106 resultados para Surface Plasmon, Impedance Spectroscopy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

DNA sequences attached to Au nanoparticles via thiol linkers stand up from the surface, giving preferential enhancement of the adenine ring breathing SERS band. Non-specific binding via the nucleobases reorients the DNA, reducing this effect. This change in intensity on reorientation was utilised for label-free detection of hybridization of a molecular beacon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Singles only: DNA sequences can be induced to spontaneously adsorb to the surfaces of Ag colloids through their nucleotide side chains (see picture). The SERS spectra of these nonspecifically bound strands are sufficiently reproducible that they can be used to identify single-base mismatches in short (25-mer and 23-mer) strands. Subtracting the spectra of different DNA sequences results in difference spectra that contain features corresponding to the exchanged nucleotides.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polymer based carbon aerogels were prepared by synthesis of a resorcinol formaldehyde gel followed by pyrolysis at 1073K under Ar and activation of the resultant carbon under CO2 at different temperatures. The prepared carbon aerogels were used as active materials in the preparation of cathode electrodes for lithium oxygen cells and the electrochemical performance of the cells was evaluated by galvanostatic charge/discharge cycling and electrochemical impedance measurements. It was shown that the storage capacity and discharge voltage of a Li/O2 cell strongly depend on the porous structure of the carbon used in cathode. EIS results also showed that the shape and value of the resistance in the impedance spectrum of a Li/O2 cell are strongly affected by the porosity of carbon used in the cathode. Porosity changes due to the build up of discharge products hinder the oxygen and lithium ion transfer into the electrode, resulting in a gradual increase in the cell impedance with cycling. The discharge capacity and cycle life of the battery decrease significantly as its internal resistance increases with charge/discharge cycling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Paralytic shellfish poisoning (PSP) toxins are produced by certain marine dinoflagellates and may accumulate in bivalve molluscs through filter feeding. The Mouse Bioassay (MBA) is the internationally recognised reference method of analysis, but it is prone to technical difficulties and regarded with increasing disapproval due to ethical reasons. As such, alternative methods are required. A rapid surface plasmon resonance (SPR) biosensor inhibition assay was developed to detect PSP toxins in shellfish by employing a saxitoxin polyclonal antibody (R895). Using an assay developed for and validated on the Biacore Q biosensor system, this project focused on transferring the assay to a high-throughput, Biacore T100 biosensor in another laboratory. This was achieved using a prototype PSP toxin kit and recommended assay parameters based on the Biacore Q method. A monoclonal antibody (GT13A) was also assessed. Even though these two instruments are based on SPR principles, they vary widely in their mode of operation including differences in the integrated mu-fluidic cartridges, autosampler system, and sensor chip compatibilities. Shellfish samples (n = 60), extracted using a simple, rapid procedure, were analysed using each platform, and results were compared to AOAC high performance liquid chromatography (HPLC) and MBA methods. The overall agreement, based on statistical 2 x 2 comparison tables, between each method ranged from 85% to 94.4% using R895 and 77.8% to 100% using GT13A. The results demonstrated that the antibody based assays with high sensitivity and broad specificity to PSP toxins can be applied to different biosensor platforms. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Saxitoxin and its analogs, the causative agents of paralytic shellfish poisoning (PSP), are a worldwide threat to seafood safety. Effective monitoring of potentially contaminated fishing areas as well as screening of seafood samples is necessary to adequately protect the public. While many analytical methods exist for detecting paralytic shellfish toxins (PSTs), each technique has challenges associated with routine use. One recently developed method [1] that overcomes ethical or performance-related issues of other techniques is the surface plasmon resonance (SPR) bioassay. Notwithstanding the advantages of this method, much research remains in optimizing the sensor substrate and assay conditions to create a robust technique for rapid and sensitive measurement of PSTs. This manuscript describes a more rigorous and stable SPR inhibition immunoassay through optimization of the surface chemistry as well as determination of optimum mixture ratios and mixing times. The final system provides rapid substrate