197 resultados para Soft lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacterial attachment onto intraocular lenses (IOLs) during cataract extraction and IOL implantation is a prominent aetiological factor in the pathogenesis of infectious endophthalmitis. Photodynamic therapy (PDT) and photodynamic antimicrobial chemotherapy (PACT) have shown that photosensitizers are effective treatments for cancer, and in the photoinactivation of bacteria, viruses, fungi and parasites, in the presence of light. To date, no method of localizing the photocytotoxic effect of a photosensitizer at a biomaterial surface has been demonstrated. Here we show a method for concentrating this effect at a material surface to prevent bacterial colonization by attaching a porphyrin photosensitizer at, or near to, that surface, and demonstrate the principle using IOL biomaterials. Anionic hydrogel copolymers were shown to permanently bind a cationic porphyrin through electrostatic interactions as a thin surface layer. The mechanical and thermal properties of the materials showed that the porphyrin acts as a surface cross-linking agent, and renders surfaces more hydrophilic. Importantly, Staphylococcus epidermidis adherence was reduced by up to 99.0 ± 0.42% relative to the control in intense light conditions and 91.7± 5.99% in the dark. The ability to concentrate the photocytotoxic effect at a surface, together with a significant dark effect, provides a platform for a range of light-activated anti-infective biomaterial technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A contact lens is a medical device widely used as an alternative to spectacles in order to correct refractive vision problems. The evolution of polymeric biomaterials has heralded a continuous development in the materials used to produce contact lenses and maximize patient comfort and limit adverse events. Microbial keratitis (MK) is a relatively rare but potentially devastating condition associated with contact lens use, particularly with the extended wear of hydrogel lenses. It is the principal complication related to contact lens wear and the large population at risk make it a public health concern. Bacterial binding to the contact lens material is a precursor to the development of MK and is influenced by properties of the material and the bacteria. In order for bacteria to infiltrate the cornea there must be some degree of corneal damage, usually caused by trauma or hypoxia. The most recent materials available aim to allow the continuous wear of lenses while limiting corneal hypoxia, thus helping to prevent the development of MK. Limitations to the treatment of MK require that novel approaches may be necessary in order to limit bacterial adhesion to contact lens materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used XUV lasers to make absolute measurements of the photoabsorption coefficient of Al at energies just below that of the L3 absorption edge at 72.7 eV. Transmission measurements at photon energies of 53.7 and 63.3 eV have been made using Ne-like Ni and Ge XUV lasers. The XUV laser output was recorded in first and second orders using a flat-field spectrometer. Al foils with steps of various thicknesses were placed over the first order diffracted signal, while the second order diffraction was used to monitor the beam profile at each position. The transmission data agree extremely well with the original measurements at these wavelengths made by Henke and co-workers (Henke B L, Gullikson E M and Davis J C 1993 At. Data Nucl. Data Tables 54 18 1), but are in conflict with subsequent measurements which are currently in common use (Gullikson E M, Denham P, Mrowka S and Underwood J H 1994 Phys. Rev. B 49 16 283). The exact values of the absorption coefficients in this region of the spectrum have significant implications for the diagnosis of the energy and intensity output of XUV lasers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A lens antenna consisting of a double-sided 3 x 3 array of curl antennas that can convert an incident LH/RHCP signal into a transmitted LH/RHCP signal is shown to have an additional property that allows the angle of incidence of an incoming linear or circularly polarised signal to be determined. Here the angle of arrival information is obtained via a simple boresight power measurement made at the lens receive side. It is shown that an unambiguous angle of arrival information for signals arriving at up to +/- 45 degrees can be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a growing literature examining the impact of research on informing policy, and of research and policy on practice. Research and policy do not have the same types of impact on practice but can be evaluated using similar approaches. Sometimes the literature provides a platform for methodological debate but mostly it is concerned with how research can link to improvements in the process and outcomes of education, how it can promote innovative policies and practice, and how it may be successfully disseminated. Whether research-informed or research-based, policy and its implementation is often assessed on such 'hard' indicators of impact as changes in the number of students gaining five or more A to C grades in national examinations or a percentage fall in the number of exclusions in inner city schools. Such measures are necessarily crude, with large samples smoothing out errors and disguising instances of significant success or failure. Even when 'measurable' in such a fashion, however, the impact of any educational change or intervention may require a period of years to become observable. This paper considers circumstances in which short-term change may be implausible or difficult to observe. It explores how impact is currently theorized and researched and promotes the concept of 'soft' indicators of impact in circumstances in which the pursuit of conventional quantitative and qualitative evidence is rendered impractical within a reasonable cost and timeframe. Such indicators are characterized by their avowedly subjective, anecdotal and impressionistic provenance and have particular importance in the context of complex community education issues where the assessment of any impact often faces considerable problems of access. These indicators include the testimonies of those on whom the research intervention or policy focuses (for example, students, adult learners), the formative effects that are often reported (for example, by head teachers, community leaders) and media coverage. The collation and convergence of a wide variety of soft indicators (Where there is smoke …) is argued to offer a credible means of identifying subtle processes that are often neglected as evidence of potential and actual impact (… there is fire).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have focused a beam (BL3) of FLASH (Free-electron LASer in Hamburg: lambda = 13.5 nm, pulse length 15 fs, pulse energy 10-40 mu J, 5Hz) using a fine polished off-axis parabola having a focal length of 270 mm and coated with a Mo/Si multilayer with an initial reflectivity of 67% at 13.5 nm. The OAP was mounted and aligned with a picomotor controlled six-axis gimbal. Beam imprints on poly(methyl methacrylate) -PMMA were used to measure focus and the focused beam was used to create isochoric heating of various slab targets. Results show the focal spot has a diameter of

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: