65 resultados para Viscosity and digestion
Resumo:
In this paper the parameters of cement grout affecting rheological behaviour and compressive strength are investigated. Factorial experimental design was adopted in this investigation to assess the combined effects of the following factors on fluidity, rheological properties, induced bleeding and compressive strength: water/binder ratio (W/B), dosage of superplasticiser (SP), dosage of viscosity agent (VA), and proportion of limestone powder as replacement of cement (LSP). Mini-slump test, Marsh cone, Lombardi plate cohesion meter, induced bleeding test, coaxial rotating cylinder viscometer were used to evaluate the rheology of the cement grout and the compressive strengths at 7 and 28 days were measured. A two-level fractional factorial statistical model was used to model the influence of key parameters on properties affecting the fluidity, the rheology and compressive strength. The models are valid for mixes with 0.35-0.42 W/B, 0.3-1.2% SP, 0.02-0.7% VA (percentage of binder) and 12-45% LSP as replacement of cement. The influences of W/B, SP, VA and LSP were characterised and analysed using polynomial regression which can identify the primary factors and their interactions on the measured properties. Mathematical polynomials were developed for mini-slump, plate cohesion meter, inducing bleeding, yield value, plastic viscosity and compressive strength as function of W/B, SP, VA and proportion of LSP. The statistical approach used highlighted the limestone powder effect and the dosage of SP and VA on the various rheological characteristics of cement grout
Resumo:
It is known that the method used to mix the liquid monomer and powder of PMMA bone cement influences the quality of the cement that is used in total joint replacements. Mixing theory indicates that the interaction between the liquid monomer and the powder is affected by a number of parameters, such as cement viscosity and degree of agitation, with this knowledge utilized in the design of cement mixing devices. Therefore, the objectives of this study were to: (i) obtain information on the interaction of the liquid monomer and the powder in the case of an PMMA bone cement, (ii) show how this knowledge can be applied to the design of an automated cement mixing device, and (iii) compare the porosity, bending modulus, and bending strength of one commercially-available cement prepared using the automated mixer and prepared using a conventional mixer that is in current clinical use. Experimental data indicated that increasing the velocity and decreasing the viscosity of the systems produced cement that improved mechanical properties, which may contribute to better mechanical integrity and, hence, reduced tendency for aseptic loosening, of cemented hip implants.
Resumo:
We present results from complementary characterizations of the primary relaxation rate of a room temperature ionic liquid (RTIL), 1-hexyl-3-methylimidazolium bis{(trifluoromethyl)sulfonyl} imide, [C(6)mim][Tf2N], over a wide temperature range. This extensive data set is successfully merged with existing literature data for conductivity, viscosity, and NMR diffusion coefficients thus providing, for the case of RTILs, a unique description of the primary process relaxation map over more than 12 decades in relaxation rate and between 185 and 430 K. This unique data set allows a detailed characterization of the VTF parameters for the primary process, that are: B = 890 K, T-0 = 155.2 K, leading to a fragility index m = 71, corresponding to an intermediate fragility. For the first time neutron spin echo data from a fully deuteriated sample of RTIL at the two main interference peaks, Q = 0.76 and 1.4 angstrom(-1) are presented. At high temperature (T > 250 K), the collective structural relaxation rate follows the viscosity behavior; however at lower temperatures it deviates from the viscosity behavior, indicating the existence of a faster process.
Resumo:
Nitrate-based NPK fertilizer was granulated in a bench scale drum granulation unit. The initial fertilizer possessed a particle size distribution similar to those in industrial granulation units. In this work, three factors are identified affecting the degree of fertilizer granulation, these are solution to solid phase ratio, the binder viscosity and the optimal rotation speed of the drum. Experimental results indicate that a critical solution to solid phase ratio is required for an increase in granulation in terms of mass median diameter. The saturated solution viscosity in this system was measured and correlated well to binder viscosity granulation theory with the critical Stokes number calculated at 700. The optimum rotation speed for flighted and unflighted drums correlated with the Froude number relationship for full scale granulation units. (C) 2000 Elsevier Science S.A. All rights reserved.
Resumo:
An electrochemical double layer capacitor test cell containing activated carbon xerogel electrodes and ionic liquid electrolyte was tested at 15, 25 and 40 OC to examine the effect of temperature on electrolyte resistance (RS) and equivalent series resistance (ESR) measured using impedance spectroscopy and capacitance using charge/discharge cycling. A commercial 10F capacitor was used as a comparison. Viscosity, ionic self-diffusion coefficients and differential scanning calorimetry measurements were used to provide an insight into the behaviour of the 1,2-dimethyl-3-propylimdazolium electrolyte. Both RS and ESR decreased with increasing temperature for both capacitors. Increasing the temperature also increased the capacitance for both the test cell and the commercial capacitor but proportionally more for the test cell. An increase in temperature decreased the ionic liquid electrolyte viscosity and increased the self diffusion coefficients of both the anion and the cation indicating an increase in dissociation and increase in ionic mobility.
Resumo:
New protic ionic liquids (PILs) based on the morpholinium, N-methylmorpholinium, and N-ethyl morpholinium cations have been synthesized through a simple and atom-economic neutralization reaction between N-alkyl morpholine and formic acid. Their densities, refractive indices, thermal properties, and electrochemical windows have been measured. The temperature dependence of their dynamic viscosity and ionic conductivity have also been determined. The results allow us to classify them according to a classical Walden diagram and to evaluate their “fragility”. In addition, morpholinium based PILs exhibit a large electrochemical window as compared to other protic ionic liquids (up 2.91 V) and possess relatively high ionic conductivities of 10-16.8 mS·cm-1 at 25 °C and 21-29 mS·cm-1 at 100 °C, and a residual conductivity close to 1.0 mS·cm-1 at -15 °C. PIL-water mixtures exhibit high ionic conductivities up to 65 mS·cm-1 at 25 °C and 120 mS·cm-1 at 100 °C for morpholinium formate with water weight fraction ww = 0.6. Morpholinium based PILs studied in this work have a low cost and low toxicity, are good ionic liquids, and prove extremely fragile. They have wide applicable perspectives as electrolytes for fuel cell devices, thermal transfer fluids, and acid-catalyzed reaction media as replacements of conventional solvents.
Resumo:
In this work, we have shown that a 100 MHz Love wave device can be used to determine whether room temperature ionic liquids (RTILs) are Newtonian fluids and have developed a technique that allows the determination of the density-viscosity product, rho eta of a Newtonian RTIL. In addition, a test for a Newtonian response was established by relating the phase change to insertion loss change. Five concentrations of a water-miscible RTIL and seven pure RTILs were measured. The changes in phase and insertion loss were found to vary linearly with the square root of the density-viscosity product for values up to (rho eta)(1/2) similar to 10 kg m(-2) s(-1/2). The square root of the density-viscosity product was deduced from the changes in either phase or insertion loss using glycerol as a calibration liquid. In both cases, the deduced values of rho eta agree well with those measured using viscosity and density meters. Miniaturization of the device, beyond that achievable with the lower-frequency quartz crystal microbalance approach, to measure smaller volumes is possible. The ability to fabricate Love wave and other surface acoustic wave sensors using planar metallization technologies gives potential for future integration into lab-on-a-chip analytical systems for characterizing ionic liquids.
Resumo:
The evaluation of exposure to aflatoxins (AF) by measurement of the level of contamination in food is hampered due to the heterogeneous distribution of AF in food. Therefore, an alternative is to estimate the exposure using specific biological markers (biomarkers) based on an understanding of the metabolism of the compound. For AF, these include aflatoxin-N-7-guanine in the urine, or AFB(1)-albumin (AF-alb) in the blood. This study assessed the level of exposure to AF in Brazilian individuals using a biomarker approach, i.e. the AF-alb adducts. Blood samples were collected from urban residents (n=50; aged 18-52) in June 1999, at the Blood Center of Antonio Carlos de Camargo Hospital, Sao Paulo, Brazil. AF-alb adduct levels were determined, by ELISA following serum albumin extraction and digestion. AF-alb adducts were detected in 31/50 (62%) samples [range 0-57.3 pg AFB(1)-lys adducts/mg of blood albumin (pg/mg)]. The mean level of positives was 14.9 pg/mg and males had the two highest levels measured (57.1 and 57.3 pg/mg). There was no correlation with age or profession. This is the first study of Brazilian, or indeed South American, individuals that has determined exposure to AF at the individual level using a biomarker approach. These levels are similar to those observed in the Philippines. These data warrant further investigation of both the sources and consequences of exposure to this potent toxin in Brazil.
Resumo:
We previously reported nonaqueous silicone elastomer gels (SEGs) for sustained vaginal administration of the CCR5-targeted entry inhibitor maraviroc (MVC). Here, we describe chemically modified SEGs (h-SEGs) in which the hydrophobic cyclomethicone component was partially replaced with relatively hydrophilic silanol-terminated polydimethylsiloxanes (st-PDMS). MVC and emtricitabine (a nucleoside reverse transcriptase inhibitor), both currently under evaluation as topical microbicides to counter sexual transmission of human immunodeficiency virus type 1 (HIV-1), were used as model antiretroviral (ARV) drugs. Gel viscosity and in vitro ARV release were significantly influenced by st-PDMS molecular weight and concentration in the h-SEGs. Unexpectedly, gels prepared with lower molecular weight grades of st-PDMS showed higher viscosities. h-SEGs provided enhanced release over 24 h compared with aqueous hydroxyethylcellulose (HEC) gels, did not modify the pH of simulated vaginal fluid (SVF), and were shown to less cytotoxic than standard HEC vaginal gel. ARV solubility increased as st-PDMS molecular weight decreased (i.e., as percentage hydroxyl content increased), helping to explain the in vitro release trends. Dye ingression and SVF dilution studies confirmed the increased hydrophilicity of the h-SEGs. h-SEGs have potential for use in vaginal drug delivery, particularly for ARV-based HIV-1 microbicides.
Resumo:
A wide range of room temperature ionic liquids based on the 3-methylpiperdinium cation core were produced from 3-methylpiperidine, which is a derivative of DYTEK® A amine. First, reaction with 1-bromoalkanes or 1-bromoalkoxyalkanes generated the corresponding tertiary amines (Rmβpip, R = alkyl or alkoxyalkyl); further quaternisation reactions with the appropriate methylating agents yielded the quaternary [Rmmβpip]X salts (X(-) = I(-), [CF3CO2](-) or [OTf](-); Tf = -SO2CF3), and [Rmmβpip][NTf2] were prepared by anion metathesis from the corresponding iodides. All [NTf2](-) salts are liquids at room temperature. [Rmmβpip]X (X(-) = I(-), [CF3CO2](-) or [OTf](-)) are low-melting solids when R = alkyl, but room temperature liquids upon introduction of ether functionalities on R. Neither of the 3-methylpiperdinium ionic liquids showed any signs of crystallisation, even well below 0 °C. Some related non-C-substituted piperidinium and pyrrolidinium analogues were prepared and studied for comparison. Crystal structures of 1-hexyl-1,3-dimethylpiperidinium tetraphenylborate, 1-butyl-3-methylpiperidinium bromide, 1-(2-methoxyethyl)-1-methylpiperidinium chloride and 1-(2-methoxyethyl)-1-methylpyrrolidinium bromide are reported. Extensive structural and physical data are collected and compared to literature data, with special emphasis on the systematic study of the cation ring size and/or asymmetry effects on density, viscosity and ionic conductivity, allowing general trends to be outlined. Cyclic voltammetry shows that 3-methylpiperidinium ionic liquids, similarly to azepanium, piperidinium or pyrrolidinium counterparts, are extremely electrochemically stable; the portfolio of useful alternatives for safe and high-performing electrolytes is thus greatly extended.
Resumo:
OBJECTIVE: To examine a panel of 28 biomarkers for prediction of cardiovascular disease (CVD) and non-CVD mortality in a population-based cohort of men.
METHODS: Starting in 1979, middle-aged men in Caerphilly underwent detailed medical examination. Subsequently 2171 men were re-examined during 1989-1993, and fasting blood samples obtained from 1911 men (88%). Fibrinogen, viscosity and white cell count (WCC), routine biochemistry tests and lipids were analysed using fresh samples. Stored aliquots were later analysed for novel biomarkers. Statistical analysis of CVD and non-CVD mortality follow-up used competing risk Cox regression models with biomarkers in thirds tested at the 1% significance level after covariate adjustment.
RESULTS: During an average of 15.4years follow-up, troponin (subhazard ratio per third 1.71, 95% CI 1.46-1.99) and B-natriuretic peptide (BNP) (subhazard ratio per third 1.54, 95% CI 1.34-1.78) showed strong trends with CVD death but not with non-CVD death. WCC and fibrinogen showed similar weaker findings. Plasma viscosity, growth differentiation factor 15 (GDF-15) and interleukin-6 (IL-6) were associated positively with both CVD death and non-CVD death while total cholesterol was associated positively with CVD death but negatively with non-CVD death. C-reactive protein (C-RP), alkaline phosphatase, gamma-glutamyltransferase (GGT), retinol binding protein 4 (RBP-4) and vitamin B6 were significantly associated only with non-CVD death, the last two negatively. Troponin, BNP and IL-6 showed evidence of diminishing associations with CVD mortality through follow-up.
CONCLUSION: Biomarkers for cardiac necrosis were strong, specific predictors of CVD mortality while many inflammatory markers were equally predictive of non-CVD mortality.