formation (18 h saxitoxin conjugation with low reagent consumption), contains a reference channel for each assay, and is capable of triplicate measurements in a single run with detection limits well below the regulatory action level. Published by Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A surface plasmon resonance (SPR) optical biosensor method was developed for the detection of paralytic shellfish poisoning (PSP) toxins in shellfish. This application was transferred in the form of a prototype kit to seven laboratories using Biacore QSPR optical biosensor instrumentation for interlaboratory evaluation. Each laboratory received 20 shellfish samples across a range of species including blind duplicates for analysis. The samples consisted of 4 noncontaminated samples spiked in duplicate with a low level of PSP toxins (240 mu g STXcliHCl equivalents/kg), a high level of saxitoxin (825 mu g STXdiHCl/kg), 2 noncontarninated, and 14 naturally contaminated samples. All 7 participating laboratories completed the study, and HorRat values obtained were

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unlabelled single- and double-stranded DNA (ssDNA and dsDNA, respectively) has been detected at concentrations =10-9?M by surface-enhanced Raman spectroscopy. Under appropriate conditions the sequences spontaneously adsorbed to the surface of both Ag and Au colloids through their nucleobases; this allowed highly reproducible spectra with good signal-to-noise ratios to be recorded on completely unmodified samples. This eliminated the need to promote absorption by introducing external linkers, such as thiols. The spectra of model ssDNA sequences contained bands of all the bases present and showed systematic changes when the overall base composition was altered. Initial tests also showed that small but reproducible changes could be detected between oligonucleotides with the same bases arranged in a different order. The spectra of five ssDNA sequences that correspond to different strains of the Escherichia coli bacterium were found to be sufficiently composition-dependent so that they could be differentiated without the need for any advanced multivariate data analysis techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The excitation of surface plasmon-polariton (SPP) waveguide modes in subwavelength dielectric ridges deposited on a thin gold film has been characterized and optimized at telecommunication wavelengths. The experimental data on the electromagnetic mode structure obtained using scanning near-field optical microscopy have been directly compared to full vectorial three-dimensional finite element method simulations. Two excitation geometries have been investigated where SPPs are excited outside or inside the dielectric tapered region adjoint to the waveguide. The dependence of the efficiency of the SPP guided mode excitation on the taper opening angle has been measured and modeled. Single-mode guiding and strong lateral mode confinement of dielectric-loaded SPP waveguide modes have been characterized with the near-field measurements and compared to the effective-index method model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have made a comparison of (a) different surface chemistries of surface plasmon resonance (SPR) sensor chips (such as carboxymethylated dextran and carboxymethylated C1) and (b) of different assay formats (direct, sandwich and subtractive immunoassay) in order to improve the sensitivity of the determination of the model bacteria Acidovorax avenae subsp. citrulli (Aac). The use of the carboxymethylated sensor chip C1 resulted in a better sensitivity than that of carboxymethylated dextran CM5 in all the assay formats. The direct assay format, in turn, exhibits the best sensitivity. Thus, the combination of a carboxymethylated sensor chip C1 with the direct assay format resulted in the highest sensitivity for Aac, with a limit of detection of 1.6x106 CFU mL-1. This SPR immunosensor was applied to the detection of Aac in watermelon leaf extracts spiked with the bacteria, and the lower LOD is 2.2x107 CFU mL-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the direct imaging of surface plasmon propagation on thin silver films using the photon scanning tunneling microscope. It is found that the surface plasmon remains tightly confined in the original launch direction with insignificant scattering to other momentum states. A propagation length of 13.2 mum is measured at lambda = 632.8 nm. We also present images showing the interaction of a surface plasmon with the edge of the metal film supporting it. The most remarkable feature is the absence of a specularly reflected beam.