While if the ESS damping control is realized by controlling its reactive power exchange with the power system, effectiveness of damping control changes with variations of power system operating condition. In the paper, an example power system installed with a battery ESS (BESS) is presented. Simulation results confirm the analytical conclusions made in the paper about the robustness of ESS damping control. Laboratory experiment of a physical power system installed with a 35kJ/7kW SMES (Superconducting Magnetic Energy Storage) was carried out to evaluate theoretical study. Results are given in the paper, which demonstrate that effectiveness of SMES damping control realized through regulating active power is robust to changes of load conditions of the physical power system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of recognising targets in non-overlapping clutter using nonlinear N-ary phase filters is addressed. Using mathematical analysis, expressions were derived for an N-ary phase filter and the intensity variance of an optical correlator output. The N-ary phase filter was shown to consist of an infinite sum of harmonic terms whose periodicity was determined by N. For the intensity variance, it was found that under certain conditions the variance was minimised due to a hitherto undiscovered phase quadrature effect. Comparison showed that optimal real filters produced greater SNR values than the continuous phase versions as a consequence of this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A design methodology to optimise the ratio of maximum oscillation frequency to cutoff frequency, f(MAX)/f(T), in 60 nm FinFETs is presented. Results show that 25 to 60% improvement in f(MAX)/f(T) at drain currents of 20-300 mu A/mu m can be achieved in a non-overlap gate-source/drain architecture. The reported work provides new insights into the design and optimisation of nanoscale FinFETs for RF applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Derivative spectroscopy has been utilised for the determination of amphotericin in various biological matrices including plasma, serum, urine and brain tissue. Whilst these methods have all been shown to be suitable for the determination of the drug in these matrices it has been reported that the application fails in the case of highly icteric plasma, this being due to the presence of high concentrations (>50 mu M) of bilirubin. This paper details the application of ratio spectra derivative spectroscopy to overcome the interference of bilirubin with amphotericin in such situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: We generate theoretical ultraviolet and extreme-ultraviolet emission line ratios for O IV and show their strong versatility as electron temperature and density diagnostics for astrophysical plasmas.
Methods: Recent fully relativistic calculations of radiative rates and electron impact excitation cross sections for O IV, supplemented with earlier data for A-values and proton excitation rates, are used to derive theoretical O IV line intensity ratios for a wide range of electron temperatures and densities.
Results: Diagnostic line ratios involving ultraviolet or extreme-ultraviolet transitions in O IV are presented, that are applicable to a wide variety of astrophysical plasmas ranging from low density gaseous nebulae to the densest solar and stellar flares. Comparisons with observational data, where available, show good agreement between theory and experiment, providing support for the accuracy of the diagnostics. However, diagnostics are also presented involving lines that are blended in existing astronomical spectra, in the hope this might encourage further observational studies at higher spectral resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for controlling wave energy converters using active bipolar damping is described and compared with current control methods. The performance of active bipolar damping is modelled numerically for two distinct types of wave energy converter and it is found that in both cases the power capture can be significantly increased relative to optimal linear damping. It is shown that this is because active bipolar damping has the potential for providing a quasi-spring or quasi-inertia, which improves the wave energy converter's tuning and amplitude of motion, resulting in the increase in power capture observed. The practical implementation of active bipolar damping is also discussed. It is noted that active bipolar damping does not require a reactive energy store and thereby reduces the cost and eliminates losses due to the cycling of reactive energy. It is also noted that active bipolar damping could be implemented using a single constant pressure double-acting hydraulic cylinder and so potentially represents a simple, efficient, robust and economic solution to the control of wave energy converters.