Resumo:
The prothrombin G20210A polymorphism is associated with a threefold-increased risk of venous thrombosis. There is considerable variation in the reported prevalence of this polymorphism within normal populations, ranging from 0 to 6.5%. The prevalence within the Irish population has not been determined. A restriction fragment length polymorphism (RFLP)-based assay is commonly used for the detection of the prothrombin 20210A allele. This assay does not include a control restriction digest fragment and, consequently, failure of the enzyme activity or lack of addition of enzyme to the sample cannot be distinguished from wild-type prothrombin. We developed a RFLP-based assay, which incorporates an invariant digest site, resulting in the generation of a control digest fragment. Furthermore, we developed a nested polymerase chain reaction (PCR) method for the amplification and digestion of poor-quality or low-concentration DNA. In the Irish population studied, five of 385 (1.29%) were heterozygous and one patient was homozygous for the prothrombin 20210A polymorphism. This is the first reported data on an Irish or Celtic population and suggests that the allele frequency is similar to Anglo-Saxon populations. The nested PCR method successfully amplified and digested 100/100 (100%) of the archived samples; none of these samples could be analyzed by the standard single-round PCR method. In conclusion, nested PCR should be considered in the analysis of archived samples. Single-round PCR is appropriate for recently collected samples; however, an invariant control digest site should be incorporated in RFLP-based assays to validate the integrity of the digestion enzyme and limit the risk of false-negative results.
Resumo:
The grouts used in sealing or backfilling boreholes should ideally be selected to be compatible with the insitu field instruments installed in the borehole and also be engineered to match closely the geotechnical properties of the parent soils. A stable grout can be made using cement with various proportions of bentonite. The grout stability is very important during both the liquid and set conditions. The liquid grout fluidity should be as viscous as possible to avoid segregation, yet fluid enough to be easily pumpable and fill voids and over-break in the borehole. This paper investigates the effect of bentonite on the fresh and rheological properties of cement-based grouts in order to develop a stable grout to be used in these geotechnical situations. These properties were evaluated by the mini-slump flow, marsh cone flow time, Lombardi plate cohesion meter, static bleeding, yield stress and plastic viscosity values. Additionally, the compressive strength at 3 days, 7 days and 28 days were also investigated. The key parameters investigated were the dosages of bentonite and water-to-binder ratio (W/B). Test results showed that the dosage of bentonite had a significant effect on the fluidity, rheological properties and compressive strength of grout. The increase in the dosage of bentonite led to increasing the values of flow time, plate cohesion meter, yield stress and plastic viscosity, and reducing the mini-slump results, the static bleeding and the compressive strength at 3 days, 7 days and 28 days. Conversely, the increase in W/B led to decreasing the values of flow time, plate cohesion meter, yield stress, and plastic viscosity and the compressive strength, while increasing the mini-slump results and bleeding. Some recommendations for suitable mix proportions for use in soil boreholes are made.
Resumo:
Since the observation of the first brown dwarf in 1995, numerous studies have led to a better understanding of the structures of these objects. Here we present a method for studying material resistivity in warm dense plasmas in the laboratory, which we relate to the microphysics of brown dwarfs through viscosity and electron collisions. Here we use X-ray polarimetry to determine the resistivity of a sulphur-doped plastic target heated to Brown Dwarf conditions by an ultra-intense laser. The resistivity is determined by matching the plasma physics model to the atomic physics calculations of the measured large, positive, polarization. The inferred resistivity is larger than predicted using standard resistivity models, suggesting that these commonly used models will not adequately describe the resistivity of warm dense plasma related to the viscosity of brown dwarfs.
Resumo:
Ultrasound absorption spectra of four 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide were determined as a function of the alkyl chain length on the cation from 1-propyl- to 1-hexyl- from 293.15 to 323.15 K at ambient pressure. Herein, the ultrasound absorption measurements were carried out using a standard pulse technique within a frequency range from 10 to 300 MHz. Additionally the speed of sound, density and viscosity have been measured. The presence of strong dissipative processes during the ultrasound wave propagation was found experimentally, i.e. relaxation processes in the megahertz range were observed for all compounds over the whole temperature range. The relaxation spectra (both relaxation amplitude and relaxation frequency) were shown to be dependent on the alkyl side chain length of the 1-alkyl-3-methylimidazolium ring. In most cases, a single Debye model described the absorption spectra very well. However, a comparison of the determined spectra with the spectra of a few other imidazolium-based ionic liquids reported in the literature (in part recalculated in this work) shows that the complexity of the spectra increases rapidly with the elongation of the alkyl chain length on the cation. This complexity indicates that both the volume viscosity and the shear viscosity are involved in relaxation processes even in relatively low frequency ranges. As a consequence, the sound velocity dispersion is present at relatively low megahertz frequencies.