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A binding protein displaying broad-spectrum cross-reactivity within the sulfonamide group was used in conjunction with a sulfonamide specific sensor chip and a surface plasmon resonance biosensor to develop a rapid broad spectrum screening assay for sulfonamides in porcine muscle. Results for 40 samples were available in just over 5 h after the completion of a simple sample preparation protocol. Twenty sulfonamide compounds were detected. Acetylated metabolites were not recognised by the binding protein. Limit of detection (mean-three times standard deviation value when n = 20) was calculated to be 16.9 ng g(-1) in tissue samples. Intra-assay precision (n = 10) was calculated at 4.3 %CV for a sample spiked at 50 ng g(-1) with sulfamethazine, 3.6 %CV for a sample spiked at 100 ng g(-1) with sulfamethazine, 7.2 %CV for a sample spiked at 50 ng g(-1) with sulfadiazine and 3.1 %CV for a sample spiked at 100 ng g-1 with sulfadiazine. Inter-assay precision (n = 3) was calculated at 9.7 %CV for a sample spiked at 50 ng g-1 with sulfamethazine, 3.8 %CV for a sample spiked at 100 ng g(-1) with sulfamethazine, 3.5 %CV for a sample spiked at 50 ng g(-1) with sulfadiazine and 2.8 %CV for a sample spiked at 100 ng g(-1) with sulfadiazine. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Colloidal gold nanoparticles (AuNPs) and precipitation of an insoluble product formed by HRP-biocatalyzed oxidation of 3,3'-diaminobenzidine (DAB) in the presence of H2O2 were used to enhance the signal obtained from the surface plasmon resonance (SPR) biosensor. The AuNPs were synthesized and functionalized with HS-OEG(3)-COOH by self assembling technique. Thereafter, the HS-OEG3-COOH functionalized nanoparticles were covalently conjugated with horseradish peroxidase (HRP) and anti IgG antibody to form an enzyme-immunogold complex. Characterizations were performed by several methods: UV-vis absorption, DLS, HR-TEM and Fr-IR. The Au-anti IgG-HRP complex has been applied in enhancement of SPR immunoassay using a sensor chip constructed by 1:9 molar ratio of HS-OEG(6)-COOH and HS-OEG(3)-OH for detection of anti-GAD antibody. As a result, AuNPs showed their enhancement as being consistent with other previous studies while the enzyme precipitation using DAB substrate was applied for the first time and greatly amplified the SPR detection. The limit of detection was found as low as 0.03 ng/ml of anti-GAD antibody (or 200 fM) which is much higher than that of previous reports. This study indicates another way to enhance SPR measurement, and it is generally applicable to other SPR-based immunoassays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A biochip based on surface plasmon resonance was fabricated to detect prostate specific antigen-a1-antichymotrypsin (PSA-ACT complex) in both HBS buffer and human serum. To reduce non-specific binding and steric hindrance effect, the chemical surface of the sensor chips was constructed by using various oligo(ethylene glycol) mixtures of different molar ratios of HS(CH2)11(OCH2CH2)6OCH2COOH and HS(CH2)11(OCH2CH2)3OH. The self-assembled monolayers were biotinylated to facilitate the immobilization of streptavidin. Using the chip surfaces, PSA-ACT complex in HBS buffer and human serum was detected at 20.7 and 47.5 ng/ml by primary immunoresponse, respectively. However, the limit of detection could be simply enhanced by a sandwich strategy to improve the sensitivity and specificity of the immunoassay. An intact PSA polyclonal antibody was used as an amplifying agent in the strategy. As a result, PSA-ACT complex concentrations as low as 10.2 and 18.1 ng/ml were found in the HBS buffer and human serum sample, respectively. The result indicates that this approach could satisfy our goal without modifying the secondary interactant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A surface plasmon resonance (SPR)-based inhibition assay method using a polyclonal anti-mouse IgM arrayed Cryptosporidium sensor chip was developed for the real-time detection of Cryptosporidium parvum oocysts. The Cryptosporidium sensor chip was fabricated by subsequent immobilization of streptavidin and polyclonal anti-mouse IgM (secondary antibody) onto heterogeneous self-assembled monolayers (SAMs). The assay consisted of the immunoreaction step between monoclonal anti-C. parvum oocyst (primary antibody) and oocysts, followed by the binding step of the unbound primary antibody onto the secondary antibody surface. It enhanced not only the immunoreaction yield of the oocysts by batch reaction but also the accessibility of analytes to the chip surface by antibody–antibody interaction. Furthermore, the use of optimum concentration of the primary antibody maximized its binding response on the chip. An inversely linear calibration curve for the oocyst concentration versus SPR signal was obtained in the range of 1×106–1×102 oocysts ml-1. The oocyst detection was also successfully achieved in natural water systems. These results indicate that the SPR-based inhibition assay using the Cryptosporidium sensor chip has high application potential for the real-time analysis of C. parvum oocyst in laboratory and field water monitoring.